Version 04/07

OPERATING INSTRUCTIONS

Flush-mounted
battery transmitter
„FS20 S4UB“

Item no. 62 30 17

Summary of Contents for FS20 S4UB

Page 1: ...Version 04 07 OPERATING INSTRUCTIONS Flush mounted battery transmitter FS20 S4UB Item no 62 30 17 ...

Page 2: ... these operating instructions Please read the operating instructions completely and observe the safety and operation notes before using the product All company names and product names contained herein are trademarks of the respective owners All rights reserved Should you have any further questions please contact our technical advisory service Germany Tel no 49 9604 40 88 80 Fax no 49 9604 40 88 48...

Page 3: ...2 channel operation 18 e Switching between 2 channel and 4 channel operation 18 f Timer function in 2 channel operation 18 8 Integrating the FS20 S4UB into the address system programming 19 a Setting the house code 19 b Setting the addresses 20 1 Programming a single address in 4 channel operation 20 2 Programming a single address in 2 channel operation 21 9 Information on the range 22 10 Battery ...

Page 4: ...rated using any installation buttons To ensure its convenient operation four buttons are already fixed to the circuit board The integrated lithium battery boasts an approximate battery life of up to 10 years For information on how to replace the battery please make sure that you read the relevant section of this user manual Any use other than the one described above may damage the product and can ...

Page 5: ... of icons The icon with a lightning flash in a triangle is used to alert you to potential personal injury hazards such as electric shock The icon with an exclamation mark in a triangle points to important instructions in this user manual that must be observed The hand symbol provides special information and advice on operating the device ...

Page 6: ...not permitted This product is not a toy and should be kept out of the reach of children Children are unable to appreciate the dangers associated with electric devices The product should only be operated in dry indoor areas Do not expose the device to heat cold or direct sunlight In order to prevent short circuits or unintentional transmissions or to stop the battery from prematurely wearing out at...

Page 7: ...he flush mounted battery transmitter FS20 S4UB the following points naturally apply to all batteries and rechargeable batteries Keep batteries rechargeable batteries out of the reach of children Make sure that the polarity is correct when inserting batteries rechargeable batteries Do not leave batteries rechargeable batteries lying around as they could be swallowed by children or pets In such case...

Page 8: ...n 1 Button 3 Button 2 Button 4 black blue red yellow green Do not shorten the button cables or wire end sleeves Lengthening is pos sible using terminal strips or junction box terminals Buttons TA1 to TA4 on the circuit board are connected in parallel with the exter nal buttons Figure 1 ...

Page 9: ...ying conductors are laid in the designated installation box or a socket or a switch needs to be removed in the case of multiple covers for instance then you should take the following necessary measures First switch off the respective electrical circuit by turning and removing the relevant fuse or switching off the circuit breaker Make sure that nobody accidentally switches on the electrical circui...

Page 10: ...you choose you may only wish to install one button for example If fewer than four buttons are installed programming can only be carried out via the buttons TA1 TA2 TA3 and TA4 which are integrated into the device Caution If the FS20 S4UB is installed in a flush mounted socket that also contains voltage carrying cables terminal strips junction box terminals then certain precautions need to be taken...

Page 11: ... different house codes are possible This makes it extremely unlikely that your neighbour will use the same house code assuming that you do not use simple house codes The second part of the code is the so called address Every address is a four digit number made up of the following 16 numbers 11 12 13 14 21 22 23 24 31 32 33 34 41 42 43 44 Example Address 11 22 This means that there are a total of 2...

Page 12: ...t transmitter address types have been set you can program the receiver consecutively to these different addresses The individual address types have the following function Single addresses Each receiver should be set to a single address so that it can be controlled separately Function group addresses Several receivers are defined as a functional unit by being assigned to a function group address If...

Page 13: ...on when leaving a house for example The figure below illustrates a possible configuration of different FS20 components in a house 1111 1144 4411 4444 1122 1144 4444 1131 1144 4444 1211 1212 4411 4444 1311 4411 4444 1411 4411 4444 1412 4444 A B C D Global master address 4444 Local master address e g 1144 House code e g 1234 1234 Function group 44xx e g 4411 ceiling lamps Figure 2 Example of an addr...

Page 14: ...re possible 11 12 13 14 21 22 23 24 31 32 33 34 41 42 43 This value must not be set to 44 In order to be able to separately control each receiver you need to program each one to a single address In addition to the address group that is already selected room A 11 room B 12 room C 13 room D 14 a subaddress is also needed The following 15 subaddresses are possible for each address group 11 12 13 14 2...

Page 15: ...this example The ceiling lamps in all the rooms are also combined in a function group 4411 in the example address group 44 subaddress 11 and can therefore be jointly controlled For a function group 44 must always be used as the address group The subaddress can be set to 11 12 13 14 21 22 23 24 31 32 33 34 41 42 or 43 Example 4411 address group 44 subaddress 11 ...

Page 16: ...ion Switching Pressing a button briefly for fewer than 0 4 seconds sends a TOGGLE command changing between two switch states Dimming If a button is pressed for longer than 0 4 seconds the corresponding dim command DIM UP DIM DOWN is sent until the button is released When the DIM UP DIM DOWN command is issued a lamp is dimmed up to the maximum and then dimmed down to the minimum etc The dim directi...

Page 17: ...the same addresses and only need to be changed if required for example if you are using an extensive FS20 wireless control system with numerous receivers transmitters Please also see the example in section 6 c Timer function in 4 channel operation Buttons TA1 TA2 or TA3 TA4 constitute a button combination for programming a receiver s timer function Proceed as follows to program the device Press an...

Page 18: ...our individual switching channels Press buttons TA2 and TA3 simultaneously for at least 5 seconds Switching to 2 channel operation two switching channels with two buttons each Press buttons TA1 and TA4 simultaneously for at least 5 seconds Please note Different operating and programming instructions apply when a double number of channels has been set f Timer function in 2 channel operation In orde...

Page 19: ...UB within each house code a Setting the house code Once the operating voltage has been switched on the FS20 S4UB flush mounted battery transmitter selects a random house code As the transmitter is supplied with a preinstalled lithium battery its random house code is also preset at the factory If required this house code can be changed as follows Keep the TA1 and TA3 buttons on the flush mounted ba...

Page 20: ...the single address address group subaddress for a single button proceed as follows Press and hold the button to be programmed Then press the other button of the button combination and keep both buttons pressed simultaneously for a minimum of five seconds Then release both buttons Use the TA1 TA2 TA3 and TA4 buttons to enter a two digit address group and a two digit subaddress Example 1431 address ...

Page 21: ...pective button combination simultaneously for at least five seconds channel 1 Buttons TA1 and TA2 Channel 2 Buttons TA3 and TA4 Then release both buttons again Use the TA1 TA2 TA3 and TA4 buttons to enter a two digit address group and a two digit subaddress Example 1431 address group 14 subaddress 31 The programming mode ends automatically once you have entered the fourth digit ...

Page 22: ...ange Other causes of reduced ranges All types of high frequency interference Any buildings or vegetation Conductive metal parts that are located near the devices or within or near their transmission path for example radiators metallised insulation glass windows reinforced concrete ceilings etc Influence on the radiation pattern of antennas due to the distance from the transmitter or receiver to co...

Page 23: ...h the costs of getting the battery replaced It may be necessary to replace the battery if you experience an increasing number of reception problems on all channels the causes of which are not listed in section 9 Check whether anything has changed For example the receiver may be installed at a different location metal objects may have been positioned near the transmitter receiver a computer may hav...

Page 24: ...mitter from the installation box Carefully cut open the transparent shrink film Never short circuit contacts on the battery or circuit board Do not damage any components or the circuit board itself CAUTION A short circuit of the lithium battery even if it is almost empty can cause an explosion Remove the battery from its holder Make sure you use a non conductive tool to do this A short circuit of ...

Page 25: ...xplosion or a fire Cut the shrink film along the contours of the device so that its buttons are uncovered and can be used Once again make sure that you do not cause a short circuit and that you do not damage the components or the circuit board Install the FS20 S4UB flush mounted battery transmitter in its previous installation location and attach the installation button If you previously switched ...

Page 26: ...hort circuit of the lithium battery can cause an explosion Avoid the following adverse ambient conditions at the installation location or during transport Moisture or excessive air humidity Extreme cold or heat Dust or flammable gases vapours or solvents Strong vibrations Strong magnetic fields such as those found near machines or loudspeakers Please let a professional workshop carry out the neces...

Page 27: ...hibited The identifiers for the respective heavy metals are Cd cadmium Hg mercury Pb lead identifier is on the battery recharge able battery for example under the rubbish bin icons on the left You can return your used batteries rechargeable batteries free of charge to any authorised disposal station in your area in our stores or in any other store where batteries rechargeable batteries are sold By...

Page 28: ... years Dimensions 57 x 15mm diameter x height 15 Declaration of conformity DOC We Conrad Electronic Klaus Conrad Straße 1 D 92240 Hirschau Germany hereby de clare that this product complies with the fundamental requirements and other relevant regulations of directive 1999 5 EG You can find the declaration of conformity for this product at www conrad com ...

Page 29: ...29 ...

Page 30: ...30 ...

Page 31: ...31 ...

Page 32: ...is permitted in whole or part e g photocopy microfilmingorstorageinelectronicdataprocessingequipment without the express written consent of the publisher The operating instructions reflect the current technical specifications at time of print We reserve the right to change the technical or physical specifications Copyright 2006 by Conrad Electronic SE Printed in Germany 100 recycling paper Bleache...