CTT8 

instruction manual 

IM302-U v2.3 

pag. 2 / 8

 

WIRING CONNECTION 

Input  thermometric probes Pt 100

Se

ri

a

l

output

Rs

4

8

5

(opti

o

n)

R

elay

 o

u

tputs

*

Auxiliary power supply
U aux:
25 - 27:   24 ÷ 230V ca/cc
or
25 - 26: 115 Vca
25 - 27: 230 Vca
25 - 28: 400 Vca

white

red

red

Pt 100

view rear panel
of the instrument with terminals
for the connections

A

nalog

output

0-

20m

A

(4

-20m

A

)

(opti

o

n)

7

5

8

6

9

1

4

10

2

11

3

12

25

28

26 27

44 45 41 42 43

29 30 31 32 33 34 35 36 37 38 39 40

19

17

20

18

21

13

16

22

14

23

15

24

Input  thermometric probes Pt 100

Ch2

Ch3

Ch4

7

5

8

6

9

1

Ch1

4

10

2

11

3

12

38

39

40

41

42

43

44

45

25

26

27

28

B

A

gnd

U

 aux

.

CTT8

*

+
-

Ch7

Ch6

Ch5

14

17

Ch8

13

16

18

15

19

20

21

22

23

24

TR
IP

ALAR

M

29

30

31

32

33

34

35

36

37

 

Summary of Contents for CTT8

Page 1: ...efore to install and use the device The device described in this manual must be installed and used by personal opportunely learned Security Before to proceed at the installation it s necessary verify...

Page 2: ...view rear panel of the instrument with terminals for the connections Analog output 0 20mA 4 20mA option 7 5 8 6 9 1 4 10 2 11 3 12 25 28 26 27 44 45 41 42 43 29 30 31 32 33 34 35 36 37 38 39 40 19 17...

Page 3: ...nels 5 LED FAULT of indication failure device or thermometric probes 6 LED HOLD of indication function of manual reset activated 7 LED FAN of indication activation output of ventilation 8 push button...

Page 4: ...e value of temperature indicated on display Interval of programming from 25 C up to the threshold of enable ventilation 1 C Confirm with ENTER Selection threshold of enable ventilation The fan led on...

Page 5: ...e overcoming of 1 C of the value of threshold set on the input after 5 seconds on the channel where the threshold value has been exceeded the ALARM relay is energized and the ALARM led is on The resto...

Page 6: ...MAXIMUM MEASURED VALUE OF TEMPERATURE Pressing the Tmax key on displays appear in modality flashing the maximum measured value of temperature To pass from the visualization of the maximum temperature...

Page 7: ...with led 7 segments 3 digit Outputs 4 relay NO C NC 5 A resistive load Output functions alarm trip fan auto diagnostic fault Functions programmable ALARM TRIP HOLD FAN T MAX HOT Connection Extractibl...