Ver.1.00
RRY-16CX-USB
4
Figures shows the output circuit at the interface section of the
board. The signal output section uses a relay contact method
to send signals to the external device.
Output Circuit
CAUTION
When the power turned on, all outputs are reset to OFF.
Example of Connection
Output a "1" to a bit will light the LED that is connected to the
related relay output. On the other hand, output a "0" to the bit
will switch the LED off.
This product must be connected with 5VDC power supply (in a
self-powered state). Connect with 5VDC power supply by
using +5VDC input pin.
When using the attached AC adapter [POA200-20-2], please
connect directly to the input terminals. When the
accompanying power connector (MC1,5/3-ST-3,5, suitable
cable: AWG28 - 16) is used to supply power to this unit, strip
the end of the suitable cable and insert it to the power
connector before firmly securing it using a screw.
CAUTION
- Connect 5VDC power supply to the main unit. Next, connect the
USB cable to the PC. Do not turn it on or off when using. If you
remove, USB cable is first and then 5VDC power supply.
- When the USB module is not used, leave the AC adapter unplugged.
- Continuously using the AC adapter heated affects its life.
- Use the AC adapter not in a closed place but in a well-ventilated
place not to be heated.
- Do not remove the power connector [MC1,5/3-ST-3,5] attached to the
AC adapter.
セ
ル フ パ ワ ー
用 の
5V
DC
電 源
と の
接 続
セ
ル フ パ ワ ー
用 の
5V
DC
電 源
と の
接 続
Item RRY-16CX-USB RRY-16C-PE RRY-16C(PCI)H
Max. rating capacity 2A 125V(AC), 2A 30V(DC) (load resister)
None
Max. permitted
voltage
125V (Max.) *1, *2
125V(AC), 30V(DC)
Current
consumption (Max.)
5VDC 600mA
3.3VDC 1100mA
5VDC 550mA
Bus specification
USB Specification 2.0/1.1
standard
PCI Express Base
Specification Rev. 1.0a x1
PCI(32bit, 33MHz, Universal
key shapes supported)
Physical
dimensions (mm)
180(L) x 140(D) x 34(H)
(No protrusions)
121.69(L) x 110.18(H)
121.69(L) x 105.68 (H)
Weight 400g
(Not including the USB cable,
attachment)
120g
*1 Please exceed neither max. permitted voltage nor max. rating capacity of the use relay
when using it by the voltage that exceeds 30VDC. Doing so can cause a malfunction.
*2 The potential difference between channels must not exceed 125V in the maximum.
Doing so can cause a malfunction.
Output Signal Connection
Connection with 5VDC Power Supply for
Self-power
Vi+ Power supply (5V)
Vi- Power supply (GND)
FG Frame ground
Difference from RRY-16C-PE and
RRY-16C(PCI)H
PLUG-IN Electronic GmbH • Am Sonnenlicht 5 • 82239 Alling • Tel.: +49 (0) 8141 3697-0 • [email protected] • www.plug-in.de