ConLAB ACT-2I Operator'S Manual Download Page 2

 
 
2. 

CONNECTION DIAGRAM 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

ACT-2V             

 

  ACT-2I 

 

 

3.

 

DIMENSIONS 

 
4.  
Specifications 
 
 

ACT-2I 

 
INPUT:    

 

       AC current 

INPUT SPAN: 

       0-1Aac, 0-5Aac (RMS) 

INPUT BURDEN: 

       0.26VA at 5Aac 

 
INRUSH CURRENT: 

        

 

40Aac (RMS) max. for 8 sec/10min 

 

75Aac (RMS) max  for 1 sec/ 10min 

ISOLATION: 

      2.5KV (RMS)/1 minute 

 
ACT-2V 
 
INPUT:    

 

      Voltage input 

INPUT SPAN: 

       0-400Vac (RMS) 

 
INPUT BURDEN: 

        

 

       1.4VA at 250Vac, 0.3VA at 120 Vac 

ISOLATION: 

       2.5KV (RMS)/1 minute 

 
GENERAL SPECIFICATIONS 
 
OUTPUT RANGE: 

4-20mA 

TEST TERMINALS: 

40-200mV represents 4-20mA 

SUPPLY VOLTAGE: 

 

 

           10-32Vdc, reverse polarity protected 

 
SUPPLY AND LOAD VARIATION EFFECT: 
 

                 < ±0.03% of span for full change 

LOOP DRIVE: 

Rmax (

) = (Vsup-10)/0.02 

RESPONSE TIME: 

220msec. (0-98% of span) 

OUTPUT RIPPLE: 

Better than 0.1% of span RMS 

 
 
 
 

 
 
FREQUENCY: 

40- 60 and 400 Hz 

 
ACCURACY (2-100% of input span): 
 

 ±0.1% of span for pure sinusoidal input 

 
FINE ADJUSTABILITY: 
 

Zero: 

±35% of span (minimum)

 

Span: 

±25% of span (minimum)

 

 

 

 

 

CMR: 

 

122 dB typical, 117 dB      

 

                    minimum 

 
TEMPERATURE STABILITY: 

 

 

                         ±0.015% of  span/1

°

 
OPERATING AMBIENT: 

32 to 158

°

F  

 

                                         (0-70

°

C) 

STORAGE TEMPERATURE: 

-13 to 185

°

F  

 

                                        (-25 to +85

°

C) 

HUMIDITY: 

 

 

 

                 5-95% relative humidity,  non-condensing 
 
PROTECTION LEVEL:   

 

 

Box: 

According to IP-50 DIN 40050 

 

Terminals:  According to IP-10 DIN 40050 

 
MOUNTING: 

Standard 35mm DIN rail 

 
WEIGHT:   

0.5lb (0.2Kg) 

 

 

 

 

 

Reviews: