Continental Fireplaces BCDV42N Installation And Operating Instructions Manual Download Page 43

43

W415-0778 / D / 09.13.12

12.0 TROUBLESHOOTING

SYMPTOM

PROBLEM

TEST SOLUTION

Main burner goes out; pilot 
stays on.

Pilot 

fl

 ame is not large 

enough or not engul

fi

 ng the 

thermopile.

 

-

Turn up the pilot 

fl

 ame.

 

-

Replace pilot assembly.

Thermopile shorting.

 

-

Clean thermopile connection to the valve. Reconnect.

 

-

Replace thermopile / valve.

Remote wall switch wire is too 
long; too much resistance in 
the system.

 

-

Shorten wire to correct length or wire gauge.

Faulty thermostat or switch.

 

-

Replace.

Main burner goes out; pilot 
goes out.

Refer to “MAIN BURNER GOES OUT; PILOT STAYS ON”
Vent is blocked

 

-

Check for vent blockage.

Vent is re-circulating

 

-

Check joint seals and installation

Flexible vent has become 
disconnected from appliance.

 

-

Re-attach to appliance.

 

-

Cap was not replaced.

Pilot goes out when the 
gas knob is released.

The gas valve has an 
interlock device which 
will not allow the pilot 
burner to be lit until 
the thermocouple 
has cooled. Allow 
approximately 60 
seconds for the 
thermocouple to cool.

System is not correctly purged

 

-

Purge the gas line.

Out of propane gas.

 

-

Fill the tank.

Pilot 

fl

 ame is not large 

enough.

 

-

Turn up the pilot 

fl

 ame.

Pilot 

fl

 ame is not engul

fi

 ng the 

thermocouple

 

-

Gently twist the pilot head to improve the 

fl

 ame pattern 

around the thermocouple.

Thermocouple shorting / faulty.

 

-

Loosen and tighten thermocouple.

 

-

Clean thermocouple and valve connection.

 

-

Replace thermocouple.

 

-

Replace valve.

Faulty valve.

 

-

Replace.

Pilot burning; no gas to 
main burner; gas knob 
is on ‘HI’; wall switch / 
thermostat is on.

Thermostat or switch is 
defective

 

-

Connect a jumper wire across the wall switch terminals; 
if main burner lights, replace switch / thermostat.

Wall switch wiring is defective.

 

-

Disconnect the switch wires & connect a jumper wire 
across terminals 1 & 3; if the main burner lights, check 
the wires for defects and/or replace wires.

Main burner ori

fi

 ce is plugged. 

 

-

Remove stoppage in ori

fi

 ce.

Faulty valve.

 

-

Replace.

Pilot goes out while 
standing; Main burner is in 
‘OFF’ position.

Gas piping is undersized.

 

-

Turn on all gas appliances and see if pilot 

fl

 ame 

fl

 utters, 

diminishes or extinguishes, especially when main burner 
ignites. Monitor appliance supply working pressure.

 

-

Check if supply piping size is to code. Correct all 
undersized piping.

Main burner 

fl

 ame is a 

blue, lazy, transparent 

fl

 ame.

Blockage in vent.

 

-

Remove blockage. In really cold conditions, ice buildup 
may occur on the terminal and should be removed as 
required.  To minimize this from happening again, it is 
recommended that the vent lengths that pass through 
unheated spaces (attics, garages, crawl spaces) be 
wrapped with an insulated mylar sleeve.  Prevent sleeve 
from sagging.  Contact your local authorized dealer for 
more information.

42.3B

!

WARNING

ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RAN OUT, 

WITH THE GLASS DOOR OPEN OR REMOVED.

TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE.

APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED.

DO NOT USE ABRASIVE CLEANERS.

Summary of Contents for BCDV42N

Page 1: ...ediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performe...

Page 2: ...IGID VENT COMPONENTS 23 4 3 1 HORIZONTAL AIR TERMINAL INSTALLATION 23 4 3 2 EXTENDED HORIZONTAL AIR TERMINAL INSTALLATION 23 4 3 3 VERTICAL AIR TERMINAL INSTALLATION 24 4 4 MOBILE HOME INSTALLATION 25...

Page 3: ...LOSURE CLEARANCES See the section FRAMING and MINIMUM MANTEL AND ENCLOSURE CLEARANCES for drywall or other combustible material See the sections VENTING and INSTALLATION See the sections INSTALLATION...

Page 4: ...trol compartments burners and circulating blower and its passageway in the appliance and venting system are kept clean The appliance and its venting system should be inspected before use and at least...

Page 5: ...vent sealed combustion product ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED PROVIDE ADEQUATE CLEARANCE FOR SERVICING AND OPE...

Page 6: ...eated The location of windows doors and the traffic flow in the room where the appliance is to be located should be considered If possible you should choose a location where the vent will pass through...

Page 7: ...ENT SUPERIEUR 2 BACK ARRIERE 0 VENT BOTTOM EVENT INFERIEUR 1 MANTEL MANTEAU 5 VENT HEAT SHIELD PROTECTEUR DE CONDUIT D VACUATION1 MAXIMUM HORIZONTAL EXTENSION L EXTENSION HORIZONTALE MAXIMALE 5 SEE IN...

Page 8: ...irestop vent pipe shield or attic insulation shield when penetrating interior walls floor or ceiling NOTE If for any reason the vent air intake system is disassembled reinstall per the instructions pr...

Page 9: ...e venting in conjunction with the various terminations use either the 5 foot vent kit GD420 or the 10 foot vent kit GD430 For optimum flame appearance and appliance performance keep the vent length an...

Page 10: ...TYPICAL VENT INSTALLATIONS 18 MAX 38 1 4 MIN PLUS RISE 35 1 2 40FT MAX 3FT MIN 16 MIN NOTE When terminating vertically the restrictor plate W500 0205 must be installed see RESTRICTING VERTICAL VENTS...

Page 11: ...riscope kit to locate the air termination above grade The periscope must be installed so that when final grading is completed the bottom air slot is located a minimum of 12 above grade The maximum all...

Page 12: ...om an adjacent wall including neighbouring buildings P 8 8 Roof must be non combustible without openings Q 3 3 See chart for wider wall dimensions R 6 6 See chart for deeper wall dimensions The termin...

Page 13: ...s the vertical rise equal to or greater than the horizontal run 3 times the vertical rise equal to or greater than the horizontal run 3 6 DEFINITIONS 14 2 For the following symbols used in the venting...

Page 14: ...HO 03 one 45 elbow two 90 elbows 135 03 225 135 2 7 FT HT HR HO 4 5 2 7 7 2 FT HT VT 7 2 8 15 2 FT Formula 1 HT VT 7 2 8 Formula 2 HT VT 40 FT 15 2 40 Since both formulas are met this vent configurati...

Page 15: ...45 elbow four 90 elbows 135 03 405 135 8 1 FT HT HR HO 5 5 8 1 13 6 FT HT VT 13 6 5 5 19 1 FT Formula 1 HT 4 2 VT 4 2 VT 4 2 x 5 5 FT 23 1 FT 13 6 23 1 Formula 2 HT VT 24 75 FT 19 1 24 75 Since both...

Page 16: ...elbow the following formulas apply Formula 1 HT VT Formula 2 HT VT 40 feet Example V1 5 FT V2 10 FT VT V1 V2 5 10 15 FT H1 3 FT H2 2 5 FT HR H1 H2 3 2 5 5 5 FT HO 03 one 45 three 90 elbows 135 03 45 2...

Page 17: ...e this formula is not met this vent configuration is unacceptable Formula 2 HT VT 40 FT 15 9 40 Since only formula 2 is met this vent configuration in unacceptable and a new fireplace location or vent...

Page 18: ...NECTION CANNOT SLIP OFF DO NOT CLAMP THE FLEXIBLE VENT PIPE RISK OF FIRE EXPLOSION OR ASPHYXIATION IMPROPER SUPPORT OF THE ENTIRE VENTING SYSTEM MAY ALLOW VENT TO SAG AND SEPARATE USE VENT RUN SUPPORT...

Page 19: ...gainst the firestop top and secure the two together Adjust the assembly to ensure it is tight to the vent Secure firestop to wall This restricts cold air from being drawn into the room or around the a...

Page 20: ...Determine the air terminal location cut and frame a square opening as illustrated in the ceiling and the roof to provide the minimum 1 clearance between the vent pipe and any combustible material Try...

Page 21: ...exterior wall and make weather tight by sealing with caulking not supplied D If more vent pipe needs to be used to reach the appliance couple them together as illustrated The vent system must be suppo...

Page 22: ...air terminal connector is properly centred within the flashing giving a 3 4 margin all around Fasten to the roof Do not nail through the lower portion of the flashing Make weather tight by sealing wit...

Page 23: ...using 3 self tapping screws Repeat using the outer rigid pipe C Insert the vent pipes through the firestop maintaining the required clearance to combustibles Holding the air terminal lettering in an...

Page 24: ...f the air terminal connector Place the flashing over the air terminal connector and slide it underneath the sides and upper edge of the shingles Ensure that the air terminal connector is properly cent...

Page 25: ...e to secure For free standing products contact your local authorized dealer distributor for the appropriate securing kit For mobile home installations the appliance must be fastened in place It is rec...

Page 26: ...PLY PIPE TO PREVENT DAMAGING GAS LINE ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED PURGING OF THE GAS SUPPLY LINE SHOULD BE...

Page 27: ...NIMUMS LISTED MUST BE CONSTRUCTED ENTIRELY OF NON COMBUSTIBLE MATERIALS MATERIALS CONSISTING ENTIRELY OF STEEL IRON BRICK TILE CONCRETE SLATE GLASS OR PLASTERS OR ANY COMBINATION THEREOF ARE SUITABLE...

Page 28: ...7 not supplied It is best to frame your appliance after it is positioned and the vent system is installed Use 2x4 s and frame to local building codes It is not necessary to install a hearth extension...

Page 29: ...rature requirements the enclosure space around and above the appliance must be left unobstructed See VENTING section 2 2 38 1 4 MINIMUM PLUS RISE 10 3 1 4 45 1 2 2 0 IF NON COMBUSTIBLE FINISHING IS US...

Page 30: ...stible mantel clearance can vary according to the mantel depth Use the graph to help evaluate the clearance needed Curtains above the appliance must not be positioned lower than the 5 distance require...

Page 31: ...CRATCH GLASS DO NOT OPERATE APPLIANCE WITH GLASS REMOVED CRACKED BROKEN OR SCRATCHED FACING AND OR FINISHING MATERIAL MUST NEVER OVERHANG INTO THE APPLIANCE OPENING 72 1A WARNING GLASS MAY BE HOT DO N...

Page 32: ...A Remove the upper louvres and open the glass door Remove the logs B Remove the two securing screws located on either firebox side C Place the left panel against the left side of the firebox ensuring...

Page 33: ...studs located on the burner with the holes on the bottom of the logs C Place the bottom of the left crossover log W135 0300 onto the stud on the left side of the log support The top of the log should...

Page 34: ...l will only glow when exposed to direct flame however care should be taken to not block the burner ports Blocked burner ports can cause an incorrect flame pattern Carbon deposits and delayed ignition...

Page 35: ...Attach and secure the variable speed switch using the nut provided Plug the harness cord into the receptacle The wire harness provided in this kit is a universal harness When installed ensure that any...

Page 36: ...ot burner to be lit until the thermo couple has cooled Allow approximately 60 seconds for the thermocouple to cool When lighting and re lighting the gas knob cannot be turned from pilot to off unless...

Page 37: ...3 P I P I L O T N O L O T HI L O F F O A B PILOT SCREW PILOT BURNER THERMOCOUPLE THERMOPILE 9 2 VENTURI ADJUSTMENT This appliance has an air shutter that has been factory set open according to the ch...

Page 38: ...be obstructed A In order to properly clean the burner and pilot assembly remove the logs rocks and or glass to expose both assemblies B Keep the control compartment media burner air shutter opening a...

Page 39: ...the finish and little maintenance is required just wipe clean as needed Prolonged high temperature burning with the door ajar may cause discolouration on plated parts NOTE The protective wrap on plat...

Page 40: ...ING THERMOCOUPLE SUPPLIED BY WOLF STEEL LTD WARNING COMPONENTS REF NO PART NO DESCRIPTION 1 W357 0001 PIEZO IGNITER 2 W680 0004 THERMOPILE 3 W680 0005 THERMOCOUPLE 4 W010 0800 NATURAL GAS PILOT ASSEMB...

Page 41: ...38 W010 0453 ROOF SUPPORT 39 W263 0065 ROOF FLASHING W236 0066 W236 0067 ACCESSORIES REF NO PART NO DESCRIPTION 40 W573 0007 10 3OZ TUBE HIGH TEMP SEALANT 41 W175 0166 5 COUPLER 41 W175 0002 8 COUPLER...

Page 42: ...KB35 VARIABLE SPEED SWITCH 57 GA 566 HOT AIR DISTRIBUTION KIT 58 W690 0005 THERMOSTAT 110V FOR USE WITH GA 566 ONLY 59 GA 70 EXTENSION KIT 5FT 60 GA 72 HOT AIR EXHAUST KIT 61 W175 0211 CONVERSION KIT...

Page 43: ...valve Faulty valve Replace Pilot burning no gas to main burner gas knob is on HI wall switch thermostat is on Thermostat or switch is defective Connect a jumper wire across the wall switch terminals i...

Page 44: ...on HI Outlet pressure can be checked the same as above using screw B Gauge should read 3 5 water column for natural gas or 10 water column for propane Check that main burner is operating on HI AFTER T...

Page 45: ...eadaches Appliance is spilling Ensure exhaust bracket gasket seal Check door seal and relief flap seal Check for chimney blockage Check that chimney is installed to building code Room is in negative p...

Page 46: ...caused by environmental conditions such as rooftops buildings nearby trees hills mountains inadequate vents or ventilation excessive venting configurations insufficient makeup air or negative air pre...

Page 47: ...47 W415 0778 D 09 13 12 14 0 SERVICE HISTORY 43 1...

Page 48: ...48 W415 0778 D 09 13 12...

Reviews: