The RBT240 and RBT270 are braking test benches for
light vehicles.
3.1
Presentation of the different
elements
The electric control box communicates with the
braking test bench and sends the information to the
control trolley PC.
3.1.1
Control Trolley
›
The mobile cabinet
houses,
›
A large 23" coloured
screen with directional
mount for clear
visibility.
›
Windows 10 PC
›
Mouse & keyboard
with protective cover
›
A4 printer
The image can be
echoed to a remote
screen via the HDMI
port.
Optional:
›
Vehicle Exhaust Gas Analyser (VEGA)
›
Diesel Smoke Meter (DSM)
3.1.2
Electric Control Box
This unit houses:
›
the processing
card
›
The connection
terminals for the
sensors and
actuators
›
the control part
(contactors)
There is a location
for an emergency
stop.
3.1.3
RBT240 and MK240: Braking Bench
RBT240 Class 4 ATL
MK240 Motorcycle Adapter
3
Overview
Width of the braking area
800mm - 2,200mm
Height
275mm
Max. force
750 daN
Operating Manual RBT240 / RBT270
Operating Manual RBT240 / RBT270
14
15
2.14
Warranty terms and conditions
The warranty is voided by any alteration of the equipment
or use other than that defined by the manufacturer and
made without the manufacturer's permission, and by any
deterioration of specifications resulting from incorrect
servicing or the absence of precautions.
Any use of hardware and/or software not been approved by
Continental constitutes a modification of our products, and
hence exclusion of all liability and warranty claims, even if
the hardware has been subsequently removed, or the
software erased in the interim. Our products must not be
modified in any way. Furthermore, our products may only
be used with original accessories. Disregard for the above
will render all warranty claims invalid.
The present Continental tester may only be used with
operating systems approved by Continental. Using the
Continental tester with different operating systems to those
which we have approved will render our warranty obligation
null and void, in accordance with our terms of delivery. In
addition, we cannot assume liability for damages and
consequential damages which are the result of the use of a
non-approved operating system.
Full terms and conditions are available on request.
Continental cannot be held liable for incorrect
measurements resulting from the use of an operating mode
different from the one recommended in this manual, or if
the operating, servicing and safety conditions are not
followed.
2.15
Working environment conditions
The equipment environment must meet the following
specifications:
The equipment must be used under shelter.
Temperature:
field of reference
20ºC 5.
Surrounding
temperature
(max. Range)
B0ºC and +40ºC
Operating
conditions
Relatively humidity between 5% and 85%
Water
Negligible (no vertical dripping of drops of water).
No traces of damp on the wall of the premises
and correct ventilation
Dust
The dust must not have any electrical impact
Presence of solid bodies greater than 2.5mm
Corrosive
substances
Possible presence of corrosive or polluting agents
from atmospheric pollution, but no direct contact
Impacts
Impacts less than 2 joules
Vibrations
Usual in an industrial environment. Frequency
between 10 and 50Hz. Amplitude less than
0.15mm
Electromagnetic
and electronic
influences or
radiation
No power switchgear, high frequency current
emitters, devices containing radioactive
substances, high voltage power lines, electricity
transport lines close by.
Sunlight
It should be reduced to a minimum
Grounding
Grounding must be carried out according to the
type of soil and in compliance with applicable
regulations.