background image

24

20.83

FREEZERS

VLFLT305

SPECIFICATIONS

A Division of National Refrigeration & A/C Products, Inc.
539 Dunksferry Road Bensalem, PA 19020
(800) 523-7138 Fax: (215) 244-9579
www.continentalrefrigerator.com

1F-LT

2F-LT

3F-LT

One Section

Two Section

Three Section

CHARACTERISTICS

Reach-In

Reach-In

Reach-In

DIMENSIONAL DATA

Net Capacity (cu. ft.)

20

48

70

Width, Overall (in.)

26

52

78

Depth, Overall (Incl. Hdls.) (in.)

35

1

/

2

35

1

/

2

35

1

/

2

Depth (Less Door(s)) (in.)

32

32

32

Depth (Doors(s) Open 90°) (in.)

55

1

/

2

55

1

/

2

55

1

/

2

Clear Door Width (in.)

19

3

/

8

19

3

/

8

19

3

/

8

Clear Full-Door Height (in.)

58

5

/

8

58

5

/

8

58

5

/

8

Clear Half-Door Height (in.)

27

1

/

2

27

1

/

2

27

1

/

2

Height, Overall (Inc. 5" Casters)(in.)

85

3

/

4

85

3

/

4

85

3

/

4

No. of Full Door(s)

1

2

3

No. of Half Door(s)

2

4

6

No. of Shelves

3

6

9

Shelf Area (sq. ft.)

20.4

40.8

61.2

Tray Slide Capacity (Half)

11 ea.

11 ea.

11 ea.

Tray Slide Capacity (Full)

24 ea.

24 ea.

24 ea.

REFRIGERATION DATA

Condensing Unit Size (H.P.)

3

/

4

1

2

Capacity (BTU/Hr)*

2050

3175

6300

ELECTRICAL DATA

Cabinet Specifications

115/208-230/60/1 115/208-230/60/1 115/208-230/60/1

Feed Wires (Incl. Ground)

4

4

4

Condensing Unit Specs.

208-230/60/1

208-230/60/1

208-230/60/1

Total Amperes

10.8

13.1

20.0

Cabinet Amperes

1.6

2.7

3.6

Defrost Amperes

5.2

9.6

10.4

Power Supply Cord

no

no

no

SHIPPING DATA

Height – crated (in.)

85

1

/

2

85

1

/

2

85

1

/

2

Width – crated (in.)

31

5

/

8

64

90

Depth – crated (in.)

42

42

42

Volume – crated (in.)

65

133

187

Weight Std – crated (lbs.)

450

565

810

Weight SS – crated (lbs.)

510

645

925

Weight Std – uncrated (lbs.)

350

395

600

Weight SS – uncrated (lbs.)

410

475

715

* Rating @ -30°F Evaporator, 90° Ambient
Note: All specifications subject to change without notice.

Note: If the cabinet is located directly against wall and/or under low ceiling,
a minimum clearance of 2" is required.

5" CASTERS

52"

85

3

/

4

"

85

3

/

4

"

5" CASTERS

26"

32"

35

1

/

2

"

85

3

/

4

"

5" CASTERS

78"

Reviews: