background image

Small/no burner flame

Regulator failure

Unplug regulator vent hole or
replace regulator.

Plugged orifice hood

Unplug hole or replace orifice.

Plugged burner port

Unplug burner port(s).

Small/no pilot flame

Pilot valve setting

Adjust flame height.

Plugged pilot tip

Unplug pilot ports.

Yellow burner flame

Improper air shutter setting

Increase air shutter setting until
flame is blue.

Enlarged orifice hood

Replace w/correct orifice.

Flame lifts off burner

Improper air shutter setting

Decrease air shutter setting
until flame sits on burner.

Plugged orifice hood

Unplug orifice hole or replace orifice.

Improper level setting

Adjust level w/feet or shims.

Too hot/cold

Improper control setting

Adjust control setting or replace
control.

Improper level setting

Adjust level w/feet or shims.

Too much/little lava rock

Add/remove lava rock to proper
level;

layer only with air

space.

Condition

Probable Cause

Solution

single

The Connerton Company warrants to the original user for a period of one year from date of installation, not
to exceed 18 months from date of shipment by Connerton, that the equipment manufactured is free from
defects in material or workmanship.

Our obligation under this warranty shall be limited to furnishing without charge any part of said product
which, upon examination by The Connerton Company shall prove to be defective. Parts wear is not
considered a defect. The Connerton Company will not be responsible for labor or transportation charges
incidental to the replacement of same.

The Connerton Company assumes no responsibility for failure of the equipment to operate properly due to
improper installation or operation. This warranty applies to all equipment that has been unaltered, properly
installed and maintained in accordance with national and local codes and in accordance with the
installation and operating instructions included with this equipment.

This warranty does not extend to normal maintenance items, including but not limited to, air and gas
adjustments and adjustments to pilot flames. Proper installation, adjustments, and initial checkout is the
responsibility of the dealer, the owner-user or installer and not that of The Connerton Company.

Exceptions to warranty:

1) Lower lava rock broiler grates.

TROUBLESHOOTING GUIDE

Please fill out and refer to the following when contacting the factory:

Model # RLRB-23-

-A Serial#

Gas Type:

Purchase Date:

LIMITED WARRANTY

Summary of Contents for RLRB-A

Page 1: ...e lava rock evenly in one layer ONLY throughout the firebox area leaving air spaces For both types top grates are notched to secure grate to lip of firebox gutter Please note air vent can plug with grease thereby shutting gas supply off Install regulator in a drip free area RLRB A BUDGET SERIES CHAR BROILERS For Your Safety Warning Improper installation adjustment alteration service or maintenance...

Page 2: ...broiler to the gas supply line Under no circumstances should the gas supply line be smaller than the inlet pipe on the broiler A gas shutoff valve must be installed in the gas supply line upstream of the broiler for complete shutdown and service Use pipe sealant on all pipe joints Sealant must be resistant to the action of L P gasses For proper performance the broiler must be level If legs are pro...

Page 3: ...3 00 225 00 Pilot Valve 6 60 100 01 Top Grate 14 00 250 00 Manual Control Valve 7 60 150 00 Burner 15 00 500 00 Chrome Knob 60 200 02 Orifice Hood Propane 00 275 02 Regulator Propane 17 00 175 00 Lava Rock IMPORTANT Lava Rock NOT to be used with Radiants 10 16 00 275 01 Regulator Natural 8 60 200 01 Orifice Hood Natural For part numbers ending in xx specify model size ie 65 400 37 for a RLRB 23 37...

Page 4: ...t manufactured is free from defects in material or workmanship Our obligation under this warranty shall be limited to furnishing without charge any part of said product which upon examination by The Connerton Company shall prove to be defective Parts wear is not considered a defect The Connerton Company will not be responsible for labor or transportation charges incidental to the replacement of sa...

Reviews: