Conrad Electronic Eurochron 1760612 Operating Instructions Manual Download Page 3

•  The (rechargeable) batteries should be removed from the device if it is not used 

for a long period of time to avoid damage through leaking. Leaking or damaged 

(rechargeable) batteries may cause acid burns if they come into contact with 

your skin. Always use suitable protective gloves when handling damaged 

(rechargeable) batteries.

•  (Rechargeable) batteries must be kept out of the reach of children. Do not leave 

(rechargeable) batteries lying around, as there is a risk that children or pets may 

swallow them.

•  All (rechargeable) batteries should be replaced at the same time. Mixing old and 

new (rechargeable) batteries in the device can lead to (rechargeable) battery 

leakage and device damage.

•  (Rechargeable) batteries must not be dismantled, short-circuited or thrown into 

open  flames.  Never  recharge  non-rechargeable  batteries.  This  may  cause  an 

explosion!

Operating elements

1

4

5

6

3

2

1  Transmission status LED

RCC

 button

RESET

 button

4  Hanger

5  Slide switch for channel selection

6  Battery compartment

Positioning the sensor

   Pay attention when drilling and tightening the screws to ensure that no cables or 

concealed pipes are damaged. We recommend that you mount the outdoor sensor 

to the left or right of a window so as to be able to see the transmission status  

LED (1) clearly.

•  Select the installation location, such as a wall facing north, so that the additional sensor is 

not exposed to direct sunlight. Otherwise, there may be distortion of the measurements. 

Direct precipitation onto the additional sensor (rain or snow) should also be avoided. Install 

the additional sensor in an area that is in the shade all day long as direct sunlight and heat 

dissipation from objects will distort temperature measurements.

•  You can mount the additional sensor to a wall with a suitable screw or nail (neither included).
•  The additional sensor can also be set up on a level, stable surface.
•  The installation should ensure a direct line of sight between the weather station and the 

sensor to ensure good wireless reception. Poor wireless reception should be expected when 

the sensor is near to metal-coated insulated glass windows, reinforced concrete, coated 

wallpapers or electronic devices, or when placed in a cellar. Do not use the sensor on 

vehicles or moving objects.

a) Inserting the batteries into the additional sensor

•  Open the battery compartment cover on the battery compartment (6) on the back of the 

additional sensor.

•  Select a channel using the sliding switch for channel selection (5).
•  Insert two AA batteries (not included) with the correct polarity into the battery 

 

compartment (6) (observe plus/+ and minus/-).

•  The additional sensor is now ready to use. Once the batteries have been inserted, the 

additional sensor starts to send wireless signals at intervals of 60 seconds.

•  Replace the battery compartment cover.

  The additional sensor can be operated with rechargeable batteries. However, the 

operating time is reduced by the lower voltage (battery = 1.5 V, rechargeable battery 

= 1.2 V). Rechargeable batteries are very sensitive to changes in temperature, 

resulting in a shorter battery life in cold conditions. We therefore recommend using 

only high-quality lithium batteries instead of rechargeable batteries.

  Replace the (rechargeable) batteries if no or no permanent connection with the 

connected weather station can be established.

  If you have more than one sensor (max. 8), all sensors must be set to a different 

channel.

The weather station automatically searches for the wireless signal of the sensors and connects 

as soon as one is found. The signal strength or the measurement data of the sensor are shown 

on the display of the weather station once a signal is received.

 Operating instructions

Additional sensor for EFS-3110A

Item no. 1760612

Intended use

The additional sensor is used to capture weather data outdoors. The data measured by 

the sensor are wirelessly transmitted to the weather station. The sensor can also receive 

the DCF time signal and transmit it to the connected weather station. It is constructed 

in accordance with degree of protection IPX3. The additional sensor is powered by 2x  

1.5 V batteries. The sensor can be used with weather stations with Conrad item no. 1615871 

and 1760613, the latter of which does not feature a DCF function. For safety and approval 

purposes, do not rebuild and/or modify this product. Using the product for purposes other than 

those described above may damage the product. In addition, improper use can cause hazards 

such as a short circuit or fire. Read the operating instructions carefully and store them in a safe 

place. If you pass the product on to a third party, please hand over these operating instructions 

as well.
This product complies with statutory, national and European regulations. All company and 

product names included herein are trademarks of their respective owners. All rights reserved.

Delivery content

•  Additional sensor
•  Operating instructions

Up-to-date operating instructions  

Download the up-to-date operating instructions at www.conrad.com/downloads or scan the QR 

code shown. Follow the instructions on the website.

Explanation of symbols

  The symbol with the lightning in a triangle indicates that there is a risk to your health, 

e.g. due to an electric shock.

  The symbol with an exclamation mark in a triangle is used to highlight important 

information in these operating instructions. Always read this information carefully.

  The arrow symbol indicates special information and tips on how to use the product.

Safety information

Read the operating instructions and safety information carefully. If you do 

not follow the safety information and information on proper handling in these 

operating instructions, we will assume no liability for any resulting personal 

injury or damage to property. Such cases will invalidate the warranty/

guarantee.

a) General information

•  The product is not a toy. Keep it out of the reach of children and pets.
•  Do not leave packaging material lying around carelessly. It may become a 

dangerous toy for children.

•  Protect the product from extreme temperatures, direct sunlight, strong jolts, 

flammable gases, vapours and solvents.

•  If it is no longer possible to operate the product safely, take it out of operation and 

protect it from any accidental use. Safe operation can no longer be guaranteed 

if the product:

 - is visibly damaged, 
 - is no longer working properly, 
 - has been stored for extended periods in poor ambient conditions or 
 - has been subjected to any serious transport-related stresses.

•  Please handle the product carefully. Jolts, impacts or a fall even from a low height 

may damage the product.

•  Always observe the safety instructions and operating instructions of any other 

devices which are connected to the product.

•  Consult a technician if you are not sure how to use or connect the product, or if 

you have concerns about safety.

• 

Maintenance, modifications and repairs must only be carried out by a technician 

or a specialist repair centre.

•  If you have any questions that are not answered in these operating instructions, 

please contact our technical customer service or other professionals.

•  In schools, educational facilities and hobby or DIY workshops, the product must be 

operated under the supervision of qualified personnel.

•  Do not cover any openings in the sensor housing during operation.

b) (Rechargeable) batteries

•  Correct polarity must be observed while inserting the (rechargeable) batteries.

Summary of Contents for Eurochron 1760612

Page 1: ...b ausschlie lich hochwertige Lithium Batterien zu verwenden und keine Akkus Bedienungsanleitung Zusatzsensor f r EFS 3110A Best Nr 1760612 Bestimmungsgem e Verwendung Der Zusatzsensor dient zum Erfass...

Page 2: ...cken Sie die Taste RESET einmal um den Zusatzsensor nach einer Fehlfunktion auf die Werkseinstellung zur ckzusetzen Pflege und Reinigung Trennen Sie das Produkt vor jeder Reinigung von der Stromverso...

Page 3: ...wn on the display of the weather station once a signal is received Operating instructions Additional sensor for EFS 3110A Item no 1760612 Intended use The additional sensor is used to capture weather...

Page 4: ...ng alcohol or other chemical solutions as these may damage the housing or cause the product to malfunction Use a damp lint free cloth to clean the product Declaration of Conformity DOC Conrad Electron...

Page 5: ...e de fonctionnement lors de faibles temp ratures ambiantes Nous vous recommandons donc d utiliser uniquement des piles au lithium de qualit lev e et non des piles rechargeables Mode d emploi Capteur s...

Page 6: ...capteur suppl mentaire aux param tre d usine apr s un dysfonctionnement Entretien et nettoyage D branchez toujours le produit avant de le nettoyer N utilisez en aucun cas des produits de nettoyage abr...

Page 7: ...n permanente verbinding met het aangesloten weerstation meer tot stand komt Gebruiksaanwijzing Extra sensor voor EFS 3110A Bestelnr 1760612 Doelmatig gebruik De extra sensor is bedoeld voor de registr...

Page 8: ...nderhoud en reiniging Verbreek voor iedere reiniging de verbinding van het product met de stroomvoorziening Gebruik in geen geval agressieve reinigingsmiddelen reinigingsalcohol of andere chemische pr...

Reviews: