background image

                                                                                                                                                                                  27

Notizen

Summary of Contents for CLEAR 2.0 K 1

Page 1: ...LEAR 2 0 K 1 KERZENFILTER MONTAGE UND BETRIEBSANLEITUNG CARTRIDGE FILTER OPERATING INSTRUCTIONS FILTR Z WYMIENNYM WK ADEM SIATKOWYM INSTRUKCJA MONTA U I EKSPLOATACJI conel de CLEAR WASSER AUFBEREITUNG...

Page 2: ...ELEKTRISCHE GER TE EINRICHTUNGEN 10 5 ANFORDERUNGEN AN DEN EINBAUORT 11 6 EINBAU 12 6 1 EINBAUMASSE 12 6 2 MONTAGE DES EINBAUDREHFLANSCHS 13 6 3 MONTAGE DES KERZENFILTERS 14 7 BETRIEB 15 7 1 FUNKTION...

Page 3: ...eSiebfiltrationgrob undfeink rnigePartikel diegr erodergleichder MaschenweitedesFiltersiebessind Partikel diekleineralsdie verwendeteSiebmaschenweite sind sowie Tr bstoffe und im Wasser gel ste Stoffe...

Page 4: ...Instandsetzung Installation und Instandhaltung darf nur durch vom Hersteller autorisiertes Personal erfolgen das in der Lage ist die in der Einbau und Betriebsanleitung genannten Anweisungen und die...

Page 5: ...ationalen Einheitensystem SI Syst me International d Unit s werden folgende Einheiten und Begriffe verwendet Achtung Dieses Zeichen weist auf einen Punkt hin der f r einen zuverl ssigen Betrieb oder d...

Page 6: ...d Transportsch den da sp tere Reklamationen nicht mehr anerkannt werden k nnen Dieser Kerzenfilter ist f r den Einsatz in kaltem bis max 30 C Trinkwasser Wasser der kommunalen Wasserversorgung entwick...

Page 7: ...IN 1988 ff sowie der DIN EN 1717 Sie sind vom DVGW Deutsche Vereinigung des Gas und Wasserfaches e V Technisch wissenschaftlicher Verein gem den Anforderungen derDIN EN 13443 1 und DIN 19628 f r mecha...

Page 8: ...chtbestimmungsgem er Verwendung und bei Nichtbeachtung der Gefahrensymbole und Sicherheitshinweise F r hieraus resultierende Sch den haftet der Hersteller Lieferer nicht Das Risiko tr gt allein der An...

Page 9: ...Die Nichtbeachtung dieser Betriebsanleitung und deren Sicherheitshinweise kann sowohl eine Gef hr dung f r Personen als auch f r die Umwelt und den Kerzenfilter zur Folge haben 4 4 WASSERDRUCK Der Wa...

Page 10: ...Sind die elektrischen Ger te Einrichtungen an die Stromversorgung angeschlossen kann es au erdem zu einem Kurzschluss kommen F r Personen besteht in diesem Fall die Gefahr eines Stromschlags In der N...

Page 11: ...die Wasserzufuhr bei Installation Wartung Reparatur und Fehlfunktion des Kerzenfilters unterbrochen werden ber schwemmungen und gr ere Wassersch den an Hauseinrichtungen lassen sich so vermeiden Ist...

Page 12: ...bb 4 Einbauma e Einbauma CLEAR 2 0 K CLEAR 2 0 K 1 CLEAR 2 0 K 1 A Einbaul nge mit Verschraubungen 180 195 230 A Einbaul nge ohne Verschraubungen 100 100 110 B Ger tebreite 124 124 124 C H he oberhalb...

Page 13: ...r mechanischen Besch digung bis hin zum Bruch der Rohrleitung oder des Ein baudrehflanschs kommen Daraus k nnen gr ere Wassersch den resultieren Personen die sich in der N he des Kerzenfilters aufhalt...

Page 14: ...rzenfilter montiert wird muss das Gewicht des Kerzenfilters sicher aufneh men k nnen Ansonsten kann es zu einer mechanischen Besch digung bis hin zum Bruch kommen Daraus k nnen gr ere Wassersch den re...

Page 15: ...de Schmutz ist von au en durch die transparente Filterglocke sichtbar Die Blende der Filterglocke dient im geschlossenen Zustand als UV Schutz Anschlie end verl sst das gefilterte Was ser den Kerzenfi...

Page 16: ...chlie end Blende der Filterglocke abnehmen Mit einem Innensechskantschl ssel die vier Zylinderschrauben M6 130 l sen Filterglocke nach unten abziehen und altes Sieb mit Dichtung entfernen Ein neues Si...

Page 17: ...17 Abb 8 Wechsel des Siebeinsatzes I 1 2 3 II 4 III 5 6 IV 7 8 9 10...

Page 18: ...somit zu einem gro en Durchflusswiderstand kommen Bei Neuinstallationen wird erfahrungsgem in der Anfangszeit verst rkt Schmutz abgelagert In diesem Fall muss der Siebeinsatz h ufiger gewechselt wer d...

Page 19: ...or Arbeiten am Kerzenfilter die ber die reine betriebsbedingte Bedienung hin ausgehen muss der Kerzenfilter drucklos gemacht werden Es d rfen nur Original Ersatzteile verwendet werden Eigenm chtige Um...

Page 20: ...zenfilters mit Trinkwasser in Kontakt kommen und an dieses abge geben werden Personen die verschmutztes Wasser aufnehmen sind gesundheitlich gef hrdet Den Kerzenfilter frostfrei lagern Durch Frost kan...

Page 21: ...rtrag sichert am besten eine gute Betriebsfunktion auch ber die Gew hrleistungszeit hi naus Es ist anzustreben dass die regelm igen Wartungsarbeiten und die Versorgung mit Verbrauchsmaterial bzw Versc...

Page 22: ...sst nach Sieb ist verstopft Siebeinsatz wechseln Undichtheiten am Kerzenfilter Installateur oder n chst gelegenen Kundendienst informieren Filterglocke wird tr b Kerzenfilter wurde h heren Tem peratu...

Page 23: ...23 10 ERSATZTEILE Abb 9 Ersatzteile CLEAR 2 0 K 1 9 12 13 14 15 1 3 7 11 8 9 2 10 6 B C...

Page 24: ...ke und Flansch bestehend aus Pos 13 14 1 2080158 1 Zylinderschraube M6 130 4 1650134 2 Deckel 1 3 O Ring 52 3 5 1 6 Abdeckhaube vorne komplett 1 7 Stopfen Manometer komplett 1 8 Grundgeh use 1 9 Profi...

Page 25: ...sserrohrbr chen Leckagen Defekten an der Hauswasserinstallation sowie vor au ergew hnlich hohem Wasser verbrauch Erkennt rinnende Wasserh hne und Armaturen Technische Daten CLEAR 2 0 K CLEAR 2 0 K 1 C...

Page 26: ...CLEAR von CONEL f r Ausk nfte gerne zur Verf gung Deutschland T 49 0 7195 692 0 Frankreich T 33 0 3 88 65 93 94 Wir empfehlen Ihnen dringend einen Wartungsvertrag abzuschlie en damit alle Wasseraufbe...

Page 27: ...27 Notizen...

Page 28: ...DEVICES EQUIPMENT 36 5 REQUIREMENTS FOR THE PLACE OF INSTALLATION 37 6 INSTALLATION 38 6 1 INSTALLATION DIMENSIONS 38 6 2 MOUNTING THE BUILT IN ROTARY FLANGE 39 6 3 MOUNTING THE CARTRIDGE FILTER 40 7...

Page 29: ...creen filtration coarse and fine grained particles larger or equal to the mesh size of the filter screen Particles smaller than the supplied mesh size impurities causing tur bidity and substances diss...

Page 30: ...servicing inspection repair Installation and maintenance may only be carried out by personnel authorized by the manufacturer who are capable of fulfilling the instructions given in the operating inst...

Page 31: ...dition In derogation of the International System of Units SI Syst me International d Unit s the following units are used Attention This symbol refers to a point which must be observed for reliable ope...

Page 32: ...ter is suitable for use in cold drinking water water of the munic ipal water supply up to a maximum water temperature of 30 C 86 F It is abso lutely essential that the manufacturer supplier will be co...

Page 33: ...IN 1988 ff and DIN EN 1717 They are tested by the DVGW Deutsche Vereinigung des Gas und Wasserfaches e V technical scientific association for the gas and waterindustries inaccordancewiththerequirement...

Page 34: ...o be intended use Additional dangers exist in case of non intended use and failure to observe the danger symbols and safety information Themanufacturer supplierarenotliableforanylossesordamageresultin...

Page 35: ...and the safety information can not only result in dan gers for persons but can also harm the environment and the unit 4 4 WATER PRESSURE The water pressure should be between 1 5 bar and 10 bar In the...

Page 36: ...r s specifications In addition this may also result in short circuits if these electrical devices equipment being connected to the electrical power supply In the event of such cases persons are at ris...

Page 37: ...downstream of the cartridge filter Thus the water supply can be interrupted during installation maintenance repair and malfunction of the cartridge fil ter Floodings and serious water damage to house...

Page 38: ...tion dimensions Installation dimensions CLEAR 2 0 K CLEAR 2 0 K 1 CLEAR 2 0 K 1 A Fitting length with screw connection 180 195 230 A Fitting length without screw connection 100 100 110 B Unit width 12...

Page 39: ...hanical damage can result the pipe may burst or the built in rotary flange can break This can result in major water damage In this case persons close to the cartridge filter are exposed to a health ri...

Page 40: ...alternately with an Allen key see fig 6 III The pipes must be able to safely support the cartridge filter Otherwise mechanical damage or fractures bursts can occur in the pipes This can result in majo...

Page 41: ...n The retained dirt can be seen from the outside through the transparent filter bowl As long as the cover of the filter bell is closed it serves as UV protection The filtered water then leaves the car...

Page 42: ...filter Detach the front cover to the front and subsequently detach the UV protection cover Unscrew all the four cylinder screws M6 130 with an Allen key Pull the filter bowl off in downward direction...

Page 43: ...43 Fig 8 Screen replacement I 1 2 3 II 4 III 5 6 IV 7 8 9 10...

Page 44: ...thus a large flow resistance can result Experience shows that increased dirt is deposited during the initial running peri od If so the screen has to be replaced more often than usual Failure to replac...

Page 45: ...RTS Before carrying out any work on the cartridge filter which extends beyond pure operational control the cartridge filter must be depressurised Only original spare parts are to be used Arbitrary mod...

Page 46: ...dis charged into the drinking water when the cartridge filter is switched back on The health of persons who drink dirty water is at risk Store the cartridge filter in frost free conditions Frost can c...

Page 47: ...A maintenance contract is the best way to ensure a good operating function beyond the warranty period Wherever possible the regular servicing work and supply with consumables and wearing materials et...

Page 48: ...w rate falls Screen is blocked Replace the screen Leaks in the cartridge filter Inform the fitter or nearest cus tomer service centre Filter bowl becomes turbid Cartridge filter has been exposed to hi...

Page 49: ...49 10 SPARE PARTS Fig 9 Spare parts CLEAR 2 0 K 1 9 12 13 14 15 1 3 7 11 8 9 2 10 6 B C...

Page 50: ...bowl and flange consisting of items 13 14 1 2080158 1 Cylinder screw M6 130 4 1650134 2 Cover 1 3 O ring 52 3 5 1 6 Front cover complete 1 7 Plug for manometer complete 1 8 Basic housing 1 9 Profiled...

Page 51: ...e effects of water pipe bursts leakages defects on the do mestic water installation and unusually high water consumption Detects leaking taps and valves Technical data CLEAR 2 0 K CLEAR 2 0 K 1 CLEAR...

Page 52: ...u with information Germany T 49 0 7195 692 0 France T 33 0 3 88 65 93 94 A servicing agreement is the best way to ensure a good operating function beyond the warranty period We strongly recommend you...

Page 53: ...53 Notes...

Page 54: ...1 4 4 CI NIENIE WODY 61 4 5 PRZYRZ DY URZ DZENIA ELEKTRYCZNE 62 5 WYMAGANIA W STOSUNKU DO MIEJSCA MONTA U 63 6 INSTALACJA 64 6 1 WYMIARY MONTA OWE 64 6 2 MONTA FLANSZY MONTA OWEJ 65 6 3 MONTA FILTRA 6...

Page 55: ...86 F Oddziela on od wody poprzez filtracj na sicie grubo i drobnoziarniste cz stki wi ksze lub r wne red nicy oczek sita filtra Z wody nie zostaj odfiltrowane drobinki mniejsze od stosowanej rednicy o...

Page 56: ...wa Prace w ramach instalacji i utrzymania ruchu mog przeprowadza wy cznie pracownicy upowa nieni przez producenta kt rzy s w stanie wype ni zalecenia wskazane w instrukcji monta u i eksploatacji oraz...

Page 57: ...ze w pe ni czytelne Odmiennie od mi dzynarodowego uk adu jednostek miar SI Syst me International d Unit s stosowane s nast puj ce jednostki Uwaga Ten znak oznacza punkt kt ry musi koniecznie by przest...

Page 58: ...ne rekla macje nie b d uwzgl dniane Filtr jest przystosowany do u ytku z zimn wod pitn woda wodoci gowa do temperatury wody i otoczenia na poziomie maks 30 C 86 F Przed monta em do innych medi w ni d...

Page 59: ...7 Zosta y skontrolowane przez DVGW Deutsche Vereinigung des Gas und Wasserfaches e V Technisch wissenschaftlicher Verein Nie miecki Zwi zek Bran y Gazowniczej i Wodnej zarejestrowane stowarzyszenie te...

Page 60: ...boli bezpiecze stwa lub nie przestrzegania przepis w bezpiecze stwa wyst puj dodatkowe zagro enia Za szkody wynikaj ce z tego tytu u producent dostawca nie odpowiada Ryzyko ponosi wy cznie u ytkownik...

Page 61: ...nieniniejszejinstrukcjieksploatacjiorazzawartychwniejprzepis wbezpiecze stwamo e by niebezpieczne dla os b rodowiska naturalnego oraz filtra 4 4 CI NIENIE WODY Ci nienie wody musi waha si w przedziale...

Page 62: ...przyrz dy urz dzeniaelektrycznes pod czonedozasilaniaelektrycznego mo eponadtodoj do zwarcia W takim przypadku istnieje niebezpiecze stwo pora enia u ytkownik w pr dem elektrycznym Przyrz dy urz dzeni...

Page 63: ...m uderzeniom Przed i za filtrem musi by zainstalowany zaw r odcinaj cy Umo liwia on odci cie dop ywu wody podczas instalacji konserwacji naprawy i awarii filtra Pozwala to unikn zalania lub wi kszych...

Page 64: ...ymiary monta owe Wymiar monta owy CLEAR 2 0 K CLEAR 2 0 K 1 CLEAR 2 0 K 1 A D ugo monta owa ze rubunkami 180 195 230 A D ugo monta owa bez rubunk w 100 100 110 B Szeroko urz dzenia 124 124 124 C Wysok...

Page 65: ...m razie mo e doj do uszkodzenia mechanicznego a nawet do p kni cia ruroci gu lub flan szy Skutkiem tego mog by du e szkody spowodowane przez wod Zdrowie os b przebywaj cych w po bli u filtra jest w ta...

Page 66: ...y jestfiltr musi wytrzyma ci ar filtra W przeciwnym razie mo e doj do uszko dzenia mechanicznego ruroci gu a nawet do jego p kni cia Skutkiem tego mog by du e szkody spowo dowane przez wod Zdrowie os...

Page 67: ...tracyjnym Przywieraj ce zabrudzenia widoczne s z zewn trz przez prze roczyst czasz filtra Os ona czaszy filtra s u y jako os ona UV Nast pnie przefiltrowana woda opuszcza filtr ponownie przez flansz m...

Page 68: ...em Przedni pokryw ci gn do przodu i usun os on czaszy filtra Kluczem imbusowym odkr ci cztery ruby cylindryczne M6 130 Czasz filtra wyci gn na d i usun stary wk ad filtracyjny razem z uszczelk Nowy wk...

Page 69: ...69 Rys 8 Wymiana wk adu filtracyjnego I 1 2 3 II 4 III 5 6 IV 7 8 9 10...

Page 70: ...filtracyj nym jak i wi kszego oporu przep ywu Z praktyki wynika e w nowych instalacjach w pocz tkowym okresie nast puje silniejsze odk adanie si zabrudze W takim przypadku nale y wymienia wk ad filtr...

Page 71: ...MIENNE Przed rozpocz ciem prac przy filtrze wykraczaj cych poza zwyk obs ug eks ploatacyjn filtr nie mo e znajdowa si pod ci nieniem Wolno stosowa wy cznie oryginalne cz ci zamienne Samodzielna przebu...

Page 72: ...abrudzenia Zabrudzenia te mog przy ponownym uruchomieniu filtra zetkn si z wod pitn i przenikn do niej Zdrowie os b kt re spo yj zanie czyszczon wod mo e by zagro one Filtr przechowywa w miejscu bezpi...

Page 73: ...to uregulowane przez norm DIN EN 806 5 Umowa o konserwacj zapewnia sprawno eksploatacyjn r wnie poza okresem gwarancyjnym Nale y d y do tego aby za regularne prace konserwacyjne i uzupe nianie materi...

Page 74: ...zyna Rozwi zanie Przep yw wody jest coraz mniej szy Zatkany wk ad filtracyjny Wymieni wk ad filtracyjny Nieszczelno filtra Poinformowa instalatora lub naj bli szy serwis Zm tnienie czaszy filtra Filtr...

Page 75: ...75 10 CZ CI ZAMIENNE Rys 9 Cz ci zamienne CLEAR 2 0 K 1 9 12 13 14 15 1 3 7 11 8 9 2 10 6 B C...

Page 76: ...si z poz 13 14 1 2080158 1 Wkr t z bem walcowym M6 130 4 1650134 2 Pokrywa 1 3 O ring 52 3 5 1 6 Pokrywa przednia komplet 1 7 Zatyczka do manometru komplet 1 8 Podstawowa obudowa 1 9 Profilowana uszc...

Page 77: ...r wyciek w wad w filtrze i wyj tkowo wysokim zu yciu wo dy Wykrywa ciekn ce krany i armatury Dane techniczne CLEAR 2 0 K CLEAR 2 0 K 1 CLEAR 2 0 K 1 rednica przy cza nominalna DN 20 DN 25 DN 32 Przep...

Page 78: ...ji Niemcy T 49 0 7195 692 0 Francja T 33 0 3 88 65 93 94 Pilnie zaleca si zawarcie umowy serwisowej na wykonywanie regularnych fachowych przegl d w aby urz dzenia uzdatniaj ce wod mog y by regularnie...

Page 79: ...79 Notatki...

Page 80: ...CONEL GmbH Margot Kalinke Str 9 80939 M nchen S mtliche Bild Ma und Ausf hrungsangaben entsprechen dem Tag der Drucklegung nderungen die dem technischen Fortschritt und der Weiter entwicklung dienen b...