3. External Connection
DIO-96D-LPE
39
Connecting I/O Signals
The I/O circuits of interface blocks of the DIO-96D-LPE are illustrated in Figure 3.4. Signals are
LVTTL-levels and positive logic.
I/O Circuit
GND
GND
INPUT/OUTPUT
74LV245A
33
Ω
External circuit
Board
Figure 3.4. I/O Circuit
CAUTION
-
Take care not to short the outputs to digital ground as this may cause a fault.
-
If connecting pull-up resistors to the outputs, use a resistor of approximately 10k
Ω
and pull-up to the
3.3V power supply.
-
The inputs support input of TTL level (5VDC) signals.