4. Functions
CNT-3204MT-LPE
47
Sampling mode
In the sampling mode, the board samples the count value periodically to load it into memory on the PC
according to the specified internal or external clock.
For the sampling mode, sampling operation conditions must be set as well as counter operation
conditions. For details about sampling, see “Sampling function” described later in this chapter. The
counter start can be synchronized with the sampling start.
Figure 4.10. Timing chart (Counter-asynchronous sampling mode)
Figure 4.11. Timing chart (Counter- synchronous sampling mode)
Pulse input signal
Sampling clock
Count value
0
1
2
3
4
5
6
7
8
8
Nothing
Sampling value
4
Counter start
Counter stop
Sampling start
Sampling stop
4
Nothing
2
Pulse input signal
Sampling clock
Count value
0
0
1
2
3
4
5
6
7
7
Nothing
Sampling value
0
3
Sampling start
Sampling stop
7
Summary of Contents for CNT-3204MT-LPE
Page 7: ...vi CNT 3204MT LPE ...
Page 15: ...1 Before Using the Product 8 CNT 3204MT LPE ...
Page 29: ...2 Setup 22 CNT 3204MT LPE 3 Click on the End button to finish condition setting Click on End ...
Page 45: ...3 External Connection 38 CNT 3204MT LPE ...
Page 69: ...4 Functions 62 CNT 3204MT LPE ...
Page 73: ...5 About Software 66 CNT 3204MT LPE ...
Page 78: ......