Contec CPS-MG341G-ADSC1-930 Reference Manual Download Page 9

  Introduction 

 

CPS-MG341G-ADSC1-930 Reference Manual (Hardware) 

  9 

 

4.

 

Interface Within 

This product is a M2M controller with the following interfaces. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

With the CONPROSYS series, data collected from various types of facilities can be managed centrally. 

 

LAN

SD Card

Slot

USB

Digital Input

Digital Output

Analog Input

Current

Analog Output

Current

Counter

RS-422A/485

RS-232C

3GSIM

(Standard SIM)

CAN

Analog Input

Voltage

Analog Output

Voltage

Interface within             /

  :

Non-interface within

Summary of Contents for CPS-MG341G-ADSC1-930

Page 1: ...M Gateway for PLC Multi Function 3G OPC UA CPS MG341G ADSC1 930 Introduction 5 Safety Precautions 14 Product Nomenclature and Function 23 Setup 40 Installation 49 Appendix 75 Optional Products 87 Cust...

Page 2: ...g and the storage in EU signatory 22 Product Nomenclature and Function 23 1 Nomenclature of Product Components 24 2 Description of Product Components 26 1 Power Connector 26 2 Antenna Connector 26 3 S...

Page 3: ...2 LAN 59 3 RS 422A 485 60 4 RS 232C 65 5 Analog Input 67 6 Digital Input Counter Input 69 7 Digital Output 72 Appendix 75 1 Specifications 76 1 Specifications 76 2 Power Requirements 80 2 Physical Di...

Page 4: ...4 Table of Contents Index 91...

Page 5: ...5 Introduction This section provides necessary information of the product such as the outline bundled items and manuals before actual use...

Page 6: ...urpose Contents How to get CONPROSYS Cloud Data Service 2 CDS2 Manual Read this to understand the outline of the CONPROSYS Cloud Data Service 2 This describes the outline and specification of the CONP...

Page 7: ...the product visit our website to check the firmware version and update to the latest one if necessary Updating firmware to the latest version will resolve troubles and stabilize the operation Download...

Page 8: ...and SCADA software that support OPC UA clients from various makers The product is the data collector M2M Gateway for PLC that supports respective PLCs as well as various Modbus devices For equipment...

Page 9: ...interfaces With the CONPROSYS series data collected from various types of facilities can be managed centrally LAN SD Card Slot USB Digital Input Digital Output Analog Input Current Analog Output Curre...

Page 10: ...ing in the temperature between 20 and 60 C It can be installed in the various environments Compact design Compact design 188 0 W x 78 0 D x 30 5 H features flexibility in installation Capable of adapt...

Page 11: ...an operation check The product has LED for an operation check which helps you visually confirm the communication status of each interface No electrolytic capacitor No electrolytic capacitor is used T...

Page 12: ...hrough a Web browser Web Task Script By combining icons such as arithmetic operations conditional branching data outputting you can set up the executions or its processes like drawing them in the flow...

Page 13: ...ber Label 1 3 pin Connector 3 Power Analog 5 pin Connector 1 RS 422A 485 10 pin Connector 1 Digital Antenna 1 EU Declaration of Conformity 1 This product is verified in conformity with our recommended...

Page 14: ...14 Safety Precautions Understand the following definitions and precautions to use the product safely Never fail to read them before using the product...

Page 15: ...or or moderate injury or in property damage Informations de s curit Ce document contient des informations relatives la s curit sous utilisation des symboles suivant afin d viter tout accident risquant...

Page 16: ...y Do not use the product in such applications If using the product in applications where safety is critical such as in railways automotive or disaster prevention or security systems please contact you...

Page 17: ...les immediately and contact your retailer To connect with peripherals use a grounded shielded cable To clean the product wipe it gently with a soft cloth dampened with either water or mild detergent D...

Page 18: ...ANGER Ne pas utiliser le produit dans des endroits expos s des gaz inflammables ou corrosifs L exposition peut provoquer une explosion un choc lectrique ou une d faillance Ne pas mettre le dispositif...

Page 19: ...Pour une utilisation dans un tel environnement installer par exemple un panneau de contr le l preuve de la poussi re viter d utiliser le produit dans des endroits susceptibles aux chocs ou aux vibrat...

Page 20: ...up de foudre s lectionner le bon dispositif de protection contre les surtensions pour tous les voies d acc s ligne de transport lectrique r seau local RS 232C RS 422A 485 AI DIO module d entr e sortie...

Page 21: ...ntial area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense FCC WARNING Changes or modifications not expressly approved by...

Page 22: ...accumulators at their end of life should be disposed separately from the household waste If a chemical symbol is printed beneath the symbol mark shown above it indicates that the battery or accumulato...

Page 23: ...23 Product Nomenclature and Function This section describes product component names and their functions pin assignment of each connector...

Page 24: ...rd to store data 7 USB Port This is a TYPE A USB port 8 RS 232C Serial Port This is a RS 232C serial port male 9 LED Indicator This indicates status of the product 10 Reset Switch This resets the prod...

Page 25: ...enclature and Function CPS MG341G ADSC1 930 Reference Manual Hardware 25 No Name Function 16 RS 422A 485 Connector This is a connector for RS 422A 485 communication Use the 5 pin connector included in...

Page 26: ...3P 14 1000AH or equivalent The type of connectors in the package differs depending on the period of manufacturing To check the supplied connector type refer to Appendix Connector Check Pin Assignment...

Page 27: ...ndard SIM size 25x15 mm 4 3G LED The LED displays the intensity of the signal reception The higher RSSI indicates the more intensified signal reception Color and Description LED color Display RSSI Gre...

Page 28: ...of USB interface of TYPE A Pin Assignment Pin No Signal Name 1 USB_VCC 2 DATA 3 DATA 4 USB_GND CAUTION If you use the USB device with bus power the ambient temperature should be 55 C or lower ATTENTIO...

Page 29: ...baud rate is 115 200bp Max Pin Assignment Pin No Signal Name Direction Description 1 CD Input Carrier detection 2 RD Input Reception data 3 TD Output Transmission data 4 DTR Output Data terminal ready...

Page 30: ...is no data transmission by RS 422A 485 RX COM A Yellow Flashing It flashes upon receiving data by the RS 422A 485 OFF It indicates there is no data reception by RS 422A 485 TX COM B Yellow Flashing It...

Page 31: ...ternal connection state of TX and RX Open Full Duplex SW1 1 ON RTS Communication Mode Half Duplex OFF RTS Communication Mode Full Duplex 2 2 OFF 3 OFF This indicates it is set in the default setting 2...

Page 32: ...ta Output 3 RX Reception data Input 4 N C This pin is left unconnected 5 N C This pin is left unconnected 6 RX Reception data Input 7 N C This pin is left unconnected 8 N C This pin is left unconnecte...

Page 33: ...dware 33 CAUTION If a large amount of data or high speed response is requested an external switching HUB will be required ATTENTION En pr sence d un volume lev de donn es ou lorsqu une r ponse haute v...

Page 34: ...signals from the other devices 3 DI1 This indicates the input signals of channel 1 It connects the output signals from the other devices 4 DI2 CNT0 This indicates digital input signals of channel 2 an...

Page 35: ...nector included in the package to connect to external power Connector type DEGSON 15EDGK 3 5 03P 14 1000AH or equivalent The type of connectors in the package differs depending on the period of manufa...

Page 36: ...to connect to external power Connector type DEGSON 15EDGK 3 5 05P 14 1000AH or equivalent The type of connectors in the package differs depending on the period of manufacturing To check the supplied c...

Page 37: ...cognition of input signals from being affected by noise or chattering Operation Principle The digital filter checks the input signal level during the sampling time of 1 4 cycles of digital filter sett...

Page 38: ...0Bh 256 sec 1 01h 0 25 sec 12 0Ch 512 sec 2 02h 0 5 sec 13 0Dh 1 024msec 3 03h 1 sec 14 0Eh 2 048msec 4 04h 2 sec 15 0Fh 4 096msec 5 05h 4 sec 16 10h 8 192msec 6 06h 8 sec 17 11h 16 384msec 7 07h 16...

Page 39: ...effectively if the filter time is set s etting data 1 10 shorter than the opto coupler response time ATTENTION Le filtre num rique s applique tous les canaux d entr e il ne peut pas se limiter uniquem...

Page 40: ...40 Setup This section describes how to set switches and an antenna that are necessary to operate the product...

Page 41: ...etup Set the terminators on or off in accordance with the device which you are communicating with The DIP switch SW2 sets the terminator The terminators on the product are 100 resistors If you intend...

Page 42: ...x OFF RTS Communication Mode Full Duplex 2 System Reservation Always OFF 3 System Reservation Always OFF 4 System Reservation Always OFF 5 System Reservation Always OFF 6 System Reservation Always OFF...

Page 43: ...plex OFF RTS Communication Mode Full Duplex 4 ON System Reservation Always OFF OFF System Reservation Always OFF SW1 1 ON System Reservation Always OFF OFF System Reservation Always OFF 2 System Reser...

Page 44: ...ence Manual Hardware 44 2 Set Antenna Set the supplied antenna to the antenna connector Turn the antenna in the direction of the arrow shown to fasten CAUTION Double check whether the antenna has been...

Page 45: ...over Card cover is attached to the product upon shipping 2 Slide the card cover to remove it 3 With the chipped edge of the SD card is in the position shown below insert the card all the way into the...

Page 46: ...Setup CPS MG341G ADSC1 930 Reference Manual Hardware 46 5 Fasten with a screw Reverse the procedure described in the Insert SD card to remove the card...

Page 47: ...sten the screw of the cover Card cover is attached to the product upon shipping 2 Slide the card cover to remove it 3 With the chipped edge of the SIM card is in the position shown below insert the ca...

Page 48: ...DSC1 930 Reference Manual Hardware 48 4 Insert the catch of the card cover into the opening shown in the figure below 5 Fasten with a screw Reverse the procedure described in the Insert SIM card to re...

Page 49: ...49 Installation This section describes how to mount the product on a DIN rail or on the wall and to connect to an external device with a cable...

Page 50: ...l the product in the orientations shown below 0 C Other orientations may cause problems such as malfunctions due to inadequate heat dissipation DIN rail Mounting Wall Mounting Operating ambient temper...

Page 51: ...is within the specified range an operational malfunction may occur if there is other device generating high heat the radiation will influence the product to increase its temperature Do not install th...

Page 52: ...cro tre la temp rature et mener une d faillance ou d autres probl mes Lors de l utilisation du produit dans un environnement temp rature lev e la dur e de vie du produit sera r duite Pour contrebalanc...

Page 53: ...m a DIN Rail How to Mount 1 Pull down the hooks to unlock If the hooks are stuck use a slotted screwdriver to unlock 2 1 Hang the product on the upper part of the DIN rail 2 Press it to the lower side...

Page 54: ...ow to Remove 1 Pull down the hooks to unlock If the hooks are stuck use a slotted screwdriver to unlock 2 1 With the hooks unlocked pull the lower part of the product toward you 2 By lifting the produ...

Page 55: ...he product CAUTION Tightening torque should be carefully controlled according to the wall on which you are installing to Installing onto the wall may not satisfy the UL standard certification ATTENTIO...

Page 56: ...cable and insert it to the opening 2 After the insertion secure the stripped part by turning screws with a slotted driver to prevent it from disconnecting CAUTION Removing the connector plug by graspi...

Page 57: ...ur retirer la fiche vous risquez de briser le fil Saisissez toujours le connecteur pour le retirer Le couple de serrage pour le connecteur fourni est indiqu ci dessous DEGSON 0 19 N m PHOENIX CONTACT...

Page 58: ...his product is designed to operate at least with 15watt power supply In addition the power supply must fulfill the following requirements Rising time for up to 12 voltage 2 milliseconds up to 30 milli...

Page 59: ...connecteur fourni est indiqu ci dessous DEGSON 0 19 N m PHOENIX CONTACT PTR MESSTECHNIK 0 25 N m D nudez environ 7 mm plus ou moins 0 5 mm de la section gain e du c ble pour le raccorder au connecteu...

Page 60: ...57 600 900 19 200 1 200 9 600 The cable lengths in the table are not guaranteed for the communication speed The table below lists the maximum communication distances of the terminator resistor value...

Page 61: ...bps Error 300 0 00 600 0 00 900 0 00 1 200 0 00 2 400 0 00 4 800 0 00 9 600 0 16 14 400 0 16 19 200 0 16 28 800 0 16 38 400 0 16 57 600 0 16 115 200 0 16 Half Duplex Half duplex needs two or more set...

Page 62: ...the external device Full Duplex Full duplex needs three or more sets of twisted pair Two sets are for a signal line other free line s is are for the signal ground SG Connect TX and TX RX and RX to mak...

Page 63: ...e used as the signal ground SG CAUTION Tightening torque of the supplied connector is 0 19N m Strip off approximately 7mm plus or minus 0 5mm of the covered part of a cable to connect with the connect...

Page 64: ...N m PHOENIX CONTACT PTR MESSTECHNIK 0 25 N m D nudez environ 7 mm plus ou moins 0 5 mm de la section gain e du c ble pour le raccorder au connecteur Si les c bles blind s sont mal raccord s la mise l...

Page 65: ...cial treatment of the signal lines in the connector is required ensure that this is done in accordance with the specifications Refer to RS 232C Serial Port in the page 29 for details of the RS 232C se...

Page 66: ...he baud rate that can be set with the product Error rate differs depending on the set baud rate Baud Rate bps Error 300 0 00 600 0 00 900 0 00 1 200 0 00 2 400 0 00 4 800 0 00 9 600 0 16 14 400 0 16 1...

Page 67: ...und of this product with ground of signal source by braided shield CAUTION Removing the connector plug by grasping the cable can break the wire Always grasp the connector to remove it Tightening torqu...

Page 68: ...MESSTECHNIK 0 25 N m D nudez environ 7 mm plus ou moins 0 5 mm de la section gain e du c ble pour le raccorder au connecteur En l absence d un raccordement de masse analogique les donn es de conversio...

Page 69: ...er to Appendix Connector Check Input equivalent circuit of digital counter input interface unit is shown in Figures below DI connects to a device which can be current driven such as switch or transist...

Page 70: ...ting Switch Connecting the Input to the source type output Connecting to an external device A_COM Input pin B_COM This Product Sink type output External Power Supply This Product Minus common A_COM B_...

Page 71: ...lt in power supply Corresponded to current sink output Connecting Switch Connecting the Input to the sink type output Connecting the product to an external device B_COM This Product External device 12...

Page 72: ...eriod of manufacturing To check the supplied connector type refer to Appendix Connector Check Digital Output Circuit DO connects to the device controlled by the current drive such as relay controlling...

Page 73: ...can break the wire Always grasp the connector to remove it Tightening torque of the supplied connector is described below DEGSON 0 19 N m PHOENIX CONTACT PTR MESSTECHNIK 0 25 N m Strip off approximat...

Page 74: ...urs le connecteur pour le retirer Le couple de serrage pour le connecteur fourni est indiqu ci dessous DEGSON 0 19 N m PHOENIX CONTACT PTR MESSTECHNIK 0 25 N m D nudez environ 7 mm plus ou moins 0 5 m...

Page 75: ...75 Appendix This section lists the specifications and the physical dimensions of the product and the details of model name...

Page 76: ...bit 1 1 5 2stopbit Parity check Even Odd Non parity Connector 2 piece 3 5mm pitch 5 pin terminal TX TX RX RX SG Applicable wire AWG28 16 LED Transmission Yellow Reception Yellow Switch DIP Switch Full...

Page 77: ...an be done by software The number of channels 4 It is possible to allocate 2channels to counter input Count Type Up count Max count FFFFFFH binary data Counter response speed 1kHz Max Duty 50 Max Inte...

Page 78: ...voltage range 10 8 30VDC Power consumption 12V 0 8A Max 24V 0 4A Max Connector 2 piece 3 5mm pitch 3 pin terminal V V FG Applicable wire AWG24 16 Surge protection element V V V FG Interactive TVS diod...

Page 79: ...ance Line noise AC Line 2kV 10 Signal Line 1kV IEC61000 4 4 Level 3 EN61000 4 4 Level 3 Static electricity resistance Touch 4kV IEC61000 4 2 Level 2 EN61000 4 2 Level 2 Air 8kV IEC61000 4 2 Level 3 EN...

Page 80: ...me When you use with the CPS PWD 15AW12 01 by CONTEC instantaneous voltage drop allowed time is 20 milliseconds or less ATTENTION Si les fluctuations de la tension d alimentation sont au del des carac...

Page 81: ...Antenna Steerable Range 4 3 5 3 8 mm 188 78 66 4 170 154 55 30 5 20 4 26 LAN A 12 24VDC COM A RESET SW1 SD LAN B Isolated R S 422A 485 AI1 AI0 DI CNT SHUT DO0 DO1 COM B USB RS 232C TERM Half Full MOD...

Page 82: ...Appendix CPS MG341G ADSC1 930 Reference Manual Hardware 82 4 Standard SIM size 25mm 15mm...

Page 83: ...y Integrated Type Model 2 CPU 3 ARM Cortex A8 3 Memory 4 512M Byte 4 Version 1 The 1st Model 5 Function G 3G Model 6 Interface A Analog I O D Digital I O S Serial RS 232C RS 422A 485 C Counter 7 Numbe...

Page 84: ...een 0 25 N m Connector type Socket MC1 5 3 G 3 5 Green Connector type Plug DEGSON 15EDGK 3 5 03P 14 1000AH Green 0 19 N m Connector type Socket 15EDGRC THR 3 5 03P 13 Black 5pin Connector Connector ty...

Page 85: ...N m Type de connecteur broche MC1 5 3 G 3 5 Vert Type de connecteur enfichable DEGSON 15EDGK 3 5 03P 14 1000AH Vert 0 19 N m Type de connecteur broche 15EDGRC THR 3 5 03P 13 Noir Connecteur 5 broches...

Page 86: ...sing of the product follow the instruction below and remove the battery 1 Remove the five screws from bottom of the product to remove the cover See the figure below 2 Remove the cover 3 Cut the two ho...

Page 87: ...87 Optional Products This section lists optional items that can be used along with the product...

Page 88: ...oduct Name Model type Description DIN rail fitting power supply CPS PWD 15AW12 01 Fitting power supply 15W Input 100 240VDC Output 12VDC 1 3A SD Card SD 4GB A SD card 4GB Magnet CPS MAG01 4 Magnet Fou...

Page 89: ...89 Customer Support and Inquiry CONTEC provides the following support services for you to use CONTEC products more efficiently and comfortably...

Page 90: ...rs the useful information including product manuals that can be downloaded through the CONTEC website Download https www contec com download You can download updated driver software firmware and diffe...

Page 91: ...91 Index...

Page 92: ...30 Reference Manual Hardware 92 Revision History MONTH YEAR Summary of Changes July 2017 The First Edition April 2018 Changed the layout of the manual September 2018 Additional information was listed...

Page 93: ...5 Japan https www contec com No part of this document may be copied or reproduced in any form by any means without prior written consent of CONTEC CO LTD CPS MG341G ADSC1 930 Reference Manual Hardware...

Reviews: