background image

Control4

®

 KNX 

 

 
 

Protection class 

II 

EN 61 140 

Isolation category 

Overvoltage category 

Pollution degree 

III under EN 60 664-1 

2 under EN 60 664-1 

Temperature range 

Operation 

Storage 

Transport

 

-

5 °C…+45 °C 

-

25…+55 °C 

-

25…+70 °C 

Ambient conditions 

Maximum air humidity 

93 %, no condensation allowed 

Design 

Modular installation device (MDRC) 

Modular installation device, Pro 

M

 

 

Main dimensions (H x W x D) 

90 x 72 x 64.5 mm 

 

Mounting width 

4 x 18 mm modules 

 

Mounting depth 

64.5 mm 

Mounting 

On 35 mm mounting rail 

EN 60 715 

Mounting position 

As required 

 

Weight 

Approx. 0.26 kg 

 

Housing, color 

Plastic housing, gray 

 

Approvals 

KNX under EN 50 090-1, -2 

 

CE mark 

In accordance with the EMC guideline and low 
voltage guideline 

 

 
 

Important 

If the device overheats due to extended overload (> 100 °C in housing) it switches off automatically. 
The LED is off. The device can be switched on again only after it has been disconnected from the mains 
for 60 seconds and has cooled to operational temperature internally. 
Eliminate the cause of the overload before switching back on. 

When commissioning the device, ensure that the rated current is not continuously exceeded. 

The voltage output without choke ( I

2

) is not electrically isolated from the KNX voltage output (I

1

). It may 

only be used to power an additional bus line in combination with a separate choke. It may not, 
for example, be used to power IP devices (see SELV guidelines). 

Devices are designed for continuous operation. They are not approved for frequent switching on and off. 

 

 

 

Summary of Contents for C4-KNX-PS640MA

Page 1: ......

Page 2: ...tional overview 6 1 2 1 Brief overview 6 2 2 1 Standard Power Supply 640 320 160 mA MDRC 7 2 1 1 Technical data 7 2 1 2 Connection schematic 9 2 1 3 Dimension drawing 10 2 1 4 Operating and display el...

Page 3: ...41 download https ctrl4 co knx ps640ma Subject to change Exclusion of liability Although the contents of this document have been checked to ensure that they are consistent with the hardware and softwa...

Page 4: ...pplication Section A Appendix All parameters are initially described in chapter 3 Following the parameter descriptions are descriptions for the communication objects Notes and safety instructions are...

Page 5: ...100 240 KNX rated voltage in V DC 30 KNX rated current in mA 640 Type of installation MDRC Mounting width in space units 4 Integrated choke Short circuit and overload monitoring Mains failure back up...

Page 6: ...uts KNX voltage output I1 Rated voltage UN Minimum distance between 2 power supplies in one line 1 line with integrated choke 30 V DC 1 2 V SELV 200 m KNX bus line Voltage output I2 Rated voltage UN w...

Page 7: ...ce with the EMC guideline and low voltage guideline Important If the device overheats due to extended overload 100 C in housing it switches off automatically The LED is off The device can be switched...

Page 8: ...Control4 KNX 1 Bus connection terminal 2 Label carrier 3 Power supply connection Us 4 Status LED 5 Voltage output without choke I2 2CDC072007F0013...

Page 9: ...Control4 KNX 2CDC072013F0013...

Page 10: ...specialists The appropriate standards directives regulations and specifications should be observed when planning and setting up electrical installations Protect the device from moisture dirt and dama...

Page 11: ...roduct to the project using the current application program After you have parameterized a device you can transfer the settings to a second device For this purpose the devices must already be availabl...

Page 12: ...nection schematic below Please note The voltage output without choke may not be used for other purposes e g for connecting sensors to a binary input because in the event of an error on the voltage out...

Page 13: ...D lights up for the duration of the reset The LED goes off when the reset is complete A reset takes around 20 seconds If the line is to be disconnected from the voltage for an extended period pull off...

Page 14: ...til there is no longer an overload and only the green UN OK LED is lit Flashing red Current limiting active Reduce number of bus devices until only the green UN OK LED is lit Communication error indic...

Page 15: ...A Appendix A 1 Ordering details Short description Description Weight 1 pcs kg Pkg qty pcs C4 KNX PS640MA KNXPROD File Name SV S 30 640 3 41 Download https ctrl4 co knx ps640ma KNX Power Supply 640 mA...

Page 16: ...Control4 KNX Notes...

Page 17: ...Control4 KNX...

Reviews: