background image

1500W DMX smoke machine with HF remote control and Timer

Page  6

English

4-3 : The control panel

The control panel features 6 buttons: 

Function

Timer

Up

Down

Volume

 et 

Manual

.

The display will indicate 

 once the 

preheating process has been completed, W meaning the 

device is waiting for information from the remote control.

1 - 

Once the display indicates 

, press 

 until it indicates 

.

This function allows you to use the 

 buttons 

to adjust the interval between smoke projections (from 1 

to 200 seconds).

2 - 

Once the display indicates 

, press 

 

twice

. The display will then indicate 

. This function allows you to use the 

 buttons to adjust the duration of smoke 

projections (from 1 to 200 seconds).

3 - 

Once the display indicates 

, press 

 

three times

. The display will then indi-

cate 

. This function allows you to use the 

 buttons to configure the smoke quantity in 

Timer mode (from 1 to 100%). Press the 

 button 

to deactivate the Timer mode. Press it again to activate 

it.

4 - 

Once the display indicates 

, press 

 

four times

. The display will then indicate

. This function allows you to adjust the 

smoke output in Volume mode, via the 

 but-

tons. Press 

 to deactivate the Volume function. 

Press again to reactivate.

5 - 

Once the display indicates 

, press 

 

five times

. The display will then indicate

. This function allows you to configure 

the DMX address via the 

 buttons.

6 - 

Once the display indicates 

, press 

 

six times

. The display will then indicate 

. This function allows you to activate or       

deactivate the remote control via the 

 but-

tons.

7 - 

Once the display indicates 

, press 

and hold 

 to force the smoke output at 100%. 

The smoke output will be deactivated as soon as you 

release 

.

8 - 

Your Smotec1500 features an optical level sensor. 

The pump will automatically stop if the fluid level gets 

too low, the display will then indicate 

Pour more fluid into the tank and press 

 until 

 disappear.

9 - 

If you do not wish using the optical sensor, 

press 

 

seven times

 as the display indi-

cates 

. The display will then indicate 

. Use the 

 or 

 buttons to 

deactivate the optical sensor. The display will then indi-

cate 

. Proceed in the reverse order 

to reactivate it.

10 - 

Once the pre-heating process has been completed, 

the display will indicate the sensor and remote control 

status as follows:

- If the remote control is activated, the display will indi-

cate: 

.

- If the optical sensor is activated, the display will indi-

cate: 

.

- If both functions aforementioned are activated, the          

display will indicate : 

.

- If both functions are deactivated, the display will indi-

cate: 

.

Summary of Contents for Smotec 1500

Page 1: ...USER GUIDE 9577 December 2009 Version 1 0 1500W DMX smoke machine with HF remote control and Timer...

Page 2: ...this product or other property WARNING This unit contains no user serviceable parts Do not open the housing or attempt any maintenance by yourself In the unlikely even your unit may require service p...

Page 3: ...product away from any heat source such as a heaters amplifiers hot plates etc 10 Electric power supply This product can only be operated according to a very specific voltage These information are spe...

Page 4: ...ailer immediately 1 Power cord 2 Remote control Please refer to the chapter dedicated to the remote control further in this guide for more details 3 DMX outputs 3 and 5 pin XLR sockets allowing you to...

Page 5: ...ne for the receiver to maintain a proper connection with the remote control 8 Circuit breaker Protects the Smotec1500 against overcurrent 9 HF Antenna Receives the signals emitted by the remote contro...

Page 6: ...function Press again to reactivate 5 Once the display indicates press five times The display will then indicate This function allows you to configure the DMX address via the buttons 6 Once the display...

Page 7: ...s hour at 100 Electronic management of fluid quantities Remote control On Off Remote control batteries A27S DC 12V Preparation Fill the tank with smoke fluid We strongly recommend to use the Contest F...

Page 8: ...s to modifications without prior notice That is why technical specifications and the products physical configuration might differ from the illustrations Make sure you get the latest news and updates a...

Reviews: