49
W415-1679 / D / 03.09.18
EN
69.7A
!
WARNING
DO NOT WIRE 110 VOLTS TO THE VALVE OR WALL SWITCH
ON / OFF
SWITCH
ACS/IPI
SWITCH
BATTERY
HOUSING
(SUPPLIED IN
MANUAL BAGGIE)
GROUND
DFC
VALVE
ORANGE
GREEN
GROUND
EYELET
ON / OFF
IPI / CPI
DISCONNECT THESE
CONNECTIONS TO THE
ON/OFF SWITCH AND
CONNECT TO AN
OPTIONAL THERMOSTAT.
IPI BOARD
DC SUPPLY
TRANSFORMER
VALVE
ELECTRONIC
OFF ON
NOTE: The battery housing was supplied with the appliance. In an event of a power failure, install 4 'AA'
batteries (not supplied) in the housing and attach to wire harness as illustrated above.
Legend
DFC
Digital Fireplace Control
DC
Direct Current
IPI
Intermittent Pilot Ignition
CPI
Continuous Pilot Ignition
ACS
Anti-Condensation Switch
(OPTIONAL)
7.0 wiring diagram
7.1 wiring requirements for CB36 / CX36-1
7.2 CB36 electronic wiring diagram
This appliance must be electrically connected and grounded in accordance with local codes. In the absence of
local codes, use the current CSA C22.1 Canadian Electrical Code in Canada or the ANSI/NFPA 70-1996 National
Electrical Code in the United States.
It is necessary to hard wire this appliance.
Permanently framing the appliances with an enclosure requires the
appliances' junction boxes to be hard wired. This appliance must be electrically connected and grounded in
accordance with local codes. In the absence of local codes, use the current CSA C22.1 Canadian electrical code
in Canada or the ANSI/NFPA 70-1996 national electrical code in the United States.
BATTERY
HOUSING