Contec AIO-160802LI-PE Quick Start Manual Download Page 3

 

Ver.1.05 

  AIO-160802LI-PE   

  3   

 

List of Options 

 

Shield Cable with 50-Pin Mini-Ribbon Connectors  
at either Ends 

    

:PCB50PS-0.5P (0.5m) 

 

    

:PCB50PS-1.5P (1.5m) 

Shield Cable with 50-Pin Mini-Ribbon Connector  
at one End 

    

:PCA50PS-0.5P (0.5m) 

 

  

:PCA50PS-1.5P (1.5m) 

Screw Terminal Unit (M3 x 50P) 

    

:EPD-50A *1*2 

Buffer Amplifier Box for Analog Input Boards   
(8ch type) 

    

:ATBA-8L *1*3 

Buffer Amplifier Box for Analog Input Boards   
(16ch type) 

    

:ATBA-16L *1*3 

BNC Terminal Unit   
(for analog input 8ch) 

    

:ATP-8L *1*4 

 
*1  PCB50PS-0.5P or PCB50PS-1.5P optional cable is required separately. 
*2  “Spring-up” type terminal is used to prevent terminal screws from falling off. 
*3  An external power supply is necessary (optional AC adaptor POA200-20 prepared.) 
*4  Capable of using the analog input of up to 8ch, and analog output of up to 2ch. 

 

* Check the CONTEC’s Web site for more information on these options. 

 

 

 

How to connect the connectors 

 

Connector shape 
To connect an external device to this board, plug the cable from the 
device into the interface connector (CN1) shown below.   

 

 

Connector Pin Assignment 
Pin Assignments of AIO-160802LI-PE Interface Connector (CN1) 

Non Connect 

N.C. 

50 

 

25  AO 00 

Analog Output 00 

Analog Ground ( for AO ) 

AGND 

49 

24  AGND 

Analog Ground ( for AO ) 

Non Connect 

N.C. 

48 

23  AO 01 

Analog Output 01 

Analog Ground ( for AO ) 

AGND 

47 

22  AGND 

Analog Ground ( for AO ) 

Analog Input 04 

AI 04 

46 

21  AI 00 

Analog Input 00 

Non Connect 

N.C. 

45 

20  N.C. 

Non Connect 

Analog Input 05 

AI 05 

44 

19  AI 01 

Analog Input 01 

Non Connect 

N.C. 

43 

18  N.C. 

Non Connect 

Analog Ground ( for AI ) 

AGND 

42 

17  AGND 

Analog Ground ( for AI ) 

Analog Ground ( for AI ) 

AGND 

41 

16  AGND 

Analog Ground ( for AI ) 

Analog Input 06 

AI 06 

40 

15  AI 02 

Analog Input 02 

Non Connect 

N.C. 

39 

14  N.C. 

Non Connect 

Analog Input 07 

AI 07 

38 

13  AI 03 

Analog Input 03 

Non Connect 

N.C. 

37 

12  N.C. 

Non Connect 

AO External Start Trigger AO START  36 

11  AI START  AI External Start Trigger 

AO External Stop Trigger AO STOP 

35 

10  AI STOP  AI External Stop Trigger 

AO External Sampling Clock AO EXCLK  34 

9  AI EXCLK  AI External Sampling Clock 

Digital Ground 

DGND 

33 

8  DGND 

Digital Ground 

Digital Output 00  

DO 00 

32 

7  DI 00 

Digital Input 00 

Digital Output 01 

DO 01 

31 

6  DI 01 

Digital Input 01 

Digital Output 02 

DO 02 

30 

5  DI 02 

Digital Input 02 

Digital Output 03 

DO 03 

29 

4  DI 03 

Digital Input 03 

Digital Ground 

DGND 

28 

3  DGND 

Digital Ground 

Counter UP Clock Input 

CNT 

27 

2  CNT 

Counter Gate Control Input 

Reserved 

Reserved 

26 

1  CNT OUT  Counter Output 

 

 

Analog Input00 - Analog 
Input07 

Analog input signal.  The numbers correspond to channel numbers. 

Analog Output00 - Analog 
Output01 

Analog output signal. The numbers correspond to channel numbers. 

Analog Ground 

Common analog ground for analog I/O signals. 

AI External Start Trigger 
Input 

External trigger input for starting analog input sampling. 

AI External Stop Trigger 
Input 

External trigger input for stopping analog input sampling. 

AI External Sampling Clock 
Input 

External sampling clock input for analog input. 

AO External Start Trigger 
Input 

External trigger input for starting analog output sampling. 

AO External Stop Trigger 
Input 

External trigger input for stopping analog output sampling. 

AO External Sampling Clock 
Input 

External sampling clock input for analog output. 

Digital Input00 - Digital 
Input03 

Digital input signal. 

Digital Output00 - Digital 
Output03 

Digital output signal. 

Counter Gate Control Input  Gate control input signal for counter. 

Counter Up Clock Input 

Count-up clock input signal for counter. 

Counter Output 

Counter output signal. 

Digital Ground 

Common digital ground for digital I/O signals, external trigger inputs, external sampling 
clock inputs, and counter I/O signals. 

Reserved 

Reserved pin. 

N.C. 

No connection to this pin. 

 

CAUTION 

Do not connect any of the outputs and power outputs to the analog or digital ground. 
Neither connect outputs to each other.  Doing either can result in a fault. 

If analog and digital ground are shorted together, noise on the digital signals may affect the 
analog signals.   Accordingly, analog and digital ground should be separated. 

Leave "Reserved" pins unconnected.  Connecting these pins may cause a fault in the board. 

 

 

Analog Input Signal Connection 

Single-ended Input 
The following figure shows an example of flat cable connection. 
Connect separate signal and ground wires for each analog input 
channel on CN1. 

Single-ended Input Connection (Flat Cable) 

 

The following figure shows an example of shield cable connection. Use 
shielded cable if the distance between the signal source and board is 
long or if you want to provide better protection from noise.   For each 
analog input channel on CN1, connect the core wire to the signal line 
and connect the shielding to ground. 

Single-ended Input Connection (Shield Cable) 

 

*1  The number of channels depends on each board.  The AIO-160802LI-PE has eight channels. 
 

CAUTION 

If the signal source contains over 1MHz signals, the signal may effect the cross-talk noise 
between channels. 

If the board and the signal source receive noise or the distance between the board and the 
signal source is too long, data may not be input properly. 

An input analog signal should not exceed the maximum input voltage (relate to the board 
analog ground).    If it exceeds the maximum voltage, the board may be damaged. 

Connect all the unused analog input channels to analog ground. 

The signal connected to an input pin may fluctuate after switching of the multiplexer.  If this 
occurs, shorten the cable between the signal source and the analog input pin or insert a high-
speed amplifier as a buffer between the two to reduce the fluctuation. 

Analog ground of CN1 is isolated from the ground in the PC. 

 

 

 

Analog Output Signal Connection 

This section shows how to connect the analog output signal by using a 
flat cable or a shielded cable. 
The following figure shows an example of flat cable connection. 
Connect the signal source and ground to the CN1 analog output. 

Analog Output Connection (Flat Cable) 

 

 

- Connector used

50-pin mini-ribbon connector

10250-52A2JL[mfd.by 3M]

-

connector

10150-6000EL[mfd. by 3M]

Compatible

Interface connector (CN1)

CN1

50

25

26

1

Analog Input 0..15*1

Analog Ground

BOARD

CN1

Cable

Signal Source

Analog Ground

Shield cable

Analog Input 0..15*1

BOARD

CN1

Signal Source

Analog Output 0..3*2

Analog Ground

BOARD

CN1

Cable

Target

 

PLUG-IN Electronic GmbH  •  Am Sonnenlicht 5  •  82239 Alling  •  Tel.: +49 (0) 8141 3697-0  •  [email protected]  •  www.plug-in.de

Reviews: