U N D E R F L O O R H E A T I N G
3. Installation
Make your jumper settings
*TPI will determine the pattern of your heating periods and will adjust it so that the temperature point will be maintained longer.
**NSB will only operate if there is a master thermostat set on the wiring centre. If there is no master set, there’s no need to remove the jumper.
Make sure that
the thermostat
dial is set in
position 1.
Insert the batteries.
If the Quantum dial
thermostat-RF
flashes green,
but you need to re-pair it, read
the Reset section.
Jumper
Feature
Default
PI*/SPAN
TPI (jumper ON) or Span
0.5°C (remove jumper)
TPI ON
NS
B**
Night Setback ON (jumper
ON) or OFF (remove jumper)
ON
Setback
value
-2°C (jumper ON) or -4°C
(remove jumper)
-2°C for heating
NSB
TPI
2°C
ON
ON
4°C
OFF
OFF
Jumper ON
Jumper OFF
1
2
3
4
5