Hardware RAID Setup
—
VPC-3100-G Series Reference Manual
-
88
-
3.
Switch Settings
Dip switch: S1
S1
Function
Normal state (Factory default setting)
Switches 1- 3 OFF / R
emaining Switches
OFF
Setting 1 (mirroring configuration information initialization)
Switches 1, 3 ON, Switch 2 OFF / R
emaining Switches
OFF
Setting 2 (error sector detection and restoration)
Switch 2 ON, Switches 1, 3 OFF /
Remaining Switches
OFF
CUATION
Be certain to turn the power supply OFF before setting the DIP switch.
In addition, do not use any settings other than those listed above.