Contemporary Research ICC1 Product Manual Download Page 1

 

17630 Davenport Rd, Suite113 
Dallas, TX  75252  USA 

 

Tel:   972.931.2728 

888.972.2728      

Fax:   972.931-2765     
Web:   www.crwww.com 

www.contemporaryresearch.com 

Product Manual 

 

ICC1/ICC2/ICW 

Smart TV Controller, Rear Mount 
Ver. 5.5  January 20, 2003 

 
 
 
 
 
 

   

 

 
 
 

Summary of Contents for ICC1

Page 1: ...ort Rd Suite113 Dallas TX 75252 USA Tel 972 931 2728 888 972 2728 Fax 972 931 2765 Web www crwww com www contemporaryresearch com Product Manual ICC1 ICC2 ICW Smart TV Controller Rear Mount Ver 5 5 January 20 2003 ...

Page 2: ...nd Smart TV control 6 RF Coax and iCC Net Operation ICC2 ICC1 6 iCW Net Connection ICW 6 Using the IC RC Remote for On Screen Menus 6 On Screen Setup Menus 7 RS 232 Control Protocol 8 Overview 8 Command String Structure 8 RS 232 Commands 9 RS 232 Responses 12 Response String Structure 12 iC Net Zones 14 System Map 15 Typical RF and ICC Net Signal Flow 16 iCW Net Wiring 17 Mounting 18 Safety Instru...

Page 3: ...ctive text menus and system feedback using TV s onboard character generator o Receives wireless commands from IC RC IR remote using TV s IR sensor o Delivers absolute volume control for level and mute o Manages channel access using list of available channels tuning ring in controller memory o Delivers absolute power control with on off feedback from TV o Low loss internal RF tap saves amplificatio...

Page 4: ...sent Error LED Red LED indicates a problem within the unit Connections ICC2 ICC1 RF Out F female 75 ohm impedance RF to TV less than 1 5 dbmV loss RF In iCC Net F female 75 ohm impedance RF from CATV system iCC Net Carried over the same RF coax connection as TV channels Receive ICC2 ICC1 Mid band VHF 74 7MHz sent from ICC HE Head End Network Controller 25 to 35 dBmV signal level Transmit ICC2 only...

Page 5: ...ch to GND 1 GND 2 Output 1 3 Output 2 4 12 VDC Closure 1 Pins 2 4 to provide DC on off for optional buzzer Closure 2 Pins 1 3 for dry contact to external power relay AMX PC1 or similar Includes Smart TV data link cable Mounting hardware RF Loop Cable ICC models only 12 VDC Power Supply Not included for international shipments or if powered by TV ...

Page 6: ...le into the RF In jack 2 If the iCC Net signal is operating the Net LED will blink once per second 3 Connect RF loop cable included from RF Out to TV s RF input iCW Net Connection ICW 1 Plug the iCW Net RJ 45 connector into the iCW Net input 2 If the iCW Net signal is operating the Net LED will blink once per second 3 Connect the CATV RF Coax cable to the TV s RF input Using the IC RC Remote for O...

Page 7: ...on After about 5 seconds the TV will drop communication with the TV controller and revert to stand alone TV mode At this point the installer can switch to the TV Mode on the remote control and then adjust the TV setup parameters To re enable smart port press Record on IC RC 65487 Initialize to factory default settings Power on unlocked display channel 11 channel ring set to 4 5 and 11 Group 0 Note...

Page 8: ...l system Zones 1 16 are used for CR TV Controllers Video Display Controllers and Tuners As it s unlikely any system will use all 4000 devices this may be a good device standard for your system as well The Remote RS 232 port on the Head End Network Controller can communicate from 1200 to 38 4K baud The factory default setting is 19 2K baud 8 data bits No parity and 1 stop bit Command String Structu...

Page 9: ...required when using V5 5 or newer firmware Ts Qs The following T series channel commands select a channel and display the channel label on the TV while Q series commands don t show the on screen text T Channel Up TU A5 dh dl 2 TU 6 bytes Tunes to next channel up in Tune Ring T Channel Dwn TD A5 dh dl 2 TD 6 bytes Tunes to next channel down in Tune Ring Force T Channel TC A5 dh dl 3 TC channel 7 by...

Page 10: ... briefly when the channel is selected if the feature has been activated by Setup command TM Ex1 A5 dh dl 3 TN 7 PBS TV displays PBS when 7 is selected Ex2 A5 dh dl 3 TN 7 Clears alpha label for channel 7 Ex3 A5 dh dl 3 TN 0 0 Clears all alpha labels Display Label TC A5 dh dl 2 TC 6 bytes Display current channel label for about 15 sec Closures Y A5 dh dl 3 Y I 0 Port 7 bytes Turns the two internal ...

Page 11: ... a carriage return which will advance CG to the next line first space on the right Start Line 1 11 Text Color 1 7 White Text Background Color 0 7 Transparent no background Full screen background 0 normal insert over video 1 blank screen blue Size and Shadow 0 3 small text with drop shadow Time Out 0 15 second display 1 persistent Persistent text stays on screen until the next DM command a new Menu...

Page 12: ...ies of multiple commands or parameters are set apart by brackets Commas separate the bytes but are not part of the protocol Double quotes enclose the command string but are not part of the protocol Command format dh dl nrb rb1 para1 rbN Starts the response dh The zone or high order byte of the device dl The unit or low order byte of the device 0 for global zone nrb The number of response bytes to ...

Page 13: ... and low bytes are in msh and msl Menu Parameter high and low bytes are in mph and mpl A Menu command is initiated by pressing the Menu key followed by a numeric entry then the Enter or Channel Up key During the Menu process the Channel Down key acts as a backspace or delete key Some selections that need only a single numeric entry and will have a parameter value of zero 0 Those keys are 0 8 9 18 ...

Page 14: ...reating multiple commands there would be a long delay between the first and last command One command instant response is easier As we noted before ABC Media Retrieval Systems reserve Zone 0 for devices used in the central control system 1 15 for iC Net devices This structure may be useful for your application or you could use Zone 0 just like any other iC Net zone Zone First Device Last Device Vir...

Page 15: ...tion whichever suits the application iC Net Zone Zone Room Device 1 W 1st Floor 256 W151 257 W152 258 W153 259 W154 260 2 W 2nd Floor 512 W251 513 W252 514 W253 515 W254 516 3 E 1st Floor 768 E151 769 E152 770 E153 771 E154 772 4 E 2nd Floor 1024 E251 1025 E252 1024 E253 1025 E254 1026 5 Coffee Areas 1280 G100 1281 G150 1282 G151 1283 6 Day Care 1536 TV 1 1537 TV 2 1538 7 Hallways 1792 W1 1793 W2 ...

Page 16: ...RF and ICC Net Signal Flow The diagram below shows the structure of a typical Contemporary Research media retrieval system One of the key aspects for iCC Net communication is to provide a forward and return sub channel path for data if you re using ICC2 2 way TV Controllers ...

Page 17: ...ibute signals to multiple iCW Net devices Open wiring runs do not need termination Head End iCW Net 1 Screw Terminals iCW Series iCW Net RJ 45 PWR RXD RXD TXD TXD GND 8 7 6 5 4 3 2 1 TXD TXD GND RXD RXD NC NC NC 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 Punch down Blocks RJ 45 Harmonicas Wall Plates RXD RXD GND TXD TXD NC NC NC 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 BRN WHT WHT BRN GRN WHT WHT BLU BLU WHT WHT GRN ...

Page 18: ...you ll mount the TV Controller on the right side of the TV towards the rear of the rear hood Make sure you minimize blockage of any vent slots in the process Drill pilot holes 36 0 106 or 7 64 0 109 between 6 to 6 9 16 apart Attach TV Controller using the two 6 self tapping screws included ...

Page 19: ...ire or electric shock 7 Object and Liquid Entry Never push objects of any kind into this product through openings as they may touch dangerous voltage points or short out parts resulting in a fire or electric shock Never spill liquid of any kind on the product 8 Servicing Do not attempt to service this product yourself as opening or removing covers may expose you to dangerous voltage or other hazar...

Page 20: ...whether damages are sought or a claim is made under this warranty or as a tort claim including negligence and strict product liability a contract claim or any other claim This limitation of liability cannot be waived or amended by any person This limitation of liability will be effective even if CR or an authorized representative of CR has been advised of the possibility of any such damages Some s...