I. Summary 

 

In order to make the device a standard serial interface and an external device or to ensure 

communication between intelligent instruments, must be standard serial interface conversion. 
WM-210 interface converter can be a standard RS232C serial interface data: send and receive 
RXD TXD signals into TTL / COMS compatible voltage levels. TTL level is 0-5V, no 
external power supply, the internal use of the unique "RS232 charge pump" circuit drive, do 
not need to initialize the RS232 serial port can be obtained by power; interior with zero 
latency, the unique I / O circuit automatically control data flow direction, and without any 
handshaking signals (RTS, DTR), thus ensuring the RS232 full-duplex mode without 
changing a program written in TTL mode can run well, ensure that it meets the existing 
operating software and interface hardware. 

 

II. Technical parameters 

 

Interface: conforming to EIA/TIA RS-232 and 

TTL/COMS specification

   

Connector: DB9 connectors for both ends. 

Transmission mode: asynchrony, full duplex, full transparent. 

Transmission rate: 300bps-115.2kbps. 

Measurements: 63mm*34mm*18mm 

Working environments: -40 degrees to 85 degrees

relative humidity 5% to 95%. 

Transmission media: twisted -pair or STP 

Transmission distance: 5m   

 

III. Connector and signal 

RS-232C Pin distribution 

 

 

 

 

 

 

 