
5
Selection of installation equipment
Drill holes on the table surface according to the sizes shown in the drawing.
For the purpose of installation and use, a minimum of 50 mm space shall be
preserved around the hole.
Be sure the thickness of the table surface is at least 30mm. Please select
heat-resistant table material to avoid larger deformation caused by the heat
radiation from the hotplate.
As shown in Figure (2)
Under any circumstances, make sure the induction hotplate is well ventilated
and the air inlet and outlet are not blocked.
Ensure the induction hotplate is in good work state.
As shown in Figure (3)
Figure (3)
Figure (2)
5 cm m
ini
5cm m
ini
5cm m
ini
56 cm
49 cm
Air intake
mini 5 cm
mini 760mm
mini 2 cm
Air exit
mini 5 mm
Summary of Contents for CECP701FSA
Page 1: ...Manuel d instructions de la PLAQUE DE CUISSON INDUCTION CECP701FSA ...
Page 24: ...Figure 4 24 ...
Page 26: ...1 4 2 3 Figure 6 26 ...
Page 33: ...33 ...
Page 34: ...34 ...
Page 35: ...35 ...
Page 36: ...36 ...
Page 37: ...37 E3 E4 F0 F2 E1 E2 E5 E6 F3 F8 E IGBT F9 F ...
Page 38: ...38 ...