background image

CDX800 DESCRIPTION

the circuit diagram of the modem is on the following pictures

.

34

Summary of Contents for CDX 800

Page 1: ...Radio data modem CDX 800 USER S GUIDE...

Page 2: ...ectors M BUS 17 2 6 5 Connection of PORT2 connectors CNT 19 2 6 6 Connection of I O connector 20 2 6 7 Power supply connector PWR 21 2 7 Antenna connection 23 2 8 Power supply 23 2 9 Ports technical s...

Page 3: ...ogram 40 6 PRODUCT DISPOSAL INFORMATIONS 40 7 COMPLAINTS PROCEDURE 41 8 WARRANTY 43 Symbols used Danger important notice which may have an influence on the user s safety or the function of the device...

Page 4: ...the communication module must not be exceeded Do not expose the communication module to extreme ambient conditions Protect the communication module against dust moisture and high temperature It is re...

Page 5: ...s program configurable and one interface for direct connection of inputs and outputs CIO for data collection and technological process management It is possible to set transfer parameters and communic...

Page 6: ...ports are linked to RJ45 connectors marked PORT1 PORT2 All user interface signals are protected against over voltage on the data cable Device with different communication protocol can be connected to...

Page 7: ...emporary switched to RS232 serial link 2 4 5 Optional hardware interface PORT2 PORT2 on the CDX 800 back panel provides for direct use of other HW interface than the standard RS232 It is due to the de...

Page 8: ...ed 24 kbps 10 TX RX Temperature range Function Storage 25 o C to 55 o C 40 o C to 85 o C Supply voltage car dashboard 10 to 30 V DC Consumption TX RX 3 W 350 mW Dimensions 30 x 90 x 102 mm moulding fi...

Page 9: ...Off no activity On transmitting on the port 1 GREEN RX1 Off no activity On receiving on the port 1 RED TX2 Off no activity On transmitting on the port 2 GREEN RX2 Off no activity On receiving on the p...

Page 10: ...800 DESCRIPTION An RJ45 CIO connector is located on the front panel of CDX 800 CIO connector is for direct input and output connections for data collection and technology control 10 Port CIO Modem sta...

Page 11: ...Ready connected to 4 V through 330 Ohm Output 5 GND GROUND signal ground 6 RXD Receive Data Output 7 CD Carrier Detect Output 8 TXD Transmit Data Input 43B43B43B43B Circuit example of the meter with...

Page 12: ...mark Description Data flow direction 1 2 3 TxRx RS485 B Input Output 4 5 6 TxRx RS485 A Input Output 7 8 Circuit example of the meter with modem CDX 800 with data length less then 10 m 12 PORT1 PORT2...

Page 13: ...nal and supply ground 2 GND Signal and supply ground 3 TxRx RS485 B Input Output 4 TxRx RS485 A Input Output 5 TxRx RS485 B Input Output 6 TxRx RS485 A Input Output 7 12V EXT External power supply 10...

Page 14: ...0m it is need to use overvoltage protection on CDX 800 modem side 14 Pin 1 SGDN Pin 2 SGND Pin 3 RS485 Pin 4 RS485 Pin 5 RS485 Pin 6 RS485 Pin 7 12V EXT Pin 8 12V EXT Modem CDX 800 SGND RS485 RS485 Me...

Page 15: ...nsmit Data Input 6 TxD Transmit Data Input 7 12V EXT External power supply 8 12V EXT External power supply ATTENTION External supply is for converter RS422 The converter must have external power suppl...

Page 16: ...more then 10 m At RS485 data cable more then 10m it is need to use over voltage protection on CDX 800 modem side 16 Pin 1 SGND Pin 2 SGND Pin 3 RxD Pin 4 RxD Pin 5 TxD Pin 6 TxD Pin 7 12V EXT Pin 8 1...

Page 17: ...TxRx M BUS A Input Output 7 12V EXT External power supply 10 8 15 6V 8 12V EXT External power supply 10 8 15 6V ATTENTION External supply is for converter M BUS The converter must have external power...

Page 18: ...then 10 m M BUS data cable more then 10m it is need to use over voltage protection on CDX 800 modem side 18 Pin 1 SGND Pin 2 SGND Pin 3 M BUS Pin 4 M BUS Pin 5 M BUS Pin 6 M BUS Pin 7 12V EXT Pin 8 12...

Page 19: ...tion Direction 1 BIN0 CNT0 Binary input counter input Input 2 BIN1 CNT1 Binary input counter input Input 3 BIN2 Binary input Input 4 BIN3 Binary input Input 5 GND Signal ground 6 OUT0 Binary output Ou...

Page 20: ...I O 3 Input Output analogue or binary input or binary output open collector Input Output 4 12V Output 12V for supply of other circuits connected directly to modem supply Output 5 GND Signal and supply...

Page 21: ...voltage 10 30 V 5 GND Negative pole of supply voltage 6 GND Negative pole of supply voltage On the power supply connector it is possible to use the signal INAC NAP230 for present AC voltage monitorin...

Page 22: ...CDX800 DESCRIPTION DC supply with backup battery without present supply monitoring 22 Modem CDL 800 CDL 400 DC Pin 1 12V Pin 2 GND Pin 3 PWRSV Pin 4 INAC...

Page 23: ...A connector on the back panel 2 8 Power supply CDX 800 requires DC supply of 10 to 30 V During reception consumption is 1 W During data sending peak consumption is 3 5 W For proper function it is nece...

Page 24: ...Max overvoltage 30 V Max total cable length 300Bd 200nF km 20 m Expansion port M BUS Name of port M BUS Power supply Voltage 10 8 15 6 V Supply power Max 30 W Environment Operating temperature 25 55 C...

Page 25: ...this module If it is necessitated external power supply of module it must be by jumper J2 and J3 connection pin 2 3 Internal power supply is evoke of connection pin 1 2 on jumper J2 and J3 Interface b...

Page 26: ...tion 2 mA Environment Operating temperature 25 55 C Storage temperature 40 85 C Standards Emission EN 55022 B Immunity ETS 300 342 Safety EN 60950 Isolation EN 60747 Inputs outputs 2x counter Max 100...

Page 27: ...connected to any of the three RS232 serial ports and the service SW runs on the connected PC it is possible to execute not only all the needed radio modem settings but service interventions in the ra...

Page 28: ...r supply connector for a power supply cable 2 Three RJ45 connectors to complete the data cable by snapping to the cable 3 Compliance certificate 4 Complaint procedure 5 Warranty 2 13 Additional access...

Page 29: ...ion port RS485 RS422 Expansion port M BUS Expansion port CNT 4 CIO modules CIO ReO 2 expansion module with relay output CIO OpI 2 expansion module with binary input CIO AnI 2 expansion module with ana...

Page 30: ...CDX800 DESCRIPTION 2 14 Assembly procedure The CDX 800 module is designed as a standard for 1 Assembly to a panel using through holes 30 Through holes for montage...

Page 31: ...CDX800 DESCRIPTION 2 DIN 35 mm rail assembly using plastic grips 3 To be put on a worktop 31...

Page 32: ...ts it is possible to mount modems to the switch board which it doesn t need to have no examination immunity or issues in connection with EMC ac cording to EN 60439 1 ed 2 For compliance of EN 60439 1...

Page 33: ...fit over voltage protectors surge suppressors with data cables they mustn t carry cables with reticular tension 230 V 50 Hz all signals to sensors must be twisted pairs sufficient space must be left...

Page 34: ...CDX800 DESCRIPTION the circuit diagram of the modem is on the following pictures 34...

Page 35: ...W 1x RS232 10 30 V 2 17 PORT2 marking Trademark Type name Power supply Expansion port RS232 XC 232 Internal from module CDX 800 Expansion port RS485 RS422 XC 485 422 Internal External Expansion port M...

Page 36: ...the data form to a remote location of a data network 3 2 1 Analogue input Every 100 msec the voltage value of the analogue input is read converted to a digital decabit value and adjusted by the calibr...

Page 37: ...lue is recorded in CDX 800 statistics as a failure and rise of supply voltage 230 V Beware it is impossible to connect 230V supply voltage directly to the input Signal name Measuring range V Resoluti...

Page 38: ...same time protect the inputs from interference and over voltage Similarly serial electric circuits should be mounted to control power parts of the user device as the transistor with open collector is...

Page 39: ...tage by suppressors and against the long time one by a reverse fuse Insulation capacity of the galvanic part is 5000 V Input DC voltage 3 to 30 V Input AC voltage 3 to 30 V rms Input AC voltage high v...

Page 40: ...twork Protocol 5 3 Program RADWIN this software provides for creation installation and administration of data networks 6 Product disposal informations The WEEE Waste Electrical and Electronic Equipmen...

Page 41: ...data saved in the subject of the complaint The customer is obliged to clarify the defect or how it is displayed and what claim he intends to register Processing the complaint The vendor shall provide...

Page 42: ...he she pays the demonstrable cost of expert assessment The guarantee does not cover defects due to 1 Mechanical damage fall and the like 2 Use of inadequate or not recommended sources and other access...

Page 43: ...WARRANTY 8 Warranty Device type Serial number Guarantee period months Vendor Date of purchase Seal of the vendor 43...

Page 44: ...ration Complaint protocol number Date of reception of the device in repair shop Date of finished repair Number of repair sheet Warranty repair YES NO YES NO YES NO YES NO YES NO New serial number of t...

Reviews: