Consort UHA05 Installation & Control Manual Download Page 4

 

 

Consort Equipment Products Limited 

Thornton Industrial Estate, Milford Haven, Pembrokeshire, SA73 2RT 

Tel: 01646 692172   Fax: 01646 695195 

Email: [email protected]   Web: www.consortepl.com 

Operation hours: Mon to Thu 8.30am to 4.30pm | Fri 8.30am to 3.30pm 

48000035  Iss 11 

F

ROST

 F

IGHTER

 S

ETTING

 

Your appliance can be used in various situ-
ations to protect against frost. 
Examples are; in the attic, protecting water 
tanks and pipes. 
To set  the unit to function in  these environ-
ments,  turn  the  thermostat  knob  anti-
clockwise  to  the  ‘frost  fight’  position,  as 
shown in figure 2..  
The thermostat is now set at approximately 
5

0

C.  This means that when the air tempera-

ture  around  the  unit  drops  below  approxi-
mately  5

0

C  the  unit  will  switch  itself  on.    It 

will  continue  to  operate  until  the  air  tem-
perature  surrounding  the  unit  rises  above 
5

0

C  and  then  will  switch  itself  off,  coming 

back on again when the temperature starts 
to drop. 

T

HERMAL

 O

PERATED

 C

UT

-

OUT

 

The appliance is fitted with a thermally op-
erated cut-out (TOC). This is a safety de-
vice, which switches the heater off if, for 
any reason, the appliance overheats. The 
TOC can only be re-set after the appliance 
has cooled down.  In order to re-set the 
TOC, proceed as follows: 

 

Switch off appliance and leave for 
approximately 5 minutes. 

 

Switch appliance back on and the 
TOC will re-set. 

 

Ensure that the appliance is function-
ing correctly.  If the ES Control oper-
ates again, the appliance should be 
checked by a competent Electrician. 

 

Controls  

Model UHA05 has a heat rating of 0.45 kW.  
Model  UHA10S,  which  is  fan  assisted,  has  a 
heat  output  of  1.0  kW  and  incorporates  a 
switch which controls the element.  With the 
switch  in  the  position  shown  in  Diagram  D, 
both element and fan are engaged. 
With the switch in the position shown in Dia-
gram E the fan only will run. 
Both  these  switch  settings  are  subject  to 
thermostat control. 

T

HERMOSTAT

 

The appliance is fitted with a thermostat.  To 
set  the  thermostat  to  the  require  tempera-
ture turn the control knob fully clockwise, to 
the position shown in figure 1 . When desired 
room temperature is reached, turn the knob 
slowly anti-clockwise and when the thermo-
stat  clicks  off  leave  the  control  at  this  set-
ting. hereafter the appliance will control the 
heat  output  automatically.  A  ‘Frost  Fighter’ 
position  is  marked  on  the  unit.    This  is  the 
lowest setting on the thermostat and repre-
sents approximately 5

0

C. 

 

C

USTOMER

 H

ELPLINE

 

 

Should you need any advice on the use of your new Consort product, please contact 

our Helpline: 

Figure 1 

Figure 2 

Reviews: