3 Function Description
CPS-PWD-30AW24-01
5
3.
Function Description
The Range of the Input Voltage
If the input voltage varies, it might excess the accuracy of the voltage regulator.
Contact us for details.
This unit is capable of coping with instant input voltage dip. (Derating is required.)
- Output range up to : 30W
- Input : AC50V or DC70V
- Duty : 1s/30s
* Never operate for more than a second or longer. The unit can de damaged.
-Usable between AC85 and AC264V.
The approval of safety standards is “100AC - 240VAC (50/60Hz)” for the rated input
voltage range.
If input value doesn’t fall within above range, a unit may not operate in accordance with
specifi cations and/or start hunting or operate protection circuit or fail.
If you need to apply a square waveform input voltage, which iscommonly used in UPS and
inverters, please contact us.
Inrush Currents
This unit contains rush current suppression circuit.
If you are to use a switch, make sure it withstands inrush currents.
As a power thermistor is used for inrush current suppression, be sure the unit is cool enough
when restarting input soon after turning on the power.
Output Voltage Adjustment Range
To increase an output voltage, turn a built-in potentiometer clockwise.
To decrease the output voltage, turn it counterclockwise.