Consair CAMU D2 Instruction Manual Download Page 4

Consair CAMU D2 is an effective and energy efficient source 
extractor, which is easy to use and move at the construction 

site and which is designed for the professional extraction of 
dust produced by the mixing of dry matter, such as concrete, 

mortar, and plaster.

The  Consair  CAMU  D2  source  extractor  can  collect  over 
99% of the dust produced in the mixing area. The effective 

and automatically adjusted suction air flow guarantees that 
the  CAMU  D2  source  extractor  operates  at  full  capacity 

throughout the entire lifecycle of the filters.

With  the  aid  of  the  advanced  pressure  measurement  sys-
tem,  CAMU  D2  is  able  to  detect  if  either  the  main  filter  or 
pre-filters are clogged.
 The indicator lights in the control panel indicate if the filters 
need to be replaced.

The  CAMU  D2  pre-filter  equipped  with  a  dust-collection 
container developed by Consair Oy is able to collect 750–
1,500 g of dust produced by the mixing of dry matter. This 
amount of dust is produced when approximately 5,000 kg of 
dry matter is mixed.

Thanks  to  the  pre-filter  equipped  with  a  dust-collection 
container,  there  is  no  need  to  handle  dust-producing  filter 
materials in connection with filter replacement. Thus, the fil-
ters can be changed without releasing any dust into the air.

The source extractor has been designed to be primarily used 
with 20-litre mixing containers. When the height of the de-
vice is increased by, e.g., lifting it onto a pallet, it is also suit-
able for use with large mixing containers.

CAMU  D2  protects  both  the  worker  and  working  environ-
ment from dust and prevents mixing splatter from spreading 
outside the workstation.

Since the device can be used as both a personal and joint 
workstation,  it  is  suitable  for  use  in  both  construction  and 
renovation sites.

This instruction manual describes the operation of the Con-

sair CAMU D2 source extractor. In this manual, it is also re-

ferred  to  as  the  ‘device’  or  ‘machine’.  Read  the  instruction 

manual before implementation and familiarise yourself par-
ticularly well with the safety regulations.

The instruction manual is also available at www.consair.eu. 

If  you  wish  to  obtain  more  information  about  the  Consair 
CAMU  D2  source  extractor,  contact  the  manufacturer,  re-
tailer, or leasing company.

1

2

Intended purpose

The Consair CAMU D2 source extractor has been designed 

for indoor use, and it may only be used for the processing 

of  dry  matter,  such  as  dry-mix  concrete  and  mortar.  The 

device  may  not  be  used  for  the  processing  of  materials 

containing  explosive,  flammable,  or  harmful  substances, 
such as asbestos.

If the CAMU D2 source extractor is, however, used for oth-

er purposes or handled in a manner other than the one de-

scribed  in  this  instruction  manual,  Consair  Oy  will  not  as-
sume  responsibility  for  the  consequences  of  the  incorrect 

use.

3

Important information

!

2

Introduction

Consair CAMU D2

5

Warranty

The Consair CAMU D2 source extractor has a 12-month war-
ranty that covers material and manufacturing defects.

No  modification  or  repair  work  may  be  carried  out  on  the 
structure  of  the  machine  without  the  manufacturer’s  con-
sent. The warranty does not cover defects that are caused 
by  careless  or  incorrect  use,  negligence,  or  normal  wear 
and tear. In the case of a complaint, the machine must be 
returned to the manufacturer for possible repair or replace-
ment.

The device is delivered with a pre-filter (1 pcs), main filter (1 
pcs), and air-guiding/splashguard doors (2 pcs).

The filters and door panels are consumable parts. New filters 
and door panels can be ordered from either the manufactur-
er, retailer, or leasing company.

4

Delivery content

Summary of Contents for CAMU D2

Page 1: ...4 2019 Consair CAMU D2 FI K ytt ohje Original SV Bruksanvisning EN Instructions DE Gebrauchsanweisung Source extractor for dust control in dry mix blending...

Page 2: ...Manufacturer Consair Oy Lapinlahdenkatu 16 FI 00180 Helsinki Finland info consair fi consair eu...

Page 3: ...0 Contents 1 Consair CAMU D2 Transportation at the construction site Transportation in the cargo space of a vehicle Mechanical lifting Cleaning of the device Cleaning of the engine bay Replacement of...

Page 4: ...is suitable for use in both construction and renovation sites This instruction manual describes the operation of the Con sair CAMU D2 source extractor In this manual it is also re ferred to as the de...

Page 5: ...cator light in the control panel indicates that a filter has become clogged The device may not be used without filters Do not attempt to clean the filters as cleaning may damage the filter material Cl...

Page 6: ...s running and the suction is on the indicator lights and the work light are on When the device is in the stand by mode the indicator lights flash simultaneously and the work light is off 8 4 Work ligh...

Page 7: ...ter enclosure frame 4 Pre filter enclosure 5 Suction air 6 Air guiding splashguard door 7 Magnetic hinge 8 Locking screw of the air guiding doors 9 LED work light 10 W 10 Differential filter pressure...

Page 8: ...be first passed through the washer and then the door panels and the tubular frame The heads of the pins are to be bent around the tubular frame 10 Maintenance 6 Consair CAMU D2 9 1 Filter types and ca...

Page 9: ...7 Consair CAMU D2 Figure 4 Pre filter replacement 2 3 4 1 2 Figure 5 Pre filter replacement Figure 6 Replacement of the panels in the air guiding doors 6 A 6 B 1 3...

Page 10: ...a quick release cargo strap that goes around the device 11 3 Mechanical lifting The device has not been designed to be lifted mechanically and it does not contain a lifting lug intended for mechanica...

Page 11: ...t of the device This reduces the device s capacity to transfer air which means that less dust can be collected with the filters The wiring harness or control unit of the device may have become damaged...

Page 12: ...4 35 EC complies with the relevant provisions of the EMC Directive 2014 30 EC on electromagnetic compatibility On behalf of Consair Oy signed by Place time Manufacturer authorised representative Signa...