background image

25

W415-0298 / N / 02.29.12

CONTINENTAL® warrants its products against manufacturing defects to the original purchaser only. Registering your warranty is not necessary. 
Simply provide your proof of purchase along with the model and serial number to make a warranty claim. CONTINENTAL® reserves the right to 
have its representative inspect any product or part thereof prior to honouring any warranty claim. Provided that the purchase was made through an 
authorized CONTINENTAL® dealer your appliance is subject to the following conditions and limitations:
Warranty coverage begins on the date of original installation. 
This factory warranty is non-transferable and may not be extended whatsoever by any of our representatives.
The gas appliance must be installed by a licensed, authorized service technician or contractor. Installation must be done in accordance with the 
installation instructions included with the product and all local and national building and fi re codes.   This limited warranty does not cover damages 
caused by misuse, lack of maintenance, accident, alterations, abuse or neglect and parts installed from other manufacturers will nullify this warranty.
This limited warranty further does not cover any scratches, dents, corrosion or discoloring caused by excessive heat, abrasive and chemical cleaners 
nor chipping on porcelain enamel parts, mechanical breakage of PHAZER™ logs and embers.
CONTINENTAL® warrants its stainless steel burners against defects in workmanship and material for life, subject to the following conditions: During 
the fi rst 10 years CONTINENTAL® will replace or repair the defective parts at our option free of charge. From 10 years to life, CONTINENTAL® will 
provide replacement burners at 50% of the current retail price.
In the fi rst year only, this warranty extends to the repair or replacement of warranted parts which are defective in material or workmanship provided 
that the product has been operated in accordance with the operation instructions and under normal conditions.
After the fi rst year, with respect to this President’s Lifetime Limited Warranty, CONTINENTAL® may, at its discretion, fully discharge all obligations 
with respect to this warranty by refunding to the original warranted purchaser the wholesale price of any warranted but defective part(s).
CONTINENTAL® will not be responsible for installation, labour or any other expenses related to the reinstallation of a warranted part and such 
expenses are not covered by this warranty.
Notwithstanding any provisions contained in the President’s Lifetime Limited Warranty, CONTINENTAL’S responsibility under this warranty is defi ned 
as above and it shall not in any event extend to any incidental, consequential or indirect damages.
This warranty defi nes the obligations and liability of CONTINENTAL® with respect to the CONTINENTAL® gas appliance and any other warranties 
expressed or implied with respect to this product, its components or accessories are excluded.
CONTINENTAL® neither assumes, nor authorizes any third party to assume, on its behalf, any other liabilities with respect to the sale of this product. 
CONTINENTAL® will not be responsible for: over-fi ring, downdrafts, spillage caused by environmental conditions such as rooftops, buildings, nearby 
trees, hills, mountains, inadequate vents or ventilation, excessive venting confi gurations, insuffi cient makeup air, or negative air pressures which may 
or may not be caused by mechanical systems such as exhaust fans, furnaces, clothes dryers, etc.
Any damages to appliance, combustion chamber, heat exchanger, brass trim or other components due to water, weather damage, long periods of 
dampness, condensation, damaging chemicals or cleaners will not be the responsibility of CONTINENTAL®.
All parts replaced under the President’s Limited Lifetime Warranty Policy are subject to a single claim.
During the fi rst 10 years CONTINENTAL® will replace or repair the defective parts covered by the lifetime warranty at our discretion free of charge.  
From 10 years to life, CONTINENTAL® will provide replacement parts at 50% of the current retail price.
All parts replaced under the warranty will be covered for a period of 90 days from the date of their installation.
The manufacturer may require that defective parts or products be returned or that digital pictures be provided to support the claim.  Returned products 
are to be shipped prepaid to the manufacturer for investigation.  If a product is found to be defective, the manufacturer will repair or replace such 
defect.
Before shipping your appliance or defective components, your dealer must obtain an authorization number.  Any merchandise shipped without 
authorization will be refused and returned to sender.
Shipping costs are not covered under this warranty.
Additional service fees may apply if you are seeking warranty service from a dealer.
Labour, travel, diagnostic tests, shipping and other related charges are not covered by this warranty.

2.8B

CONTINENTAL® products are manufactured under the strict Standard of the world recognized ISO 9001 : 2008 Quality 

Assurance Certifi cate.

CONTINENTAL® products are designed with superior components and materials assembled by trained craftsmen 

who take great pride in their work. The burner and valve assembly are leak and test-fi red at a quality test station. The 

complete appliance is again thoroughly inspected by a qualifi ed technician before packaging to ensure that you, the 

customer, receives the quality product that you expect from CONTINENTAL®.

The following materials and workmanship in your new CONTINENTAL® gas appliance are warranted against defects 
for as long as you own the appliance. This covers: combustion chamber, heat exchanger, stainless steel burner, 
phazer™ logs and embers, rocks, ceramic glass (thermal breakage only), gold plated parts against tarnishing, 
porcelainized enameled components and aluminum extrusion trims.*
Electrical (110V and millivolt) components and wearable parts such as blowers, gas valves, thermal switch, switches, 
wiring, remote controls, ignitor, gasketing, and pilot assembly are covered and CONTINENTAL® will provide 
replacement parts free of charge during the fi rst year of the limited warranty.*
Any labour related to warranty repair is not covered.
* Construction of models vary. Warranty applies only to components included with your specifi c appliance.

CONTINENTAL® GAS APPLIANCE PRESIDENT’S LIFETIME LIMITED WARRANTY

CONDITIONS AND LIMITATIONS

ALL SPECIFICATIONS AND DESIGNS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUT TO ON-GOING PRODUCT IMPROVEMENTS. 

CONTINENTAL® IS A REGISTERED TRADEMARK OF WOLF STEEL LTD.

12.0 WARRANTY

Summary of Contents for CVF36N

Page 1: ...ely call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by...

Page 2: ...ETERMINING CONFINED OR UNCONFINED SPACE 7 3 3 GAS INSTALLATION 8 3 4 OPTIONAL WALL SWITCH THERMOSTAT 9 3 5 MOBILE HOME INSTALLATION 9 4 0 FRAMING 10 4 1 MINIMUM CLEARANCE TO COMBUSTIBLES 11 4 2 MINIMU...

Page 3: ...d hearth guards to protect children from hot surfaces These screens and guards must be fastened to the floor Any safety screen or guard removed for servicing must be replaced prior to operating the ap...

Page 4: ...install the appliance to the current National Fuel Gas Code ANSI Z223 1 Installation Code which can be obtained from American National Standards Institute Inc or National Fire Protection Association I...

Page 5: ...the fuel Incomplete combustion results in soot being deposited inside the firebox as well as surfaces outside the appliance If any soot deposits are observed shut off the appliance immediately and ar...

Page 6: ...CATALYTIC DOOR MAXIMUM HORIZONTAL EXTENSION 2 SEE INSTRUCTION MANUAL FOR GREATER EXTENSIONS ELECTRICAL RATING 115V 0 82AMP 60HZ OPTIONAL FAN KIT GZ550 KT 9700539 WSL 4001657 NGZ 4001658 NAC 4001659 W...

Page 7: ...pproximately one ounce of water for every 1 000 BTU hr of gas input During the cold weather season indoor humidity levels tend to be low Consequently this water vapour can enhance the living space How...

Page 8: ...manual shut off valve to turn off the gas supply to the appliance C Connect the gas supply in accordance to local codes In the absence of local codes install to the current CAN CSA B149 1 Installatio...

Page 9: ...FF switch and replace with the leads from the wall switch millivolt thermostat 50 1 3 1 2 WARNING DO NOT CONNECT EITHER THE WALL SWITCH THERMOSTAT OR GAS VALVE DIRECTLY TO 110 VOLT ELECTRICITY 29 2 Su...

Page 10: ...TING ENTIRELY OF STEEL IRON BRICK TILE CONCRETE SLATE GLASS OR PLASTERS OR ANY COMBINATION THEREOF ARE SUITABLE MATERIALS THAT ARE REPORTED AS PASSING ASTM E 136 STANDARD TEST METHOD FOR BEHAVIOUR OF...

Page 11: ...may occur at or after a minimum distance of 2 away from the side of the appliance Thereafter the depth of any protrusions must be of equal to or less than the distance from the side of the appliance u...

Page 12: ...sure space around and above the appliance must be left unobstructed 4 3 MINIMUM MANTEL CLEARANCES WARNING RISK OF FIRE MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES FAILURE TO COMPLY WIT...

Page 13: ...re just removed E Install the one piece log set by aligning the two holes on the bottom of the logs with the two locating pins in the firebox Reinstall rod assembly and mesh curtain NOTE PHAZERTM logs...

Page 14: ...e embers into pieces and place along the front row of ports covering all of the burner area in front of the small logs Care should be taken to shred the embers into thin small irregular pieces as only...

Page 15: ...ERSAL HARNESS WHEN INSTALLED ENSURE THAT ANY EXCESS WIRE IS CONTAINED PREVENTING IT FROM MAKING CONTACT WITH MOVING OR HOT OBJECTS 51 5 Remove the backing of the logo supplied and place on the screen...

Page 16: ...e blower does not touch the appliance base or the firebox Attach the connectors from the black and white wires to the thermal switch and secure the thermal switch bracket to the bottom left of the uni...

Page 17: ...ront of the back log G Turn gas knob counter clockwise to pilot H Depress and hold gas knob while lighting the pilot with the push button ignitor Keep knob fully depressed for one minute then release...

Page 18: ...y allow 15 to 30 minutes for the final flame colour to be established AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIED INSTALLER AIR SHUTTER OPENING VENTURI BURNER ORIFICE 49 1 AIR SHUTTER OPEN...

Page 19: ...CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing This appliance and its venting...

Page 20: ...DEPLETION SENSOR SYSTEM LP 3 W680 0004 THERMOPILE 4 W725 0030 NATURAL GAS VALVE 4 W725 0031 PROPANE GAS VALVE 5 W385 0430 CONTINENTAL LOGO 6 W750 0112 20FT OF WIRE 7 GL 664 ONE PIECE LOG SET W135 033...

Page 21: ...ECTIVE RADIANT PANELS 36 TB336K BEVELLED TRIM KIT 3 COVERS OPENING 37 W X 33 H TEXTURED BLACK 36 TB336AB BEVELLED TRIM KIT 3 COVERS OPENING 37 W X 33 H ANTIQUE BRASS 36 TB336PB BEVELLED TRIM KIT 3 COV...

Page 22: ...ow Service or replace Oxygen Depletion Sensor System Correct piping and or regulator to provide correct pressure Ensure adequate supply pressure Pilot goes out when the gas knob is released The gas va...

Page 23: ...and see if pilot flame flutters diminishes or extinguishes especially when main burner ignites Monitor appliance supply working pressure Check if supply piping size is to code Correct all undersized...

Page 24: ...of the methods described in ANSI Z223 1 NFPA 54 or the applicable local code Not enough ventilation air Increase fresh air supply Use one of the methods described in ANSI Z223 1 NFPA 54 or the applica...

Page 25: ...ironmental conditions such as rooftops buildings nearby trees hills mountains inadequate vents or ventilation excessive venting configurations insufficient makeup air or negative air pressures which m...

Page 26: ...26 W415 0298 N 02 29 12 13 0 SERVICE HISTORY 43 1...

Page 27: ...27 W415 0298 N 02 29 12 44 1 14 0 NOTES...

Page 28: ...28 W415 0298 N 02 29 12 44 1...