background image

5+2 Day Programmable Thermostat

For single stage heating, cooling or millivolt heating systems

IMPORTANT: 

This thermostat is NOT compatible with any 120V or 240V high voltage control system.
Read and understand this manual before installation or use.

Instruction Manual

model: M6003

Low-voltage (24 V or millivolt)

system control

BY/PAR 

CANARM

Summary of Contents for M6003

Page 1: ... millivolt heating systems IMPORTANT This thermostat is NOT compatible with any 120V or 240V high voltage control system Read and understand this manual before installation or use Instruction Manual model M6003 Low voltage 24 V or millivolt system control BY PAR CANARM ...

Page 2: ...ation for the new thermostat Replacing the old thermostat Mounting the back plate Connecting the wires to the terminals Wiring diagram Setting the fan operation jumper Installing batteries Attaching the back plate Function key description LCD display Introduction Pre programmed settings Heating program Cooling program Programming operations Troubleshooting Warranty Features Installation Operation ...

Page 3: ...with built in protection for the air conditioner compressor Display and set temperature in ºC or ºF Interface with heating or air conditioning systems for automatic temperature control Low battery notification by flashing icons and Beep sound Features Package Contents M6003 Thermostat Instruction Manual This Document 2 Screws 2 Wall Anchors FOR LOW VOLTAGE CONTROL SYSTEMS DO NOT CONNECT TO HIGH VO...

Page 4: ...lock any ventilation openings of the thermostat Do not expose this thermostat to dripping or splashing Do not expose this thermostat to excess heat Do not attempt to disassemble repair or modify this thermostat THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE CANADIAN ELECTRICAL CODE IN QUEBEC THIS PRODUCT MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN The manufacturer assumes no responsibility...

Page 5: ...w This thermostat requires two AA size batteries not included to operate Ensure the batteries are installed The time and day must be set before use Flip the cover to access the function keys and switches Features Cover ...

Page 6: ...our technical assistance line HEATING COOLING SYSTEMS COMPATIBILTY Gas Standing Pilot Gas Electronic Ignition Gas Fire Boiler Some Models Gas Millivolt System Oil Fire Burners Some Models Oil Fire Furnace Electric Furnace Electric Air Conditioner Baseboard Electric Heater 120 240V Heat Pump Multi Stage equipment NOT COMPATIBLE WITH ANY 120 240 VOLT CIRCUIT Features ...

Page 7: ...eekend programs Display temperature with 0 1º resolution Only two AA size batteries not included required Built in protection timing for the air conditioner compressor If you have questions concerning the installation or programming of the thermostat please call 1 800 265 1833 for our technical assistance Tools required for installation Flathead screwdriver Masking tape Wire stripper cutter Power ...

Page 8: ...light or heat from a lamp sun fireplace or other temperature radiating objects which may cause false readings Near or in direct airflow from supply registers and return air grills Near concealed pipes and chimneys In areas with poor air circulation such as behind a door or in an alcove After choosing a location for the new thermostat you must arrange to have a heating contractor install the contro...

Page 9: ...tions and receipt Remove cover from old thermostat If it does not snap off when pulled firmly from the bottom check for a screw used to secure the cover Loosen screws holding thermostat to the wall and lift away the thermostat Disconnect wires from old thermostat or sub base As you disconnect each wire use masking tape to label them with the old terminal designation If there are only two wires the...

Page 10: ...the wall Select two appropriate mounting holes and mark the locations with a pencil If necessary use a level to make sure the thermostat is leveled Remove the back cover from the wall and drill two 3 16 inch holes in the marked screw positions Insert the wall anchors into the holes completely If necessary use a hammer to tap in lightly Mount the back cover with the two screws to the wall Make sure...

Page 11: ...als Depending on your heating cooling equipment you may need to connect 2 to 5 wires to the thermostat If your old thermostat has a C wire Please wrap it with electrician s tape as it is not used with this thermostat If you have both an Rh and Rc wires you may connect them together to the R terminal of thermostat If you are unsure of the connections or for new installation you may refer to the wir...

Page 12: ...11 Wiring Diagram Installation 2 wire hea ng W G Y R ng Relay ng Relay 3 wire hea ng Fan Relay W G Y R 4 wire hea ng cooling ng Relay Cooling Relay Fan Relay W G Y R ...

Page 13: ... the heating system not the thermostat This is the correct setting for most systems HE Use this setting for electric heating systems With this setting the thermostat will turn on the fan immediately with the heating system The jumper is pre installed in the HG position as a factory default So there is no need to change the jumper if this is the correct setting To change the jumper setting pull out...

Page 14: ... Monday 9 00 A M Note This is a one time process The temperature unit of the thermostat CANNOT be changed afterwards unless you reset the thermostat ATTACHING THE THERMOSTAT TO THE BACK COVER Line up the front face of the thermostat squarely to the mounted back plate and press it firmly in place The thermostat should snap be closed and there should not be any significant gaps or looseness between ...

Page 15: ...14 Installation ...

Page 16: ...15 Function Key Description Operation ...

Page 17: ...art time setting Only time will be shown See Figure 1 on page 20 Use AHEAD or BACK to set the current time Press SET CLOCK again Weekday will be shown See Figure 2 on page 20 Use AHEAD or BACK to set the current day Press SET CLOCK again to exit Operation ...

Page 18: ...e away from home The setting can be adjusted to minimize energy consumption PROGRAM3 EVENING This is for the time you return home and want the house at a comfortable temperature typically warmer settings during winter and cooler settings during summer PROGRAM4 NIGHT This is a sleep mode You may choose to set temperature for energy savings or comfort as desired NOTE The 4 programs for weekdays and ...

Page 19: ...1 20 5ºC 69ºF 6 00a m P1 25ºC 77ºF 6 00a m P1 25ºC 77ºF 6 00a m P2 17 5ºC 63 5ºF 8 00a m P2 17 5ºC 63 5ºF 8 00a m P2 29ºC 84ºF 8 00a m P2 29ºC 84ºF 8 00a m P3 21ºC 70ºF 5 00p m P3 21ºC 70ºF 5 00p m P3 25ºC 77ºF 5 00p m P3 25ºC 77ºF 5 00p m P4 17ºC 62 5ºF 10 00p m P4 17ºC 62 5ºF 10 00p m P4 26ºC 79ºF 10 00p m P4 26ºC 79ºF 10 00p m Programming ...

Page 20: ...ure for program 1 press PROG again to display weekday program 2 Repeat steps 2 5 for weekday programs P2 P3 and P4 for Saturday and Sunday programming Use same method to set the desired time and temperature for program 2 7 Repeat the procedures for weekday program 3 and 4 and weekend programs 1 4 See figure 4 on page 20 8 After complete setting of all 8 programs press PROGRAM to return to normal d...

Page 21: ...20 Tip Press and hold the AHEAD BACK or UP DOWN key to change the Numbers quickly Programming ...

Page 22: ...e heating and cooling systems from undesired on off sequences Sometimes there will be a delay of several minutes before the thermostat will activate the system HOLD FUNCTION This feature is to hold the thermostat at a constant temperature and disable all set programs until released Press HOLD once and use UP or DOWN button to set the desired hold temperature HOLD symbol will appear to indicate tha...

Page 23: ...For automatic control of the fan set the Fan ON AUTO switch to the AUTO position In cooling the fan starts stops with the cooling equipment In heating the fan is controlled by the heating equipment and usually starts a few minutes after the heating equipment turns on To turn on the fan manually set the Fan ON AUTO switch to the ON position the fan will run continuously to improve air ventilation T...

Page 24: ...ing is activated PRE COMFORT RECOVERY This thermostat is equipped with a Pre Comfort Recovery system that will activate the heating or cooling in advance of the actual set program time so that the room will be at the desired temperature at the start of the comfort program time It is normal for the system to be activated earlier up to hour for heating and one hour for cooling than the actual set pr...

Page 25: ...ries Set the thermostat system switch to the OFF position and have the new batteries on hand Open the thermostat by gently pulling the front of the thermostat away from the backplate Remove the old batteries and install new ones quickly Close the thermostat to its original position If new batteries are inserted within 20 seconds of removing the old ones the existing time and programs will not be c...

Page 26: ...t key Time and programs will need to be set again after a Reset SPECIFICATIONS Number of Programs Weekly 5 2 day programs with 4 programs per day Temperature display range 1ºC 37 5ºC 34ºF 99 5ºF Temperature setting range 5ºC 35ºC 41ºF 95ºF Storage temperature range 20ºC 50ºC 4ºF 122ºF Battery 2 X AA size batteries not included Programming ...

Page 27: ...me on HEAT symbol NOT flashing System switch is in the COOL or OFF position Current temperature is higher than the set temperature Press CURRENT to check current program Heating will not come on HEAT symbol flashing Check if the furnace switch and or pilot flame is turned on it may have been turned off Allow some time for the heater to heat up and the fan to activate Most heaters will heat up the ...

Page 28: ... a dated proof of purchase to the retailer from which you purchased it NOT COMPATIBLE WITH ANY 120 240 VOLT CIRCUIT CONTROL by par Canarm Customer Service number English 1 800 265 1833 Numéro du Service à la Clientèle de Canarm Français 1 800 567 2513 Made in China Imported by Importé par CONTROL by Canarm CANARM Ltd ltée 2157 Parkedale Avenue Brockville Ontario K6V 5V6 www canarm com 2012 Kelan H...

Reviews: