4. Using a screwdriver with a 2.5mm or 3mm blade, make all power, pump, 2-port zone
valve, boiler, programmer, thermostat and zone actuator terminal connections,
depending on the heating configuration, boiler type and control (see the following
wiring diagrams)
5.
Replace the HeatMax™ UFH wiring centre cover and replace all of the cover screws
Suggested cabling
Wiring schematics
Wiring schematics
Item
Cable
Fused spur / programmer to wiring centre
2-core + earth
UFH system pump wired to wiring centre
2-core + earth (fitted)
Programmable room thermostat to wiring
centre or wiring centre extension
2-core
Standard room thermostat to wiring centre
or wiring centre extension
4-core
Wiring schematic 230V switching to boiler