Continental Hydraulics J Design Series Service Manual Download Page 3

3

Form No. R32.00    Rev. 4/99

A pressure gauge located at the pump must be used
when making adjustment to insure the pressure
settings do not exceed limits specified for the particular
pump of maximum system pressure.

Make all pressure settings with pump operating against
a closed circuit, that is with the output of the pump
blocked, and then check pressure throughout the pump
flow range.

Volume Control

Adjust volume at minimum pump pressure or at pump
deadhead.  The volume adjusting screw is directly
opposite the pressure adjusting screw, see parts page
item number 55.  The adjusting screw has a right hand
thread, turning the screw clockwise decreases the
maximum volume, turning the screw counterclockwise
increases the maximum volume.  Pumps are set at a
maximum rated volume at the factory unless otherwise
specified.

Stop adjustment of the volume screw when pressure
begins to drop.  See Sales Catalog for complete pump
performance specifications.

ADJUSTMENT PROCEDURES

To adjust the maximum output volume use the follow-
ing steps:

1.  Set the pump at minimum pressure.

2.  Hand tighten the volume screw until it touches cam

ring. NOTE: The pump should be at full flow for this
step.

PRESSURE & VOLUME ADJUSTMENT SENSITIVITY

Pressure
Adjustment

PUMP SIZE   15B   20B   30B

Pressure
Change/Turn

PSI

(bar)

230

(16)

310

(21)

230

(16)

Maximum
Torque

Ft-lbs.

(m-kg)

15

(2)

20

(3)

15

(2)

Volume
Adjustment

Flow  Change
Turn

gpm

(lpm)

10

(38)

10

(38)

13

(49)

Approx. Min.
Flow Adj.

gpm

(lpm)

2

(7.5)

2

(7.5)

3.5

(13)

Maximum
Torque

Ft-lbs.

(m-kg)

21

(3)

29

(4)

21

(3)

CAUTION

 - Turning the maximum volume

control in too far can force the cam ring over-
center and destroy the pump.

3.  See Pressure and Volume Adjustment Sensitivity

chart below.

4.  Deadhead the pump, turn the volume screw the

proper number of turns to obtain the flow desired.

5.  Return pump to flow condition and check flow rate.

If output flow is incorrect, switch pump to deadhead
and readjust per above.

PVR15 KIT LIST

WEAR PLATE KITS

MODEL

KIT NUMBER

15B

252620

20B

252621

VANE KITS

Includes Item:  7.

MODEL

KIT NUMBER

All Models

250310

SEAL KITS

Includes Item:  13,14,15,16,17,24,25,27,28,29,34,37,39.

MODEL

KIT NUMBER

All Buna N

250008

All Viton

250009

COMPLETE REBUILD KITS

MODEL

KIT NUMBER

15B

252777

20B

252778

ROTATING KITS

Includes Items:  3,6, and 21.

MODEL

KIT NUMBER

15B

127894

20B

130690

Summary of Contents for J Design Series

Page 1: ...the coupling for the two shafts to ride independently To prevent end loading the space between the pump and motor shaft ends should be inch for PVR15 pumps or as the coupling manufacturer specifies P...

Page 2: ...ef valve in parallel with the heat exchanger No other return lines should be con nected in common with the case drain return 5 Rotate pump and motor by hand to insure free rotation 6 Set the machine c...

Page 3: ...mp at minimum pressure 2 Hand tighten the volume screw until it touches cam ring NOTE The pump should be at full flow for this step PRESSURE VOLUME ADJUSTMENT SENSITIVITY Pressure Adjustment PUMP SIZE...

Page 4: ...Viton 113215 O Ring 1 17 102556 O Ring 1 17 Viton 117505 O Ring 1 18 198307 Soc Hd Cap Screw 4 19 165219 Thrust Screw 1 PVR15 PARTS LIST ITEM CODE PART DESCRIPTION NO NO NO REQ 20 250368 Thrust Screw...

Page 5: ...5 Form No R32 00 Rev 4 99 PVR15 PARTS DRAWING...

Page 6: ...Form No R32 00 Rev 4 99 PVR15 PARTS DRAWING CODES 8 15 17 36 CODE 15 Handwheel Pressure Control CODE 17 Dual Pressure Controller CODE 8 Rate Control for Dual Pressure CODE 36 Handwheel Volume Control...

Page 7: ...s should not be reused once they have been removed 11 It is unlikely that further disassembly will be neces sary in order to perform routine maintenance on the pump REASSEMBLY PROCEDURE 1 Clean and in...

Page 8: ...ue the cover bolts to 100 lbs ft The shaft should turn by hand when assembly is complete 12 Lubricate the ID of the two shaft seals 24 and press them into the housing to the depth shown below Note the...

Reviews: