background image

Temperature alarm delay feature:

If dip switch #6 is placed in the UP position, the FreezeAlarm

 will delay 45

minutes during a temperature alarm only.  A temperature alarm condition must be
present for 45 minutes before unit will call out.

IMPORTANT INFORMATION

When called from a remote location using a Touch Tone™ phone, the FreezeAlarm

 will answer after five rings and

you will hear:

"Enter the security code followed by the star key."

If you enter the correct security code within 15 seconds, and the FreezeAlarm

 is not in alarm,

you will enter the main menu and hear:

"You are now in the main menu.  To review or program. . ."

If the FreezeAlarm

 is in alarm, you will hear one of the four alarm messages described in

Upon Alarm above.  The alarm message is repeated once, followed by:  "To disable
the alarm call out, press 0.  Otherwise, to return to the main menu, press 1."

Power alarm delay feature:

The power alarm delay is selectable from either 1 hour or 0 minutes.

Reset button:

The reset button on back of unit will switch the remote relay to the opposite setting.

Using FreezeAlarm

 on the

The FreezeAlarm

 does not require a dedicated phone line and can share a phone

          same phone line as telephone:

jack with a telephone by using a dual plug adapter (not included).  Caution:  The
FreezeAlarm

 will not work on a PBX  or multi-line systems, or a party line.

Phone answering machines at

To avoid unwanted long distance phone charges between the FreezeAlarm

 and a

the occupied (call to) location:

remote answering machine when you are not at home, set your answering machine
to pick up after four rings or higher and move dip switch #5 on the rear of the
FreezeAlarm

 to the UP position.  This will cause the FreezeAlarm

 to hang up after

three rings, preventing the answering machine from picking up the alarm call. Caution:
Because of normal connection delays in long distance calls, unit may hang up
before three rings are heard at call-to location. Test thoroughly!
  If dip switch #3
is in the DOWN position, the FreezeAlarm

 will hang up after ten rings.  Depending on

the length of your greeting, the answering machine may record a portion of the
alarm message.

Phone answering machines at

An answering machine normally will pick up a call before the FreezeAlarm

.  To

the same location as the

gain access to the FreezeAlarm

 when used with an answering machine, set the

          FreezeAlarm

:

answering machine's ring selector at four.  Call the FreezeAlarm's phone number
and hang up before the answering machine answers.  Call back again to accumulate 5
rings within 3 minutes and the FreezeAlarm

 will pick up your call.

Monitoring multiple Freeze

Upon alarm, the FreezeAlarm

 calls its programmed telephone numbers and

         Alarms using identification

announces the location of the alarm, with the custom message and the SECURITY

         number:

CODE as a location identification number.  This enables you to monitor and
identify an infinite number of FreezeAlarm

 locations.

Using the Remote Relay

The remote relay switch can be used to switch equipment or thermostats over

Switch:

the phone.  When the power goes out and the FreezeAlarm

 is being powered off

the battery, the relay will be in the T2 position.  Because types of equipment and
systems vary, it is strongly recommended that a licensed professional perform
the installation and wiring needed for your specific application.

Alarm Call-out:

The FreezeAlarm

 will continue to call-out with an alarm until disabled, even

if alarm conditions have been corrected.

Surge Protection:

Lightning surge protection is recommended for the telephone line and the power.

CALLING THE FREEZEALARM FROM A REMOTE LOCATION

Summary of Contents for FreezeAlarm FA-DX

Page 1: ...ings and monitor ing of any relay output system or sensor The remote switch control feature can be used to control thermostats or equipment from any Touch Tone phone additional parts and labor may be needed Features Adjustable high low temperature alarm setpoints Three telephone number call out up to 16 digits each Paging feature any or all of the call to numbers can be to a digital pager Power lo...

Page 2: ...on of the FreezeAlarm is shown You can see all of the sub menus that will be played when any of the main menu selections are pressed NOTE If the FreezeAlarm does not recognize an entry you will hear invalid entry and the menu selections will be replayed Re enter your menu selection within 15 seconds to continue with the programming sequence IMPORTANT After programming disconnect your telephone fro...

Page 3: ...eview of program the low temperature alarm set point press two To return to the main menu press three If you press 1 or 2 the high the low temperature alarm set point is now xxx degrees To change the high the low temperature alarm set point press zero To return to the temperature alarm set point menu press one Otherwise to return to the main menu press two If a 6 is pressed The position of the rem...

Page 4: ...he security code is factory set at 9999 Follow verbal prompts to change the security code Security code is also the location ID code BATTERY STATUS The low battery status alarm will occur at 7 volts Important Replace battery annually or when battery voltage drops below 7 volts The battery voltage will be checked every 10 minutes POWER STATUS The FreezeAlarm will report that the power is off in the...

Page 5: ... hang up after three rings preventing the answering machine from picking up the alarm call Caution Because of normal connection delays in long distance calls unit may hang up before three rings are heard at call to location Test thoroughly If dip switch 3 is in the DOWN position the FreezeAlarm will hang up after ten rings Depending on the length of your greeting the answering machine may record a...

Page 6: ... Temperature reading 40 F Check sensor connection to correct jack Please use the following example when ordering Other models are available FA I FreezeAlarm and FA D FreezeAlarm Custom Design Modifications In addition to standard models Control Products specializes in complete custom design of electronic controls Modifications of our standard controls are also available Please consult factory for ...

Page 7: ...terminate and be of no further effect at the time the Product is 1 damaged by extraneous causes such as fire water lightning etc or not maintained as reasonable and necessary 2 modified 3 improperly installed 4 repaired by someone other than the Warrantor 5 used in a manner or purpose for which the Product was not intended WARRANTORS OBLIGATION UNDER THIS WARRANTY IS LIMITED TO REPAIR OR REPLACEME...

Page 8: ...fied as soon as possible You will be informed of your right to file a complaint with the FCC Your telephone company may make changes in its facilities equipment operations or procedures that could affect the proper functioning of your equipment If they do you will be notified in advance to give you an opportunity to maintain uninterrupted telephone service If you experience trouble with this telep...

Reviews: