![Contec RP-COM(FIT)H User Manual Download Page 43](http://html1.mh-extra.com/html/contec/rp-com-fit-h/rp-com-fit-h_user-manual_2655958043.webp)
8. Appendix
38
RP-COM(FIT)H,
RP-COM(FIT)H-AF
Table 8.2. Installation Environment Conditions (Environment Specifications)
Parameter Requirement
description
Operating temperature
0 - 50
°
C
Storage temperature
-10 - 60
°
C
Humidity
10 - 90
%
RH (No condensation)
Floating dust particles
Not extreme
Corrosive gases
None
Line-noise *1
AC line/±2kV, Signal line/±1kV
(IEC1000-4-4Level 3, EN61000-4-4Level 3)
Line-Noise resistance
Static electricity resistance Contact discharge/±4kV
(IEC1000-4-2Level 2, EN61000-4-2Level 2)
Atmospheric discharge/±8kV
(IEC1000-4-2Level 3, EN61000-4-2Level 3)
Vibration resistance Sweep resistance
10 - 57Hz/semi-amplitude 0.15mm, 57 - 150Hz/2.0G
40minutes each in X, Y, and Z directions
(JIS C0040-compliant, IEC68-2-6-compliant)
Impact resistance
15G, half-sine shock for 11ms in X, Y, and Z directions
(JIS C0041-compliant, IEC68-2-27-compliant)
Grounding
Class D grounding (previous class 3 grounding)
*1 : When using POA201-10-2 for RP-COM(FIT)H, when using POA200-20-2 for RP-COM(FIT)H-AF
Table 8.3. Software Specifications
Item Specification
Protocols
IP (RFC 791), ICMP (RFC 792), UDP (RFC 768), ARP (RFC 826),
SNMP (RFC 1157), MIB II (RFC 1213)
Summary of Contents for RP-COM(FIT)H
Page 13: ...1 Before Using the Product 8 RP COM FIT H RP COM FIT H AF ...
Page 23: ...3 Explanation in Mode of Operation 18 RP COM FIT H RP COM FIT H AF ...
Page 33: ...4 Installation and Connection 28 RP COM FIT H RP COM FIT H AF ...
Page 35: ...5 Setup 30 RP COM FIT H RP COM FIT H AF ...
Page 39: ...6 SNMP Agent Functions 34 RP COM FIT H RP COM FIT H AF ...
Page 41: ...7 Troubleshooting 36 RP COM FIT H RP COM FIT H AF ...