8. Internal Jumper Settings
This system has jumpers on the PCB in the device. Their function is explained in the following:
The exit delay duration cannot be determined. The exit delay is set to 60 seconds ex works.
MISC.
FUNCTIONS
RINGBACK
ON OFF
“MISC. FUNCTIONS”
Determines whether a confirmation is to be output through the acoustic signalling
device output (terminal clamp 5) when the system is activated or deactivated.
Position “ON”
The relay of terminal clamp 5 is activated
twice briefly
, when the system is
activated
. The relay of terminal clamp 5 is activated o
nce briefly
, when the system
is
deactivated
.
Position “OFF”
The relay of terminal clamp 5 is not activated.
15
60 90
30
ENTRY DELAY
(SECONDS)
“ENTRY DELAY (Seconds)”
This jumper determines the duration of the entry delay. The entry delay is activated
when a sensor/detector in alarm zones 1 or 5 triggers when the system is activated.
The following values can be set: 15 seconds, 30 seconds, 60 seconds, 90 seconds.
15
3
5
ALARM
DURATION
(MINUTES)
“ALARM DURATION (Minutes)”
This jumper determines the alarm time duration for terminal clamp 5.
The following values can be set: 3 minutes, 5 minutes, 15 minutes, and permanent
alarm until the system is deactivated.
Observe the applicable statutory and municipal provisions!
The longest acoustic alarm duration permitted in Germany is 3 minutes. There may,
however, be different provisions on this time in certain municipalities and towns.