![Contigo 6601H Installation Manual Download Page 7](http://html1.mh-extra.com/html/contigo/6601h/6601h_installation-manual_2656620007.webp)
Red
LED Error Codes
1
st
Digit
2
nd
Digit
Error Condition
1
1
License key has expired.
Please contact Contigo Support.
1
2
Low supply voltage.
Ensure that the vehicle battery is supplying
adequate voltage. Contact Contigo Support if the error persists.
1
3
Data usage exceeded.
Please contact Contigo Support.
2
1
Modem module fault.
Please contact Contigo Support.
2
2
No SIM inserted.
Please contact Contigo Support.
2
3
No cellular signal. *
2
4
Network not found.
Please contact Contigo Support to verify the SIM
activation.
2
5
Last data session failed. *
2
6
GPRS not attached.
Please verify beacon activation.
3
1
GPS module fault.
Please contact Contigo Support.
3
2
GPS antenna fault. *
3
3
GPS not tracking any satellites. *
3
4
GPS no fix (<3 satellites). *
3
5
GPS has no time. *
4
2
Data transfer failed. *
* These issues may be caused by an incorrectly positioned beacon. If the device is connected properly and has
an unobstructed view of the sky, and the error persists, please contact Contigo Support.
Warnings and Known Issues
•
It is important that the molex connector is installed fully into the beacon port, and that the device is firmly
attached to the vehicle. Excessive vibrations from a loose installation can cause incorrect results.
•
The Contigo 6600H/6601H is not a waterproof or sealed device. Care must be taken to ensure the device
is kept away from water or any other liquids.
•
The Contigo 6600H/6601H may be incompatible with certain models of vehicles. For more information
please contact your Contigo dealer.