COM Express® Type 7 + GPU Embedded System
Users Guide
www.connecttech.com
Document: CTIM-00020
Revision: 0.01
Page 25 of 30
Date: 2020-09-17
ON-BOARD INDICATOR LEDS
The COM Express Type 7 + GPU Embedded System has 4 Exterior indicator LEDs. Please refer to the
V7G/D7G manual for further description of internal LEDs.
Function Power/ Reset LEDs
Location
Front Panel
Operation
LED
Exterior Designator
Internal Designator
+12V_CTRL Status LED 1
D36
+12V_CPU Status LED 2
D37
+12V_GPU Status LED 3
D38
RESET#
Status LED 4
D1
Note:
System Default Operation for Status LED 1, 2, 3 is ON
Status LED 4 is OFF.
CURRENT CONSUMPTION DETAILS
Below are the maximum ratings of the COM Express Type 7 + GPU Embedded System. Ratings are
specified below with a 12V input voltage to the system.
Theoretical Maximum
Watts
Theoretical absolute maximum total draw of all functionality of the
COM Express Type 7 + GPU Embedded System
525
Below are measurements taken with the COM Express Type 7 + GPU Embedded System running in
various configurations. Some values will change depending on what operation or software is installed.
All measurements were taken in a lab environment with an ambient temperature of 25 degrees Celsius.
System Specifications:
COMe Type 7 module
Conga B7XD/X-D1577, DDR4-2400 ECC 48GB
MXM GPU
PNY P5000
OS
Ubuntu 16.04
Peripherals
USB Keyboard and Optical Mouse
Actual Measurements
Watts
Desktop Idle, Single HDMI Display
24
CPU Stress test 32 threads, Single HDMI Display
92
CPU Stress test 32 threads, GPU CUDA stress test, Single HDMI
Display
221
Note: SFP+ and Ethernet were not active during testing, values may vary depending on use case.