Cold Air Drafts 

In cold climates, you must take special precautions and follow the cold climate installation instruction section of 
your installation manual. 
 
If cold air drafts are present when the fireplace is not in operation, you should check the following: 
 

 If air is coming out of the fireplace opening, check to see that the damper is in the closed position. 

 If air coming in around the sides of the fireplace, between the fireplace face and the wall, check to see that 

the fireplace frame has been caulked to the enclosure frame. 

 Outside air must be introduced into the chase cavity to cool the double-wall chimney. Therefore, insulation 

should be installed on the fireplace face wall. 

 

 
 
 
 
 

Whistling Noise (wood-burning Contempo fireplaces with glass door installed) 

During the summer, if your wood-burning fireplace has been equipped with a glass door and begins to make a 
whistling noise while an evaporative cooler is running, first make sure the damper is closed (this does not apply 
to  gas-converted  or  all-gas  fireplaces),  then  open  a  window  that  is  close  to  the  fireplace  about  one  inch.  The 
noise  is  caused  by  forced  air  around  the  door;  opening  a  window  will  alleviate  the  pressure  and  should 
completely solve the problem. 
 

Ash Disposal 

Ashes should be placed in a metal container with a tight-fighting lid. Pending final disposal, the closed container 
of  ashes  should  be  placed  on  a  non-combustible  floor  or  on  the  ground,  well  away  from  all  combustible 
materials. If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in 
the closed container until all cinders have thoroughly cooled. 
 
Keep all combustible furnishings a considerable distance from the fireplace. 
 
 
 
 
Contempo Fireplace Accessories & Options 
 

 

Contempo Fireplace Accessories & Options 

 

Glass Door 

Glass doors are available as an optional accessory for use on all wood-burning Contempo Fireplace models. It 
is required for use when the fireplace has been converted to a ceramic gas log system. Refer to the fireplace 
installation instructions as to which model fits your fireplace. 
 
 
 

 

 

 

NOTE:

 After you have followed the precautions listed above, there may still be some cold air draft coming 

through other areas: this may be due to the circumstances beyond the manufacturer’s control, such as air 
flow around the structure, tightness of the house (creating negative pressure), etc.                                                                    

 

WARNING: 

NEVER BLOCK A VENT OR GRILLE OF THE FIREPLACE. THESE ARE IMPORTANT TO 

THE  COOLING  OF  THE  FIREPLACE  AND  ASSURE  SAFE  AND  PROPER  OPERATION  AS 
DESIGNED. 
 

WARNING:

  THE  CONTEMPO  WOOD-BURNING  FIREPLACE  HAS  NOT  BEEN  TESTED  FOR  USE 

WITH  GLASS  DOORS.  THE  DOOR  MAY  BE  INSTALLED  TO  PREVENT  AIR  LOSS,  BUT  SHOULD 

NOT

 BE CLOSED WHEN FIRE IS PRESENT. 

Summary of Contents for PFM36

Page 1: ...r you are building a fire inside your home so it is important that you observe these guidelines This general purpose guide is supplied for use with all wood burning and gas converted Contempo fireplac...

Page 2: ...ng Your Fireplace This OMNI Testing Service listed fireplace has been tested to UL 127 test standards and is well insulated for safe clearances to combustible construction materials used to build your...

Page 3: ...hearth you will prevent the chance of having a log spill or rollout of the fireplace DO NOT OVERLOAD THE FIREPLACE Piling excessive wood on your grate will not increase efficiency and could cause smok...

Page 4: ...the house After cleaning is completed open the damper and collect the debris in a trash container A professional chimney sweep has all the tools and experience necessary to do a complete job and shoul...

Page 5: ...laced in a metal container with a tight fighting lid Pending final disposal the closed container of ashes should be placed on a non combustible floor or on the ground well away from all combustible ma...

Page 6: ...equired that the damper be secured in a permanently open position It must not be closed Gas Only Converted Fireplace Lighting instructions vary with the type of valve installed see valve manufacturer...

Page 7: ...SE Albuquerque NM 87123 phone 505 291 0500 fax 505 291 9317 For future reference please fill out the following information the model and serial numbers can be found on the rating plate in the firebox...

Page 8: ...TY VALID CONTEMPO LLC WILL NOT BE RESPONSIBLE FOR ANY ASSERTED DEFECT WHICH HAS BEEN RETURNED DUE TO NORMAL WEAR MISUSE ABUSE OR REPAIR OR ALTERATION MADE OR SPECIFICALLY AUTHORIZED BY ANYONE OTHER TH...

Reviews: