Contemporary Controls CANISA Installation Manual Download Page 2

SPECIFICATIONS 

Power Requirements 

ISA Bus 

CANbus 

+5 V 

+

24

 V 

80 mA 

80

 mA 

Environmental 

Operating  temperature: 

0°C to +60°C 

Storage temperature: 

-40°C to +85°C 

Data Rates 

50 kbps, 100 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps 

Dimensions 

4.20"  x  6.50"  (106 mm x 165 mm) 

Shipping Weight 

1 lb. (.45kg) 

I/O Mapping — BasicCAN 

The CANISA can occupy any of the following 32-byte blocks of I/O space. 

000  020  040  060  080  0A0  0C0  0E0  100  120  140  160  180  1A0  1C0  1E0 
200  220  240  260  280  2A0  2C0  2E0  300  320  340  360  380  3A0  3C0  3E0 

I/O Mapping — PeliCAN 

The CANISA can occupy any of the following 128-byte blocks of I/O space. 

000  080  100  180  200  280  300  380 

Interrupt Lines 

Supports selection of IRQ3 through IRQ15 

Compatibility 

Compliant with CAN 2.0A and CAN 2.0B 

Regulatory Compliance 

CE Mark 
C

FR 47, 

Part 15 Class A 

TD990520-0I

E

2

Summary of Contents for CANISA

Page 1: ...SJA1000 maintains extended frame passivity while in the BasicCAN mode The SJA1000 features a 16 MHz clock a larger receive buffer and better acceptance filtering including the ability to extend the ac...

Page 2: ...The CANISA can occupy any of the following 32 byte blocks of I O space 000 020 040 060 080 0A0 0C0 0E0 100 120 140 160 180 1A0 1C0 1E0 200 220 240 260 280 2A0 2C0 2E0 300 320 340 360 380 3A0 3C0 3E0 I...

Page 3: ...y available ISA bus slot Once the CANISA is mounted it can be attached to the CANbus with either the screw terminals or the DB 9 connector To facilitate use of the screw terminals a mating female conn...

Page 4: ...and the alternative impedance connected to screw terminals CAN_H and CAN_L Interrupts Jumper block JP6 makes available all possible interrupt selections Interrupt 5 has been chosen as the default I O...

Page 5: ...mper installed Table 1 32 byte Addressing for BasicCAN RA S4 S3 S2 S1 S0 I O Address 000 020 040 060 080 0A0 0C0 0E0 100 120 140 160 180 1A0 1C0 1E0 200 220 240 260 280 2A0 2C0 2E0 300 320 340 360 380...

Page 6: ...stributed System define additional services of the seven layer OSI model Both of these protocols use CAN circuitry and therefore comply with the data link layer defined by CAN Medium access control MA...

Page 7: ...specification during the warranty period CC will at its option repair or replace the product at no charge The customer is however responsible for shipping the product CC assumes no responsibility for...