Consort PLSTi050ERF Installation & Control Manual Download Page 6

 

 

Ensuring you don’t waste energy on heating the outside 

world, the heater is equipped with optional open / 
closed window detection. The heater recognises sudden 
drops in temperature when a window or a door is 
opened and turns the heating off to save energy. When 
the window is closed, the heater will automatically 
detect a temperature rise,  and switch itself back on. 
Once enabled in the setup menu, the open window 
detection is fully automatic and does not require any 
human intervention to be activated.  

 

Setting-up Open Window Detection 

The system has been factory set to default time and 
temperature values. If necessary, all values can be 
adjusted. When the heating is on, open window 
detection sensor will automatically switch the heater off 
when it detects a fall in temperature of 2°C in less than 10 
minutes (this temperature can be changed in menu 7 
and time in menu 6). If a temperature rise of 2°C in less 
than 30 seconds is detected, the heater will switch itself 
back on (this temperature can be changed in menu 9 
and time in menu 8). 

15. Open Window Detection 

1. 

Press and hold TEMP and MODE together for 5 
seconds. 

2. 

The display will enter the setup menu. 

3. 

Use TEMP and MODE to change a value. 

4. 

Use  TIME to scroll between the settings. 

 
01 - temperature calibration 
The temperature reading has been factory calibrated 
but if for any reason it needs adjusting (better accuracy 
required, to suit different position in the room etc.), the 
reading can be recalibrated in 0.5 degrees steps. 

 
02 - change between degrees Celsius or Fahrenheit 
 
03 - set minimum temperature

 

 

       (3.5 deg = frost protection) 

When this is set, the heater will operate in any mode 
should the room temperature fall below the set 
temperature.

 

 
04 - set maximum temperature 

When this is set, the maximum temperature in any mode 
cannot exceed the limit. 

 
05 - open window detection  0 = off, 1 = on 
 
06 - 600 - open window detection time 600 seconds 
 
07 - 2 - temperature drop of 2

°

C in the detection time 

 
08 - 30 - closed window detection time of 30 seconds 
 
09 - 2 -

 

temperature rise of 2

°

C in the detection time 

17. Setup menu 

16. Intelligent Fan Control 

The intelligent fan control incorporates one of the latest 
low energy consumption BLDC motors. This allows the 
heater to operate quietly, whilst still providing the best 
possible levels of comfort.  

 

Depending on which heat mode is activated, it will 

calculate the best possible airflow temperature and will 
adjust the fan speed accordingly. If the heater is   
running in fan mode only (heat switched off), then the 
fan will operate at a fixed speed.  

 

NOTE: When turning the heater on, there is a 30 seconds 
delay until the fan starts running to allow the heater to 
warm up. After the heater is switched OFF the fan will 
continue running for a short period of time. When 
changing the heat mode or fan speed mode, the fan will 
respond accordingly after a small time delay. 

 

18. Status light on the heater

 

   Light colour                                   Heater status 

STAND-BY  No heat output 

Reduced heat output 

Full power heat output 

14. Keys locking 

Press and hold TIME and TEMP together for 5 seconds. The  

display will show        symbol.  Repeat the step to unlock.     

66001080 Iss 01 

19. Connection to MRX1 

This PLSTi

 RF range is compatible with the MRX multi-zone controller. To pair the PLSTi-RF with the MRX1, set the MRX1 to 

pairing mode (see section 10 of MRX User Instructions).  

Pairing a RF Timer. 

On the electronic RF timer, press and hold TIME and PROG for 10 seconds. The timer will show a unique code, the RF 
Icon will then flash to show the pairing signal is being sent. Once this has stopped you should see a new 4 digit code 
showing pairing was successful. The MRX display shows CONNECTED. Tap BACK and the zone is now connected.   To 
exit pairing mode on the timer press and hold the time button.  

Summary of Contents for PLSTi050ERF

Page 1: ...able electricity supply or subject to misuse neglect damage or modified or repaired by any person not authorised by us This guarantee is offered to you as an extra benefit and does not affect your leg...

Page 2: ...nce should be checked by a qualified person The heater carries a Do Not Cover label to warn the user that if the appliance is covered there is a risk of overheating Warning Do NOT site the appliance i...

Page 3: ...Installation 3 MILLIMETRES WATTS A B C D E PLSTi050ERF PLSTi075ERF 500 750 506 430 210 148 PLSTi100ERF 1000 640 430 364 138 PLSTi150ERF 1500 892 430 616 138 66001080 Iss 01 3 See Page 2 for Mounting...

Page 4: ...n use the PROG button to increase the timer in 15 minute increments After it reaches 4 hours and PROG is pressed again the timer resets to 15 minutes To amend the set temperature when in BOOST mode si...

Page 5: ...me and a temperature for each program 13 Heat symbol on the display Every time there is a demand for heat the display will show the heat icon Reduced heat output when the room temperature is close to...

Page 6: ...rature in any mode cannot exceed the limit 05 open window detection 0 off 1 on 06 600 open window detection time 600 seconds 07 2 temperature drop of 2 C in the detection time 08 30 closed window dete...

Page 7: ...leaning Always disconnect the heater from the mains before cleaning The heater should not require any mainte nance but it is strongly advised that it is kept clean An occasional wipe over with a soft...