Operating the cooler
A-40
10
Ensure that food or liquids in glass containers are not excessively
refrigerated. Liquids expand when they freeze and can thus destroy
the glass containers.
Connecting to 220 V – 240 V
Check that the voltage specification on the type plate corresponds
to that of the energy supply.
➤
Plug the earthed plug into a properly installed safety plug socket.
➤
Set the thermostat control (
2
2, page 3) to “MAX”.
➤
Wait until the temperature in the cooler has dropped.
➤
Set the thermostat control (
2
2, page 3) to the desired temperature range.
➤
To
switch off
the cooler, set the thermostat control (
2
2, page 3) to “0”
and pull out the plug.
Connecting to 12 V DC
You cannot set the temperature with the thermostat control
during battery operation. The device is simply switched on
and starts cooling.
Disconnect the cooler from the battery when the engine is not
running as otherwise the battery will be completely run down.
➤
Make sure that the cable from the battery to the cooler is protected by
a fuse (max. 15 A).
➤
Select a cable cross section for the cable between the battery and the
socket of the 12 V voltage supply
in accordance with the following table:
➤
Make sure that the thermostat control for 220 V – 240 V operation (
2
2,
page 3) is in the “0” position.
➤
Insert the plug of the connection cable into the 12 V socket
(e.g. cigarette lighter).
The polarity cannot be reversed.
➤
To
switch off
the cooler, pull the plug out of the socket.
Cable length
Cable cross section
Up to 2.5 m
2.5 mm²
2.5 m to 4.0 m
4.0 mm²
A-40.book Seite 10 Donnerstag, 1. Dezember 2005 2:52 14
Summary of Contents for Mobicool A40
Page 2: ...A 40 book Seite 2 Donnerstag 1 Dezember 2005 2 52 14...
Page 4: ...A 40 4 1 3 A 40 book Seite 4 Donnerstag 1 Dezember 2005 2 52 14...
Page 122: ...A 40 book Seite 122 Donnerstag 1 Dezember 2005 2 52 14...
Page 123: ...A 40 book Seite 123 Donnerstag 1 Dezember 2005 2 52 14...
Page 124: ...www mobicool com 4445100122 10 2005 A 40 book Seite 124 Donnerstag 1 Dezember 2005 2 52 14...