![CONTINENTAL EDISON BANDEAU HP F1 Service Manual Download Page 65](http://html1.mh-extra.com/html/continental-edison/bandeau-hp-f1/bandeau-hp-f1_service-manual_2656922065.webp)
HP F1 PANEL
CUSTOMER
SUPPORT
SERVICE MANUAL
MACHINE IS NOT DRYING
Is compressor
overload
protector open
circuit?
Is connection of
compressor
connector
correct?
Wait temperature of the compressor surface
decrease room temperature and check again.
Are the measured
resistance values
through the
compressor connector
correct?
Is drum rotating
CW
Change compressor NTC
Change the compressor
Check the drum is not rotating alg.
NO
YES
YES
YES
YES
NO
NO
NO
NO
Is machine
power correct?
YES
NO
Check the compressor gas
YES
Is the Filter and
Condenser
Clean?
Clean Filter and / or Condenser
NO
NO
Make Electrical Connection
Are the measured
resistance values
through the Comp.
NTC Correct
?
Is the compressor
cable transmitted the
current to e. card ?
EVET
Change the cable tree
HAYIR
User should be informed about
the machine.