Table 2.2. Installation Environment Requirements
Model PT-955LS-ACx000
PT-955LS-ACx121
PT-955LS-ACx421
Operating temperature *5
0 - 50
C (0 - 45ºC when using
1000BASE-T)
0 - 45
C (0 - 40ºC when using
1000BASE-T)
0 - 50
C (0 - 45ºC when using
1000BASE-T)
Storage temperature
-10 - 60
C
Operating humidity
10 - 90%RH (No condensation)
Maximum wet bulb
temperature
39
C (No condensation)
Floating dust particles
Not to be excessive
Corrosive gas
None
Line noise
AC line /
2kV,
Signal line/
1kV (IEC61000-4-4 Level 3, EN61000-4-4 Level 3)
Noise
resistance
Static
electricity
resistance
Contact discharge /
4kV (IEC61000-4-2 Level 2, EN61000-4-2 Level 2),
Atmospheric discharge /
8kV (IEC61000-4-2 Level 3, EN61000-4-2 Level 3)
(Nonoperating)
10 - 57Hz / semi-amplitude
0.15 mm
57 - 150Hz / 2.0G,
40 min. each in x, y, and z
directions
10 - 57Hz / semi-amplitude
0.15 mm
57 - 150Hz / 2.0G,
40 min. each in x, y, and z
directions
(Operating)
10 - 57Hz / 0.5G
25 min. each in x, y, and z
directions
10 - 57Hz / semi-amplitude
0.15 mm
57 - 150Hz / 2.0G,
40 min. each in x, y, and z
directions
Vibration
resistance
Sweep
resistance
JIS C60028-2-6-compliant, IEC68-2-6-compliant
Impact resistance
10G, half-sine shock for 11 ms and 3 times in
x, y, and z directions
(JIS C60068-2-27-compliant, IEC68-2-27-compliant)
Grounding
Class D grounding, SG-FG / continuity
*5 : For more details on this, please refer to chapter 3, “Installation Requirements”.