background image

20

W415-0858 / A / 02.14.11

This appliance comes equipped with our “Night Light™”. If in the event the lamp 
needs to be replaced, follow these instructions.

A. 

Turn off all electrical supply.

B.

 

Remove the glass media and media tray from the fi rebox, see "MEDIA 
TRAY INSTALLATION" section.

C.

 

Unscrew the lens cover. 

NOTE: Do not handle the lamp with bare 

fi ngers, protect with a clean dry cloth.

D.

 

The lamp will pull straight out of the socket. Replace with Wolf Steel 
Ltd. parts only (W387-0009), as lamp and lens are special "high temperature" products.

E.

 Replace 

lens.

F. 

Replace glass media and media tray.

10.1 LAMP REPLACEMENT

A. 

Remove the glass media and media tray, see "MEDIA TRAY 
INSTALLATION" section.

B.

 

Remove the 2 screws holding the lamp assembly shield.

C. 

Compress the 3 retainer fi ns and lift out the lamp assembly. Disconnect 
the wires.

D.

 

Replace lamp assembly by aligning key hole and snap into place. Re-
connect the wires.

E.

 

Re-install the lamp assembly shield.

F.

 

Re-install media tray and glass media.

NOTE: When removing the media tray make sure the glass media is away 
from the center of the screen, exposing the burner, before lifting media tray 
out. 

When replacing burner, absolutely no glass media can be in cup surrounding the 
orifi ce. 

HINT: If glass falls into cup and surrounds the orifi ce, insert a clean 

bag into a vacuum cleaner and vacuum out glass media. Replacement glass 
media can be ordered from Wolf Steel Ltd.

10.2  LAMP ASSEMBLY REPLACEMENT

THE FRONT OF THE APPLIANCE BECOMES VERY HOT DURING OPERATION. LET THE APPLIANCE 

COOL COMPLETELY BEFORE CONDUCTING SERVICE. 

!

WARNING

KEY HOLE

RETAINER 
FINS

LAMP ASSEMBLY 
SHIELD

Summary of Contents for CDI-30GN

Page 1: ...gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the supplier This appliance may be installed as an OEM installation in manu...

Page 2: ...Y INSTALLATION 13 5 4 MEDIA INSTALLATION 13 5 5 LOGO PLACEMENT 13 6 0 REPLACEMENT BLOWER INSTALLATION 14 7 0 OPERATION 15 7 1 OPERATING AND LIGHTING INSTRUCTIONS 15 7 2 ANTI CONDENSATION SWITCH 16 8 0...

Page 3: ...INSTALLATION CHIMNEY CONNECTION section Glass see FINISHING GLASS BURNER INSTALLATION section Surround see FINISHING 4 SIDED SURROUND INSTALLATION section Door see FINISHING DOOR REMOVAL AND INSTALLAT...

Page 4: ...ce is a vented gas fired appliance Do not burn wood or other materials in the appliance It is imperative that the control compartments burners and circulating blower and its passageway in the applianc...

Page 5: ...edroom or bathroom unless the unit is a direct vent sealed combustion product ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED P...

Page 6: ...blowers If an optional fan or blower is installed the junction box must be electrically connected and grounded in accordance with local codes use the current CSA C22 1 Canadian Electrical Code in Can...

Page 7: ...SONT 10 PIEDS ET 35 PIEDS RESPECTIVEMENT MINIMUM AND MAXIMUM VERTICAL VENT LENGTHS ARE 10 FEET AND 35 FEET RESPECTIVELY LES LONGUEURS VERTICALES MINIMALES ET MAXIMALES SONT 10 PIEDS ET 35 PIEDS RESPE...

Page 8: ...COMBUSTIBLE STRAPPING TO MAINTAIN THE REQUIRED CLEARANCE FROM COMBUSTIBLES USE WOLF STEEL LTD SUPPORT RING ASSEMBLY W010 0370 OR EQUIVALENT NON COMBUSTIBLE STRAPPING TO MAINTAIN THE MINIMUM CLEARANCE...

Page 9: ...p the one end of a liner a minimum of 2 over the sleeve of the air terminal Secure using 3 screws Then seal the joint and screw heads with high temperature sealant Repeat with the other liner NOTE We...

Page 10: ...odes install to the cur rent CAN CSA B149 1 Installation Code in Canada or to the current National Fuel Gas Code ANSI Z223 1 NFPA 54 in the United States D When flexing any gas line support the gas va...

Page 11: ...T MANTEL FRONT ETC ARE CLEARLY MAINTAINED WHEN USING PAINT OR LACQUER TO FINISH THE MANTEL THE PAINT OR LACQUER MUST BE HEAT RESISTANT TO PREVENT DISCOLOURATION 73 1 This insert must be recessed into...

Page 12: ...ck on off switch wires already connected to the frame to the white and green wires located on the lower right hand side of the appliance control compartment B Connect the black light switch wire alrea...

Page 13: ...ply push the media away from the burner ports NOTE The distribution of glass media over the burner tube will influence the flame height When the flames impinge on the glass the glass may discolour sli...

Page 14: ...y activated when turned on it will automatically start approximately 5 15 minutes after lighting the appliance insert and will run for approximately 30 45 minutes after the appliance insert has been t...

Page 15: ...URALA L ELECTRICITE CONSULTE LES INSTRUCTIONS D INSTALLATION A CET APPAREIL EST MUNI D UN DISPOSITIF D ALLUMAGE QUI ALLUME LA VEILLEUSE AUTOMATIQUEMENT N ESSAYE PAS D ALLUMER LA VEILLEUSE MANUELLEMENT...

Page 16: ...harness before using the appliance Place near the IPI board Batteries not included NOTE If battery backup is used it must be connected to a 6 volt battery pack 7 2 ANTI CONDENSATION SWITCH This appli...

Page 17: ...17 W415 0858 A 02 14 11 AC Adaptor To ON OFF switch located on the top right hand corner of manditory trim 8 1 NIGHT LIGHTTM WIRING DIAGRAM...

Page 18: ...orifice insert a clean bag into a vacuum cleaner and vacuum out glass media Replacement glass media can be ordered from Wolf Steel Ltd 9 0 ADJUSTMENTS 9 1 PILOT BURNER ADJUSTMENT 9 2 VENTURI ADJUSTME...

Page 19: ...opile as well as reaches the burner 5 Replace the cleaned logs rocks or glass Failure to properly position the media may cause carboning which can be distributed in the surrounding living area 6 Check...

Page 20: ...holding the lamp assembly shield C Compress the 3 retainer fins and lift out the lamp assembly Disconnect the wires D Replace lamp assembly by aligning key hole and snap into place Re connect the wire...

Page 21: ...Place the door frame face down careful not to scratch the paint B Center the gasketed glass inside the door frame with the thick side of the gasket facing up C Bend the glass retainers located along t...

Page 22: ...W725 0062 SIT VALVE NG 2 W725 0063 SIT VALVE LP 3 W456 0042 42 NATURAL GAS BURNER ORIFICE 3 W456 0054 54 PROPANE GAS BURNER ORIFICE 4 W010 1865 NATURAL GAS PILOT ASSEMBLY 4 W010 1866 PROPANE GAS PILO...

Page 23: ...IES REF NO PART NO DESCRIPTION 1 F40 ON OFF REMOTE 1 F50 THERMOSTAT REMOTE 2 GD 660 REMOTE WALL SWITCH WITH 20 WIRE 3 W660 0026 TIMER BATTERY OPERATED 4 GI RB RISER BOX PAINTED BLACK 5 W175 0322 CONVE...

Page 24: ...d into the module Check voltage of the transformer under load at the spade connections on the module with the ON OFF switch in the ON position Acceptable readings of a good transformer are between 6 2...

Page 25: ...me rectification Verify correct pilot orifice is installed and inlet gas specifications to manual Remember the flame carries the rectification current not the gas If the flame lifts from pilot hood th...

Page 26: ...ue lazy transparent flame Blockage in vent Remove blockage In really cold conditions ice buildup may occur on the terminal and should be removed To minimize this from happening again it is recommended...

Page 27: ...ftops buildings nearby trees hills mountains inadequate vents or ventilation excessive venting configurations insufficient makeup air or negative air pressures which may or may not be caused by mechan...

Page 28: ...28 W415 0858 A 02 14 11 14 0 SERVICE HISTORY 43 1...

Reviews: