Consort PLSTi050ERF Installation & Control Manual Download Page 1

Installation & Control Guide for Slimline Low Surface  

Temperature Wall Mounted Fan Heater 

with Intelligent Fan Control & Electronic 7-Day Timer

 

All electrical appliances produced for the Company are guaranteed for one year against 
faulty  material  or  workmanship.    This  applies  only  if  the  appliance  has  been  used  for 
purposes in accordance with the instructions provided and has not been connected to an 
unsuitable electricity supply, or subject to misuse, neglect, damage or modified or repaired 
by any person not authorised by us. This guarantee is offered to you as an extra benefit and 
does not affect your legal rights. 
 
The  correct  electricity  supply  voltage  is  shown  on  the  rating  label  attached  to  the 
appliance. 
 
Reasonable  care  has  been  taken  to  ensure  that  this  guide  is  accurate  at  the  time  of 
printing. In the interest of progress the Company reserve the right to vary specifications from 
time to time without notice.

 

Q

UALITY

 S

PACE

 H

EATERS

 

Models 

 

 

 

            

 

        

PLSTi050ERF, PLSTi075ERF, PLSTi100ERF, PLSTi150ERF

 

66001080 Iss 01 

Summary of Contents for PLSTi050ERF

Page 1: ...able electricity supply or subject to misuse neglect damage or modified or repaired by any person not authorised by us This guarantee is offered to you as an extra benefit and does not affect your leg...

Page 2: ...nce should be checked by a qualified person The heater carries a Do Not Cover label to warn the user that if the appliance is covered there is a risk of overheating Warning Do NOT site the appliance i...

Page 3: ...Installation 3 MILLIMETRES WATTS A B C D E PLSTi050ERF PLSTi075ERF 500 750 506 430 210 148 PLSTi100ERF 1000 640 430 364 138 PLSTi150ERF 1500 892 430 616 138 66001080 Iss 01 3 See Page 2 for Mounting...

Page 4: ...n use the PROG button to increase the timer in 15 minute increments After it reaches 4 hours and PROG is pressed again the timer resets to 15 minutes To amend the set temperature when in BOOST mode si...

Page 5: ...me and a temperature for each program 13 Heat symbol on the display Every time there is a demand for heat the display will show the heat icon Reduced heat output when the room temperature is close to...

Page 6: ...rature in any mode cannot exceed the limit 05 open window detection 0 off 1 on 06 600 open window detection time 600 seconds 07 2 temperature drop of 2 C in the detection time 08 30 closed window dete...

Page 7: ...leaning Always disconnect the heater from the mains before cleaning The heater should not require any mainte nance but it is strongly advised that it is kept clean An occasional wipe over with a soft...