CONTRACOR
®
Version 2.0
8
2. Cleaning and disinfecting.
After each session clean the abrasive blasting helmet, using a mixture of water and a
mild detergent. Subsequently, rinse thoroughly with clean water. (Do not use any solvents).
The face collar or neck bib can be washed in the washing machine, using a soft detergent
at 30°C. Using a disinfectant, clean the inner surfaces of the abrasive blasting helmet.
Refer to the instructions given by the manufacturer.
For reasons of hygiene, the same person should preferably wear the abrasive blasting
helmet. Using compressed air, blow clean the coupling and the regulator. Finally, using a
dry cloth, dry all the metal components, to avoid corrosion. When cleaning, take care not to
inhale hazardous matter that is released during the cleaning.
3. Maintenance and inspection
abrasive blasting helmet.
Positioning the disposable windows:
After opening the window frame fit a
disposable window (fig. 3).
Fig. 3. Exchanging disposable window.
Exchanging the neck seal:
The neck
seal can easily be exchanged by releasing of
zipping.
Exchanging the cape:
To exchange
the cape remove it from the rubber ring.
Exchanging the polyester visor:
Open the
window frame and remove the grid and the
disposable windows. The polyester visor can
now be extracted out of the rubber surround.
Take an original spare polyester visor and
slide this into the surround.