Alarm sensitivity setting:
Conforms to EN 50291-1:2018
30PPM Without alarm before 120 minutes
50PPM: Alarm between 60 to 90 minutes
100PPM: Alarm between 10 to 40 minutes
300PPM: Alarm within 3 minutes
NOTE: Refer to “3. What to do if the alarm sounds” when you hear
the sounds of the CO alarm warning.
3.4 CO alarm warning silence
During the device under CO alarm mode, pressing the TEST/SILENCE
button, it will be paused alarm sound of the device about 10 minutes.
-
tes the device is running into the CO alarm silence mode.
NOTE: The audible alarm signal will reactivate about 10 minutes
from the time the TEST/SILENCE button is operated where the con-
centration of CO surrounding the
alarm remains at 50 PPM or greater.
NOTE: The audible alarm signal cannot to silence if the alarm at
concentration above 200 PPM.
NOTE: The alarm silencing activation to once throughout a CO
alarm period.
WARNING! Before enable feature of CO alarm warning silen-
-
rous levels of carbon monoxide and the dwelling should be
ventilated.
3.5 Low battery voltage warning
If the device chirps once every 40 seconds, with FAULT indicator (yel-
-
ways displays „ „.
NOTE: When the low battery voltage warning is occur, the device
has capable of producing a CO alarm signal for at least 4 min or 30
days of low battery voltage warning signal operation.
NOTE: The device will not protect against the risk of carbon mono-
xide poisoning when the battery has drained.
3.6 Low battery voltage warning silence
When the device is under the low battery warning, pressing the
TEST/SILENCE button, it will come into a low battery voltage warning
silence status for about 9 hours, meanwhile it will appear „ „ on
NOTE: The silence feature of low battery voltage warning is tempo-
battery as soon as possible.
3.7 Fault warning
If the device chirps twice every 40 seconds with FAULT indicator (yel-
-
tion. The LCD displays „ Err „, that means your CO alarm have no de-
tecting function and no respond CO.
NOTE: Maybe the sensor is missing, replace the device immediate-
ly. Please contact us to more service.
2. Product overview
2.1 POWER indicator
The POWER indicator (green LED) is used to indicate power status of
2.2 FAULT indicator
The FAULT indicator (yellow LED) is used to indicate fault or warning
status of the CO alarm.
2.3 ALARM indicator
The ALARM indicator (red LED) is used to indicate alarm status of the
CO alarm.
2.4 TEST/SILENCE button
The TEST/SILECNE button is used to test the unit. Press and hold to
enable TEST function.
2.5 Alarm sounder
The alarm sounder is used to send out CO alarm warning and fault
warning information.
2.6 LCD screen
Indicates CO concentration and alarm status.
3. Understanding your CO alarm
3.1 Start up
This is preheated state, 60 seconds later the POWER indicator (green)
The LCD displays all segments 4s and count down. When the
countdown is „0“, the product goes into normal operation.
3.2 Normal operation
LCD alternately displays current CO concentration and temperatu-
re every 40s. CO concentration display range: 0~999PPM. If the CO
concentration is under 20PPM, the LCD will display „0PPM“. If the CO
concentration overruns 999PPM, the LCD will display „999PPM“. Tem-
perature display range:-9~50
℃.
If CO concentration overruns 20PPM,
the function of temperature display will be
disable.
3.3 CO alarm warning
When the device detects a dangerous level of CO, the device will emit
a loud alarm pattern. The alarm signal pattern is 4 beeps followed by
pattern. This cycle repeats as long as a dangerous CO condition exists.