FLEXIBLE GAS CONNECTOR INSTRUCTIONS
To prolong the life of your flexible gas connector, it is important that the
following instructions be precisely adhered to.
IMPORTANT: At no time should the inner track be pulled outward from the
original position while the connector is attached.
The connector is provided with hex-shaped fittings on each end. Fitting ‘A’ should be held
firmly with a wrench and not allowed to turn while a second wrench is used to tighten fitting
‘B’. The threaded fasteners, ‘C’, must always be in a horizontal position, pointing to the rear
of the unit. The connector should be in a smooth U-shape with upper and lower portions
being parallel when moved in any direction.
OUTER TRACK
INNER TRACK
“A”
“B”
“B”
“A”
“C”