Specifications
RF Characteristics
Number of simultaneous channels
4
Internal Frequency Accuracy
2 ppm. (Typical 1ppm)
Frequency Range
400 MHz
–
2700 MHz
150 MHz
–
400 MHz (Optional)
2700 MHz
–
3700 MHz (Optional)
Frequency Step
100 KHz
Modulation
CW (Continuous Wave); single carrier
Minimum output power
-10 dBm
Maximum output power
15 dBm @ 150 MHz to 1800 MHz
10 dBm @ 1800 MHz to 2700 MHz
5 dBm @ 2700 MHz to 3500 MHz
2 dBm @ 3500 MHz to 3700 MHz
Power Accuracy
±1 dB (typ. ±0.5 dB)
Off Transmit Power
-100 dBm
Non-Harmonic spurious
<-40dBc @ 10dBm output power
RF output
50-ohm SMA Female
Power supply
Power Consumption
<14 Watts
DC Input
12 VDC, 2 A power adapter
Battery
7.2 V, 2.2 A Li-ion chargeable battery
Battery Operation time
105 minutes (Field exchangeable battery)
Physical
External Dimensions
L179 x W80 x H43mm
Antenna interface
SMA Female
Weight
< 700gm incl. battery
Operating Temp
-10 to +40 C