Intended use

The product is designed as a camera able to transfer recorded images via a USB port
to a PC. 

Via the integrated lenses particularly small objects/surfaces can be magnified and
reproduced. 

The power is supplied via a USB port.

This product complies with the applicable National and European requirements. All
names of companies and products are the trademarks of the respective owner. All
rights reserved.

Package Contents

• Camera

• USB cable

• Table stand

• CD with driver/software

• Operating Instructions

Safety Instructions

The warranty will be void in the event of damage caused by failure to
observe these safety instructions! We will not assume any responsi-
bility for consequential damage. 

We do not assume any liability for material damage or personal injury
caused by improper use or non-compliance with the safety instruc-
tions! The warranty will be null and void in such cases.

• The unauthorised conversion and/or modification of the product is inad-

missible because of safety and approval reasons (CE).

• The product should only be used in dry indoor areas, it must not get damp

or wet!

• The product is not a toy and should be kept out of the reach of children. 

• Attention, LED light: 

Do not look directly into the LED light!

Do not look into the beam directly or with optical instruments!

• Do not leave packing materials unattended. They may become danger-

ous playthings for children.

• Handle the product with care, it can be damaged by impacts, blows, or

accidental drops, even from a low height.

Driver/Software Installation

• Start up your operating system. Place the CD included in delivery in the correspon-

ding drive of your computer. 

• Now the software should automatically start and you can install the software. If the

CD does not autostart you have to start the installation program on the CD manually
(main directory of the CD, e.g. using „autorun.exe“ or the like).

Follow the program’s instructions.

Observe possible information from the manufacturer on the CD.

• Connect the USB connector to a free USB2.0 port on your computer, using the USB

cable supplied when the software asks you to. Windows recognises the new hard-
ware and completes the driver installation.

• Start the software.

Use

• Move the front side of the camera as close as possible to the desired object (e. g.

place the front side on a daily newspaper). 

• Via the big adjustment wheel you can set a sharp picture; using the small adjust-

ment wheel on the side the brightness of the integrated white LEDs can be altered.

Do not overwind the adjustment wheel. Turn the adjustment wheel slowly
so that you can focus the picture exactly. Depending on the distance to the
examined object there might be two positions where the lenses can be
focused (with different zoom levels).

With reflective surfaces or objects the LED light can cause too bright pic-
tures or reflections; reduce the LED’s brightness.

O P E R A T I N G   I N S T R U C T I O N S

www.conrad.com

• Rotate the camera, if necessary, until the picture is aligned in accordance with your

needs.

Make sure no objects touch the lens as they might damage it. Do not touch
the optics (lens will get dirty).

• With the provided table stand the microscope camera can be fixed in a certain posi-

tion.

• A slidable plastic plate (with a magnet at the bottom) can be attached to the table

stand. Two metal clamps can be clipped to the plastic plate, e.g. to fixate a slide.

• Instead of the metal clamps the provided rotary table can be put on, which also dis-

poses of a magnet to be easily put on/removed/rotated. Using the rotary table you
can watch small objects with the microscope camera from different directions.

• The button on top of the microscope camera is used to control the photo capture fea-

ture of the software.

Handling

Never use the product immediately after it has been taken from a cold room
to a warm one. The condensation that forms might destroy the product.

Allow the device to reach room temperature before switching it on. This
may take several hours. 

The housing may not be opened! Any maintenance or repair work must
only be carried out by authorised personnel.

Avoid the following unfavourable ambient conditions at the installation loca-
tion and during transportation:

- Damp or excess air humidity

- Extreme cold or heat

- Dust or flammable gases, fumes or solvents

- Strong vibrations

- Strong magnetic fields such as those found close to machinery or loud-

speakers

When setting up/operating the product, ensure that the cables are not bent,
overwound or squeezed.

Cleaning

Occasionally check the optics of the microscope camera and clean off dust and dirt.
Use an appropriate lens cleaning system e. g. a clean, soft brush. Do not press on the
optics/mechanics of the camera too strongly since it might get damaged. Furthermore,
you might cause scratch marks on the lens.

Disposal

Please dispose of the product, when it is no longer of use, according to the
current statutory requirements.

Technical Data

Sensor ..................................CMOS, 1600 x 1200 Pixel
USB Connection....................USB2.0
Operating voltage ..................5V= (via USB interface)
Lighting..................................4 white LEDs
Magnification ........................approx. 65x / 250x, depending on the size of the 

monitor used

Dimensions (LxWxH) ............approx. 104.5 x 30.5 x 30mm

These operating instructions are a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240
Hirschau (www.conrad.com). 

All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or
the capture in electronic data processing systems require the prior written approval by the editor.
Reprinting, also in part, is prohibited. 

These operating instructions represent the technical status at the time of printing. Changes in 
technology and equipment reserved. 

© Copyright 2010 by Conrad Electronic SE. 