Contemporary Research ICC-PRZ Product Manual Download Page 7

Contemporary 

Research    

7    

ICC-PRZ Smart TV Controllers

 

On-Screen Setup Menus 

The remaining installation steps use the IR remote and the TV’s built-in character generator.  

1.

 

Touch 

Menu

, then 

999

, then 

Enter

2.

 

The text 

CR MENU>

 should appear on the screen. 

3.

 

Key in one of the commands shown below, then press 

Enter

 to activate. 

4.

 

Note that, in Menu mode, the 

Channel Down 

key acts as a backspace/delete key and 

Channel Up

 

can act as an 

Enter

.  

 

Command Function 

All 

The following commands are used for all units 

45677 

Display firmware base data (variations for LG models) 

.

45678 

Display firmware version 

45679 

Display the unit’s Device #. At this point, you can use the Channel Down key as a 

Delete key, enter a new device # with the remote’s numeric keypad, then hit Enter 

to save the new number. 

65478 

Reset unit, similar to disconnecting power then restarting. 

65479

 

Disable smart port communication. After about 5 seconds the TV will drop 

communication with the TV controller and revert to stand alone TV mode. At this 

point, the installer can switch to the TV Mode on the remote control, and then adjust 

the TV setup parameters. To re-enable smart port, press 

Record

 on IC-RC. 

65487 

Initialize to factory default settings: Power on, unlocked, display channel 11, channel 

ring set to 4, 5, and 11, Group 0. Note that this command works even if TV power is 

off or control is locked out. 

65482 Shows 

Net RX

 if receiving the iC-HE’s “heartbeat” pulse once per second, 

!NET RX

 

if not. Also displays receive signal strength in the ICC2. 

ICC2 

The following commands are used for the ICC2 only 

65480 

Enable constant Net transmit to the Head-End. This is used for measuring the signal 

strength of the ICC2 unit’s RF output. Press Enter to stop transmitting, or the unit 

will automatically stop after 50 seconds. 

65481 

Display ICC2 transmitter frequency control voltage – should be 2000 - 3150. 

65483 

Display DF transmitter frequency deviation – should be 245 - 300. 

Summary of Contents for ICC-PRZ

Page 1: ...enport Road Suite 113 Dallas TX 75252 Phone 972 931 2728 Toll Free 888 972 2728 Fax 972 931 2765 E Mail Sales crwww com Website www crwww com Product Manual ICC PRZ Smart TV Controllers Ver 1 6 September 29 2008 ...

Page 2: ...d Smart TV control 6 RF Coax and iCC Net Operation ICC2 ICC1 6 Using the IC RC Remote for On Screen Menus 6 On Screen Setup Menus 7 RS 232 Control Protocol 8 Overview 8 Command String Structure 8 RS 232 Commands 9 RS 232 Responses 12 Response String Structure 12 iC Net SmartZones 14 System Map 15 Typical RF and ICC Net Signal Flow 16 Mounting 17 Safety Instructions 18 Limited Warranty and Disclaim...

Page 3: ...el access using list of available channels tuning ring in controller memory o Delivers absolute power control with on off feedback from TV o Low loss internal RF tap saves amplification and installation costs Interacts with the Smart TV s internal IR sensors character generator and tuner Networks with up to 4 000 TVs through the ICC HE or ICW HE Head End Network Controller HE o ICC1 units receive ...

Page 4: ...en LED for iC Net bus flashes once per second if receiving communication TV COM LED Yellow LED flashes when IR data received stays off when Smart link is not present Error LED Red LED indicates a problem within the unit Connections RF Out F female 75 ohm impedance RF to TV less than 1 5 dbmV loss RF In iCC Net F female 75 ohm impedance RF from CATV system iCC Net Carried over the same RF coax conn...

Page 5: ...ns 2 4 to provide DC on off for optional buzzer Closure 2 Pins 1 3 for dry contact to external power relay AMX PC1 or similar Includes Smart TV data link cable Mounting hardware RF Loop Cable ICC models only 12 VDC Power Supply Not included for international shipments or if powered by TV Contemporary Research 5 ICC PRZ Smart TV Controllers ...

Page 6: ...ICC2 ICC1 1 Connect the CATV RF Coax cable into the RF In jack 2 If the iCC Net signal is operating the Net LED will blink once per second 3 Connect RF loop cable included from RF Out to TV s RF input Using the IC RC Remote for On Screen Menus In order to complete the setup you ll need the IC RC IR Remote to use the On Screen Menus Typically the remote is shipped ready to communicate to Smart TV J...

Page 7: ...e smart port communication After about 5 seconds the TV will drop communication with the TV controller and revert to stand alone TV mode At this point the installer can switch to the TV Mode on the remote control and then adjust the TV setup parameters To re enable smart port press Record on IC RC 65487 Initialize to factory default settings Power on unlocked display channel 11 channel ring set to...

Page 8: ...tem Zones 1 16 are used for CR TV Controllers Video Display Controllers and Tuners As it s unlikely any system will use all 4000 devices this may be a good device standard for your system as well The Remote RS 232 port on the Head End Network Controller can communicate from 1200 to 38 4K baud The factory default setting is 19 2K baud 8 data bits No parity and 1 stop bit Command String Structure Ch...

Page 9: ...the channel label on the TV while Q series commands don t show the on screen text T Channel Up TU A5 dh dl 2 TU 6 bytes Tunes to next channel up in Tune Ring T Channel Dwn TD A5 dh dl 2 TD 6 bytes Tunes to next channel down in Tune Ring T Channel Prev TP A5 dh dl 2 TP 6 bytes Tunes to previous channel in Tune Ring Force T Channel TC A5 dh dl 3 TC channel 7 bytes Tunes to a specific channel 124 RGB...

Page 10: ... if the feature has been activated by Setup command TM Ex1 A5 dh dl 6 TN 7 PBS TV displays PBS when 7 is selected Ex2 A5 dh dl 3 TN 7 Clears alpha label for channel 7 Ex3 A5 dh dl 4 TN 0 0 Clears all alpha labels Display Label TC A5 dh dl 2 TC 6 bytes Display current channel label for about 15 sec Closures Y A5 dh dl 3 Y I 0 Port 7 bytes Turns the two internal closures on and off Closure 1 is typi...

Page 11: ...riage return which will advance CG to the next line first space on the right Start Line 1 11 Text Color 1 7 White Text Background Color 0 7 Transparent no background Full screen background 0 normal insert over video 1 blank screen blue Size and Shadow 0 3 small text with drop shadow Time Out 0 15 second display 1 persistent Persistent text stays on screen until the next DM command a new Menu or ch...

Page 12: ...f multiple commands or parameters are set apart by brackets Commas separate the bytes but are not part of the protocol Double quotes enclose the command string but are not part of the protocol Command format dh dl nrb rb1 para1 rbN Starts the response dh The zone or high order byte of the device dl The unit or low order byte of the device 0 for global zone nrb The number of response bytes to follo...

Page 13: ...ow bytes are in msh and msl Menu Parameter high and low bytes are in mph and mpl A Menu command is initiated by pressing the Menu key followed by a numeric entry then the Enter or Channel Up key During the Menu process the Channel Down key acts as a backspace or delete key Some selections that need only a single numeric entry and will have a parameter value of zero 0 Those keys are 0 8 9 18 20 30 ...

Page 14: ...assles of creating multiple commands there would be a long delay between the first and last command One command instant response is easier As we noted before ABC Media Retrieval Systems reserve Zone 0 for devices used in the central control system 1 15 for iC Net devices This structure may be useful for your application or you could use Zone 0 just like any other iC Net zone Zone First Device Last...

Page 15: ...whichever suits the application iC Net Zone Zone Room Device 1 W 1st Floor 256 W151 257 W152 258 W153 259 W154 260 2 W 2nd Floor 512 W251 513 W252 514 W253 515 W254 516 3 E 1st Floor 768 E151 769 E152 770 E153 771 E154 772 4 E 2nd Floor 1024 E251 1025 E252 1024 E253 1025 E254 1026 5 Coffee Areas 1280 G100 1281 G150 1282 G151 1283 6 Day Care 1536 TV 1 1537 TV 2 1538 7 Hallways 1792 W1 1793 W2 1794 ...

Page 16: ...cture of a typical Contemporary Research media retrieval system One of the key aspects for iCC Net communication is to provide a forward and return sub channel path for data if you re using ICC2 2 way TV Controllers Contemporary Research 16 ICC PRZ Smart TV Controllers ...

Page 17: ...owards the rear of the rear hood Make sure you minimize blockage of any vent slots in the process Drill pilot holes 36 0 106 or 7 64 0 109 between 6 to 6 9 16 apart Attach TV Controller using the two 6 self tapping screws included Contemporary Research 17 ICC PRZ Smart TV Controllers ...

Page 18: ... electric shock 7 Object and Liquid Entry Never push objects of any kind into this product through openings as they may touch dangerous voltage points or short out parts resulting in a fire or electric shock Never spill liquid of any kind on the product 8 Servicing Do not attempt to service this product yourself as opening or removing covers may expose you to dangerous voltage or other hazards Ref...

Page 19: ...r damages are sought or a claim is made under this warranty or as a tort claim including negligence and strict product liability a contract claim or any other claim This limitation of liability cannot be waived or amended by any person This limitation of liability will be effective even if CR or an authorized representative of CR has been advised of the possibility of any such damages Some states ...

Reviews: