![Continental Instruments CICP1800 Datasheet Download Page 2](http://html1.mh-extra.com/html/continental-instruments/cicp1800/cicp1800_datasheet_2657206002.webp)
A standard on-board power supply provides 800mA @5VDC
or 500mA @12VDC for reader power. An additional
3A@12VDC is available with the optional expanded power
supply. The Superterm can be ordered with a factory installed
expanded power supply. The expanded power supply can also
be ordered separately and field installed within the Superterm
enclosure. The expanded power supply includes a 12AH
standby battery, an upgrade to the standard 7AH battery. The
standard 7AH and expanded 12AH batteries provide 4–6 hours
standby. In addition to the rechargeable standby battery, each
Superterm includes a lithium battery for up to one year of data
protection.
The Superterm-8 is UL Listed for UL294 (Access Control
System Unit), UL1076 (Proprietary Burglar Alarm Unit) and
UL1950** (Information Technology Equipment).
Typical Door Configuration
See Continental Instruments Configuration Guide for
additional detailed system wiring information.
Continental Instruments, A Napco Security Group Company
•
355 Bayview Ave., Amityville, NY 11701
(631) 842-9400
•
FAX (631) 842-9135 www.cicaccess.com GSA GS-07F-00039H
CardAccess® and CI SQL 3000™ are trademarks of Continental/NAPCO. © Continental Instruments/NAPCO, 2003.
CICP1800 Eight-Door Intelligent Controller
Continental Instrument’s Controllers can connect to the
CardAccess Server via hardwire (shown below), LAN/WAN
dial-up modem or fiber optics. See the CIC Configuration
Guide for additional detailed system information.
Superterm-8 Components
QTY.
Part No.
Description
1
CICP1800
or
CICP1800EXP
Eight (8) reader controller with stan-
dard 20,000 card capacity, 24
supervised alarm inputs, tamper
alarm, and 17 relay outputs. Unit ships
complete in a locked steel enclosure
including a 7AH standby battery for
memory and system operation.
Same as above, with expanded power
supply. Required if more than one Re-
lay Expander Board (CICP1800RB) is
used or additional 12VDC is needed. A
12AH Battery is included.
1
Standard
14VAC Power Supply via step-
down transformer mounted inside
enclosure. 10’ power line cable with
110VAC plug is included.
1
Standard
7AH Battery Backup included.
1 Optional CICEXPPWS
12V Linear Expanded Power
Supply provides 3A @ 12VDC
Auxiliary Power. 12AH Battery is
included.
1 Optional CICP1800MB2-1
Memory Board - 2MB (up to 145,000
cardholders).
Up to 3
Optional*
CICP1800RB
Relay Expander Board - 16 output
relays, 8 alarm inputs (Unsupervised).
Up to 3
Optional*
CICP1800AB
Alarm Expander Board - 16 alarm
inputs (Supervised). UL Listed.
Note: *A maximum of 3 Expansion Boards in any combination may be added to the Superterm
enclosure.
Door Contact
Electric
Door Strike
Door Lock
Power Supply
RS422 to Panels
Continental
Instruments llc
Request to Exit
Motion Detector
Door Contact
Card Reader
Request
to Exit
Bu
Door Lock
A or B
G
D
G
G
G
Request
to Exit
G
H
G
NOTE:
Request to Exit motion detectors will require
an additional 12VDC power cable. Exit devices are
typically mounted on the egress side of door.
CardAccess 3000
Database and
Communications
Server
CICE1940PL-1
Polling Line Converter
RS232 to RS422
Required if server is not located
within 50
RS422 Repeat Mode Communications Network
4000' max. distance between controllers.
Up to 63 controllers on a Repeat Mode Network.
perterm
Sup
p
perterm
Sup
p
RS422
x. 4000'
RS422
Max. 4000'
RS422
Max. 4000'
RS422
Max. 4000'
RS422
Max. 4000'